Complete brand new old stock 10.0KW Fronius / Sunpower UNI  inverter consisting of 2 units with factory warranty.

We have a few more of these and will give you a deal if you buy a full pallet ( 4 units ) contact us for a quote !


Many people here on Ebay offer just the inverter, or just the disconnect/CPU, in both cases they are pretty useless without the other half, they are not interchangeable between types !!

This is a matched set of a  CPU/Disconnect , and the actual inverter unit that goes on top of the disconnect.

THIS IS A  UNI inverter that will work  ON YOUR 240V HOME CONNECTION !!!  ( and also on 208V or 277V )

More than 1 set available,  buy the best for less !

WE BUY, SELL AND PROFESSIONALLY REPAIR ALL SORTS OF SOLAR INVERTERS, FEEL FREE TO CONTACT ME IF YOU HAVE any quantity WORKING or DEFECTIVE INVERTERS or PARTS FOR SALEAs always, email me at gmail with questions!!     Hanssmitd at Gmail

Technical Data


INPUT DATA10.0-1 UNI11.4-1 UNI10.0-3 UNI DELTA11.4-3 UNI DELTA12.0-3 WYE277
Recommended PV-Power (kWp)5.50 - 11.509.70 - 13.108.50 - 11.509.70 - 13.1010.20 - 13.80
Nominal Input Current27.6 A31.4 A27.6 A31.4 A33.1 A
Max. Usable Input Current46.7 A53.3 A46.7 A53.3 A56.1 A
MPPT - Voltage Range230 - 500 V
DC Startup260 V
Max. Input Voltage600 V
Admissable Conductor Size (DC)No. 14 to 6 AWG. For larger wire, use Fronius connecting distributor.
Max. Current per DC Input Terminal0 Amps. For higher input current, use Fronius connecting distributor.
OUTPUT DATA10.0-1  UNI11.4-1 UNI10.0-3 UNI DELTA11.4-3 UNI DELTA12.0-3 WYE277
Nominal Output Power9,995 W11,400 W9,995 W11,400 W12,000 W
Max. Continuous Output Power9.995 W11,400 W9,995 W11,400 W 12,000 W
AC Output Voltage208 / 240 / 277208 / 240 / 277208 / 240208 / 240480 / 277 WYE
Number of Phases11333
Admissable Conductor Size (AC)No. 14 - 4 AWG
Max. Continuous Utility Backfeed Current0A
Nominal Output Frequency60 Hz
Operating Frequency Range59.3 - 60.5 Hz
Total Harmonic Distortion< 3 %
Power Factor0.85 - 1 ind. / cap.
GENERAL DATA10.0-1 UNI11.4-1 UNI10.0-3 UNI DELTA11.4-3 UNI DELTA12.0-3 WYE277
Max. Efficiency96.2
Unit Dimensions (W x H x D)17.1 x 49.7 x 9.9 in.
CEC Efficiency                   208 V95.0 %95.0 %95.5 %95.0 %n.a.
                                              240 V95.5 %95.5 %95.5 %96.0 %n.a.
                                              277 V96.0 %96.0 %n.a.n.a.n.a.
Consumption in Standby (Night)< 1.5 W
Consumption During Operation20 W
CoolingControlled forced ventilation, variable speed fan
Enclosure TypeNEMA 3R
Power Stack Weight84 lbs. (38 kg)
Wiring Compartment Weight26 lbs. (12 kg)
Admissable Ambient Operating Temperature-13o F...+131o F (-25o C...+55o C)
Advanced Grid FeaturesActive and reactive power control, low voltage ride-through
ComplianceUL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 1699B-2013, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2011) California Solar Initiative - Program Handbook - Appendix C: Inverter Integral 5% Meter Performance Specification
EFFICIENCY10.0-1 UNI11.4-1 UNI10.0-3 UNI DELTA11.4-3 UNI DELTA12.0-3 WYE277
Operating AC Voltage Range         208 V183 - 229 V (-12 / +10%)
                                                              240 V211 - 269 V (-12 / +10%)
                                                              277 V344 - 305 V (-12 / +10%)
Max. Continuous Output Current 208 V48.1 A54.8 A27.7 A*31.6 A*n.a.
                                                             240 V41.7 A47.5 A24.0 A*27.4 A*n.a.
                                                             277 V36.1 A41.2 An.a.n.a.14.4 A*
PROTECTIVE EQUIPMENT10.0-1 UNI11.4-1 UNI10.0-3 UNI DELTA11.4-3 UNI DELTA12.0-3 WYE277
Ground Fault ProtectionInternal GFDI (Ground Fault Detector/Interrupter) in accordance with UL 1741-2010 and NEC Art. 690
DC Reverse Polarity ProtectionInternal Diode
Islanding ProtectionInternal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC
Over Temperature ProtectionOutput power derating / active cooling
Arc-Fault Circuit ProtectionInternal AFCI (Arc-Fault Circuit Interrupter); in accordance with UL 1699 Outline of Investigation for Photovoltaic (PV) DC Arc-Fault Circuit Protection (Issue Number 2, January 14, 2013)