Split Solar Water Heater Controller SR868C8
Intelligent Solar Water Heater controller,anti-dry heating fctn SR868C8,Three Sensor Input,4 relay outputs for circulation pumps or 3-way
electromagtenic valves,Preferred Shipping Methods Available.
1.Introduce:
1 collector array1 storage tank 1 pump and auxiliary heating Description: The solar circuit pump (R1) is switched on as soon as the switch-on temperature difference (Ton) between the collector array (T1) and the storage tank (T2) is reached. If the temperature difference between the collector array (T1) and storage tank (T2) drops below the switch-off temperature difference (Toff), or the temperature of storage tank (T3) reaches the preset maximum storage temperature, then the solar circuit pump ( R1) is switched off. Back-up heating by auxiliary boiler (detailed see paragraph 4.3): Within the preset time section of back-up heating, if the temperature T3 is below the switch-on temperature, then the circulation pump ( H1) of back-up heating is triggered, when T3 is heated to the switch-off temperature, circulation pump H1 of back-up heating is ceased
2.Technical Data
1.Specification: SR868C8
2.Appearance of controller: 120mm*120mm*18mm
3.Power supply: AC230V+-10%
4.Power consumption: < 3W
5.Accuracy of temperature: +-2oC
measuring
6.Range of collector: -10-220oC
7.temperature measuring
Range of tank: 0-110oC
8.temperature measuring
Suitable power of pump: three pumps, <= 600W
9.Suitable power of : power<= 1500W
10.electrical heater
Inputs: 1 * Pt1000 sensor (<=500oC) for collector (silicon cable<=280oC),
2 * NTC10K, B3950 sensor (<=135oC) for tank, (PVC cable <=105oC),
Outputs : 3 relays, for circulation pumps or 3-way electromagnetic valve
1 relay for electrical heater
11.Ambient temperature: -10-50 oC
12.Water proof grade : IP40
3.Main Functions
1.Main menu DT O & DT F Temperature difference function
2.Main menu-THET timing heating
3.TEMP Temperature main menu
4.EM Emergency collector temperature
(emergency switch-off temperature of collector)
5.CMX Maximum limited collector temperature (collector cooling function)
6.CMN low temperature protection of collector
7.CFR frost protection of collector
8.SMX Maximum temperature of tank
9.REC Tank re-cooling function
10.Celsius and Fahrenheit temperature transferring
11.FUN Auxiliary function
12.DVWG Anti-Legionella function
13.CIRC Temperature controlled hot water circulation pump
14.BYPR High temperature by-pass function
(tank temperature automatically adjusting)
15. HND Manual mode
16.PASS Password setting
17.LOAD Recovery to factory setting
18.ON/OFF button
19.Holiday function
20.Manual heating
21.Temperature query function
22.Memory Protection
23.Anti-dry heating Protection
24.Screen protection