SMA Sunny Boy 4000-US-10 Grid-Tie String Inverter 208/240V
SMA Sunny Boy SB 4000-US-10 Grid-Tie String Inverter 208/240V
Note: No AFCI (can purchase AFCI device separately)
- Characteristics
- ManufacturerSMA
- ModelSB 4000US-10
- Rated Power Output [W]4000
- Length [mm (in)]350 mm (14 in)
- Width [mm (in)]450 mm (18 in)
- Depth [mm (in)]235 mm (9 in)
- Weight [kg (lb)]38 kg (84 lb)
- Warranty [Years]10
- Surge/Lightning Protection
- Maximum Volts [Vdc]
- Discharge Current [kA]
- Nominal DC Voltage Range [Vdc]
- Nominal AC Voltage [Vac]
- Modules
- Tier Level
- Lower Output Tolerance [-%]
- Upper Output Tolerance [%]
- Only suitable for transformer invertersNo
- Pmax - Maximum Power (STC) [W]
- Voc - Open Circuit Voltage (STC) [V]
- Isc - Short Circuit Current (STC) [A]
- Vmpp-Voltage at Maximum Power (STC) [V]
- Impp-Current at Maximum Power (STC) [A]
- Cell Efficiency (STC) [%]
- Module Efficiency (STC) [%]
- Pmax - Maximum Power (NOCT) [W]
- Voc - Open Circuit Voltage (NOCT) [V]
- Isc - Short Circuit Current (NOCT) [A]
- Impp-Current at Maximum Power (NOCT) [A]
- Vmpp-Voltage at Maximum Power (NOCT) [V]
- Cell Efficiency (NOCT) [%]
- Module Efficiency (NOCT) [%]
- Nominal Operating Cell Temperature NOCT
- Maximum System Voltage [V]
- Series Fuse Rating [A]
- Maximum Reverse Current [A]
- Cell Technology
- Solar Cell's Country of Origin
- Solar Cell Size
- Number of Cells (Pieces)
- Number of Bypass Diodes
- Frame Color
- Back Cover
- Junction Box
- Output Cables
- Connector
- Hail Safety Impact Velocity [mm at m/s]
- Fire Safety Classification (IEC 61730)
- Static Load Wind / Snow [Pa]
- Normal Operating Cell Temperature (NOCT)
- Temperature Coefficients of P [%/°C]
- Temperature Coefficients of V (Uoc)
- Temperature Coefficients of I (Isc)
- Storage Temperature [°C]
- Packaging Configuration
- Loading Capacity (40 ft. Container)
- 80% Power Output Warranty Period
- 90% Power Output Warranty Period
- Workmanship Warranty Period
- CSI Listed
- Inverters
- Inverter TypeGrid-Tie String Inverter
- Maximum/Peak Efficiency [%]208V:96.5%/ 240V:96.8%
- CEC weighted efficiency [%]
- Transformer / TransformerlessTransformer
- DC Power Rating [W]4000
- Nom. DC Voltage [V]310
- Max. Input Power [W]4200
- Max. Input Voltage [V]600
- Max. Input Current [A]
- MPP voltage range [V]208V:220-480V / 240V:250-480V
- Min. DC voltage / start voltage [V]208V:220/285V; 240V:250/285V
- Feed-in From [W]
- Number of DC String Inputs (Inlets)4
- Number of MPP Trackers1
- Max. Input Power per MPPT [W]
- Max. Input Voltage per MPPT [V]
- Max. Input Current per MPPT [A]
- Voltage Lower Limit for MPP Range [V]
- Voltage Upper Limit for MPP Range [V]208V,240V: 480V
- DC Disconnection TypeFused
- Reverse-Polarity ProtectionNo
- Ground-Fault Isolation Detection
- AC Power Rating [W]3500
- Nominal AC Power [W]
- Max. AC Power [W]3500
- AC voltage range [V]208V:183-229V / 240V:211-264V
- AC grid frequency [Hz]60
- Max. output current [A]17 A
- Nominal AC Voltage [V]
- Maximum AC Voltage Range [V]208V: 229V/ 240V: 264V
- Nominal AC Frequency [Hz], range [Hz-Hz]
- Max. AC Line Current [A]
- AC Connection Type
- AC Current Distortion [THD%]
- AC DisconnectYes
- AC Input Wire Gauge Range [AWG]
- Max Microinverters Units per xA string
- Sleep (Night) Consumption [W].1
- Standby Consumption [W]
- CSI-Approved Built-in MeterYes
- NEMA Enclosure RatingNEMA 3R
- Cooling MethodOptiCool
- Ambient Temperature Range [°C(°F)]-25°C - 45°C (-13°F - 113°F)
- Operating Humidity [%]
- Operating Altitude [ft/m]
- DisplayText Line
- CommunicationRS485/Bluetooth optional
- Basic Warranty [Years]10
- Warranty Extension Options [Years]15, 20
- Safety and EMC Standard
- Grid StandardIEEE1547
- CompliancesUL1741 (Second Ed.), UL1998, UL1699B, IEEE 1547, FCC Part 15 (Class A & B), CSA C22.2 No. 107.1-2001
- AC grid range [Hz]59.3-60.5 Hz
- Max. recommended PV power (@ module STC)208V: 4375W/ 240V: 5000W
- Fuses and Holders
- Amps [A]
- Data Logers
- Bluetooth (BT)No
- WiFi (wireless LAN)No
- Powermanagement (PM+)No
- Powermanagement (PM+) / GPRSNo
- Powermanagement (PM+) / WiFiNo
- GPRSNo
- Central inverter SCB and SMBNo
- Max. no. inverters
- Communication interface
- Inverter mixed operationNo
- Measured max. plant size [kWp]
- Max. cable length
- String monitoring-depends on inv. modelNo
- Inverter failureNo
- Performance monitoring for each inverterNo
- Status/fault monitoringNo
- Connection to sensor systemNo
- Connection to Sensor BasicNo
- Email and SMS alarmNo
- Local alarm (pot. free contact)No
- Yield forecastingNo
- Degradation calculationNo
- Connection to digital meter readerNo
- Integrated webserverNo
- Graphic visualisation - local PCNo
- Graphic visualisation - USB stickNo
- Graphic visualisation - internetNo
- LED status displayNo
- Operation on deviceNo
- Large display RS485/S0 pulseNo
- Sâ‚€ in/out
- Ethernet networkNo
- USB stickNo
- Analogue modem / GPRS(GSM)No
- Potential-free contact (relay)No
- Alarm contact (anti-theft)No
- Mains voltage / device voltage [Vac/Vdc]
- Power consumption [W]
- Ambient Temperature [°C(°F)]
- Assembly
- Protection class for logger
- Connection to Solar-LogTM WEBNo
- Multilingual (DE, EN, ES, FR, IT, NL)No
- Memory
- Connectors
- Pre-configured (p), Configurable (c)
- Test Specifications
- LockableNo
- Protection Type Connected / Disconnected
- Approved Temperature Range [°C]
- Rated Current, Specified Cable Cross-sec
- Contact Resistance [mΩ]
- Max. System DC Voltage [V]
- Protection Class
- Contact Material
- Plug Face is Similar to
- Combinable w original type confirmed by
- Measurements (length x cross-section)
- Combiners
- Usable Cable Cross-section
- Number of Breakers
- Number of Fuse Holders
- Combiner Voltage Rating (VDC)
- Combiner Maximum DC Current (A)
- Max. Input Short Cir. Current/String [A]
- Maximum Continuous Current (A)
- Max. Input Current Per String (A)
- Combiner Maximum Voltage (VDC)
- Combiner Positive Output Wire Size (mm2)
- Output Wire Size (mm2)
- Max. Positive Input Wire Size (mm2)
- Max. Negative Input Wire Size (mm2)
- Combiner Negative Output Wire Size (mm2)
- Combiner Input Wire Size (mm2)
- Combiner Enclosure Rating
- Combiner Maximum Input Fuse Rating (A)
- Combiner Operating Temperature (CËš)
- Cables
- Reel Length (Imperial)
- Cable (Wire) Size [mm² (AWG)]
- Jacket Color
- Cable Conductor Material
- Cable Voltage Rating [V]
- Breakers
- Circuit Breaker Amps [A]
- Poles
- AC Voltage Rating [Vac]
- DC Voltage Rating [Vdc]
- FusedNo