NPUT DATA | 10.0-1 UNI | 11.4-1 UNI | 10.0-3 UNI DELTA | 11.4-3 UNI DELTA | 12.0-3 WYE277 |
---|---|---|---|---|---|
Recommended PV-Power (kWp) | 5.50 - 11.50 | 9.70 - 13.10 | 8.50 - 11.50 | 9.70 - 13.10 | 10.20 - 13.80 |
Nominal Input Current | 27.6 A | 31.4 A | 27.6 A | 31.4 A | 33.1 A |
Max. Usable Input Current | 46.7 A | 53.3 A | 46.7 A | 53.3 A | 56.1 A |
MPPT - Voltage Range | 230 - 500 V | ||||
DC Startup | 260 V | ||||
Max. Input Voltage | 600 V | ||||
Admissable Conductor Size (DC) | No. 14 to 6 AWG. For larger wire, use Fronius connecting distributor. | ||||
Max. Current per DC Input Terminal | 0 Amps. For higher input current, use Fronius connecting distributor. |
OUTPUT DATA | 10.0-1 UNI | 11.4-1 UNI | 10.0-3 UNI DELTA | 11.4-3 UNI DELTA | 12.0-3 WYE277 |
---|---|---|---|---|---|
Nominal Output Power | 9,995 W | 11,400 W | 9,995 W | 11,400 W | 12,000 W |
Max. Continuous Output Power | 9.995 W | 11,400 W | 9,995 W | 11,400 W | 12,000 W |
AC Output Voltage | 208 / 240 / 277 | 208 / 240 / 277 | 208 / 240 | 208 / 240 | 480 / 277 WYE |
Number of Phases | 1 | 1 | 3 | 3 | 3 |
Admissable Conductor Size (AC) | No. 14 - 4 AWG | ||||
Max. Continuous Utility Backfeed Current | 0A | ||||
Nominal Output Frequency | 60 Hz | ||||
Operating Frequency Range | 59.3 - 60.5 Hz | ||||
Total Harmonic Distortion | < 3 % | ||||
Power Factor | 0.85 - 1 ind. / cap. |
GENERAL DATA | 10.0-1 UNI | 11.4-1 UNI | 10.0-3 UNI DELTA | 11.4-3 UNI DELTA | 12.0-3 WYE277 |
---|---|---|---|---|---|
Max. Efficiency | 96.2 | ||||
Unit Dimensions (W x H x D) | 17.1 x 49.7 x 9.9 in. | ||||
CEC Efficiency 208 V | 95.0 % | 95.0 % | 95.5 % | 95.0 % | n.a. |
240 V | 95.5 % | 95.5 % | 95.5 % | 96.0 % | n.a. |
277 V | 96.0 % | 96.0 % | n.a. | n.a. | n.a. |
Consumption in Standby (Night) | < 1.5 W | ||||
Consumption During Operation | 20 W | ||||
Cooling | Controlled forced ventilation, variable speed fan | ||||
Enclosure Type | NEMA 3R | ||||
Power Stack Weight | 84 lbs. (38 kg) | ||||
Wiring Compartment Weight | 26 lbs. (12 kg) | ||||
Admissable Ambient Operating Temperature | -13o F...+131o F (-25o C...+55o C) | ||||
Advanced Grid Features | Active and reactive power control, low voltage ride-through | ||||
Compliance | UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 1699B-2013, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2011) California Solar Initiative - Program Handbook - Appendix C: Inverter Integral 5% Meter Performance Specification |
EFFICIENCY | 10.0-1 UNI | 11.4-1 UNI | 10.0-3 UNI DELTA | 11.4-3 UNI DELTA | 12.0-3 WYE277 |
---|---|---|---|---|---|
Operating AC Voltage Range 208 V | 183 - 229 V (-12 / +10%) | ||||
240 V | 211 - 269 V (-12 / +10%) | ||||
277 V | 344 - 305 V (-12 / +10%) | ||||
Max. Continuous Output Current 208 V | 48.1 A | 54.8 A | 27.7 A* | 31.6 A* | n.a. |
240 V | 41.7 A | 47.5 A | 24.0 A* | 27.4 A* | n.a. |
277 V | 36.1 A | 41.2 A | n.a. | n.a. | 14.4 A* |
PROTECTIVE EQUIPMENT | 10.0-1 UNI | 11.4-1 UNI | 10.0-3 UNI DELTA | 11.4-3 UNI DELTA | 12.0-3 WYE277 |
---|---|---|---|---|---|
Ground Fault Protection | Internal GFDI (Ground Fault Detector/Interrupter) in accordance with UL 1741-2010 and NEC Art. 690 | ||||
DC Reverse Polarity Protection | Internal Diode | ||||
Islanding Protection | Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC | ||||
Over Temperature Protection | Output power derating / active cooling | ||||
Arc-Fault Circuit Protection | Internal AFCI (Arc-Fault Circuit Interrupter); in accordance with UL 1699 Outline of Investigation for Photovoltaic (PV) DC Arc-Fault Circuit Protection (Issue Number 2, January 14, 2013) |