  • Detects all CFC, HFC, and HCFC non-flammable refrigerants including R12, R22, R134a, R404a, R410a, R502, R507 and many others
  • Ultra-sensitive detection as low as 0.006 oz/yr
  • Dual power sources include rechargeable battery and external DC powered wall adapter (included)
  • Visual sensor calibration system (with included reference leak bottle)
  • Pinpoints small, medium and large leaks quickly and accurately
  • Headphone port allows for optional headset for use in high-noise environments
  • Detects: All CFC, HFC, and HCFC non-flammable refrigerants including: R12, R22, R134a, R404a, R410a, R502, R507 and many others
  • Sensing Element: Positive Ion Emission Heated Diode
  • Sensitivity: 0.006 oz/yr (stationary) | 0.1 oz/yr (moving probe per SAE J2791)
  • Sensor Life: 1 year (typical)**
  • Warm-Up Time: Approx. 2 minutes
  • Response Time: 1 second
  • Accuracy: Exceeds SAE J1627
  • Operating Temperature: 32°F to 104°F (0°C to 40°C)
  • Flow Rate: 90 cc/min (typical)^
  • Auto-Background Adjust: Yes, automatic mode only
  • Leak Indicators: Visible LED at probe tip and audible buzzer (with or without optional headphones)
  • Probe Length: Flexible 4.5 ft. (1.37 m) with built-in filter
  • Dimensions: 10.5”l x 8.3”w x 5.4” h (26.7 cm x 21.1 cm x 13.7 cm)
  • Weight: Approx. 5.1 lb. (2.3 kg)
  • Agency Listings: UL file SA9717, SAE J1627, CE-Mark
  • Power:
    • 12 VDC - internal rechargeable sealed lead acid battery (included)
    • 100-240 VAC wall adapter/universal battery charger to charge or run continuously (included)
  • Battery Life: 3 hours (typical)
  • Warranty: 3 years
    *does not cover sensors, filters, reference leaks, airflow balls, lamps, batteries or probe tips
**Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life. ^Flow rate value is for small leak setting. Consult manual for more details on specifications


 

Store policies 

Climate Doctors offers products that may require professional installation. Climate Doctors recommends hiring a HVAC/R professional trained in the service and repair of HVAC/R appliances. Repair parts sold by Climate Doctors may require specialized tools and/or procedures for safe and reliable operation of certain systems. Buyer(s) specifically holds Climate Doctors harmless for injury, property damage, or other losses associated with the use of items purchased from Climate Doctors. It is not the intention of Climate Doctors to encourage the servicing of HVAC/R appliances by untrained personnel, rather to "allow the public to purchase the necessary parts directly" for use by trained and/or licensed professionals.


Payment Payment
  • We accept PayPal , wire transfers, and all major credit cards (Visa, MasterCard, American Express and Discover), as well as debit cards.
  • For assistance with payment questions, quotes, and volume discounts, contact our Customer Support during normal business hours.
  • **Please note that ClimateDoctors is required to charge 7.63% sales tax for shipments to Colorado addresses.

Shipping
  • We combine shipping when possible.
  • All orders usually ship within 1-2 business days if placed before 3 p.m. EST. Shipment days are Monday through Friday.
  • Tracking information is sent to you automatically at the time of shipment and is always available if needed.
  • All orders are inspected prior to shipment and are insured against loss or damage in transit.
  • All international customers are responsible for and duties and broker fees.
  • Standard US shipping rates do not include Alaska and Hawaii. Please contact us for a shipping quote to these destinations.

 


Customer Service
Climate Doctors is committed to providing you with the best customer service and HVAC/R product knowledge in the industry. Our friendly Parts Experts are ready to answer your questions or assist you in any way.

Sales or Product Specialists are available: Monday-Friday: 9:00 a.m. to 5:00 p.m. CST.

Returns
  • You MUST call and obtain a Return Authorization Number prior to returning any product or the package will be refused.
  • Replacement parts, equipment and chemicals are all sales final, returns or exchanges are not accepted. Electrical heating and A/C parts may not returned or exchanged.
  • Tools and meters are exchange only within 3 days of receipt. All other items must be returned within 14 days of our shipping date.
  • Merchandise must be returned in resalable condition: complete in original packaging, unused, and free from damage.
  • All returns are subject to a 20% processing/restocking fee. Original shipping fees and return shipping fees are the buyer’s responsibility and are non-refundable. If it was FREE shipping, the amount it cost us to ship it will be deducted from your refund.
  • Please contact us if you have any questions or need assistance with your purchase. Phone 719-941-9930