6ES7513-1AL00-0AB0

CPU 1513-1 PN, 300KB PROG., 1,5MB DATA

Mint Condition.  100% Functional. 

SIMATIC S7-1500, CPU 1513-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 300 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC MEMORY CARD NECESSARY

General information
Product type designationCPU 1513-1 PN
HW functional statusFS06
Firmware versionV1.8
Engineering with
● STEP 7 TIA Portal configurable/integrated as of versionV13 SP1 Update 4
Configuration control
via datasetYes
Display
Screen diagonal [cm]3.45 cm
Control elements
Number of keys6
Mode selector switch1
Supply voltage
Type of supply voltage24 V DC
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
● Mains/voltage failure stored energy time5 ms
Input current
Current consumption (rated value)0.7 A
Inrush current, max.1.9 A; Rated value
I²t0.02 A²·s
Power
Infeed power to the backplane bus10 W
Power consumption from the backplane bus (balanced)5.5 W
Power loss
Power loss, typ.5.7 W
Memory
SIMATIC memory card requiredYes
Work memory
● integrated (for program)300 kbyte
● integrated (for data)1.5 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
● maintenance-freeYes
CPU processing times
for bit operations, typ.40 ns
for word operations, typ.48 ns
for fixed point arithmetic, typ.64 ns
for floating point arithmetic, typ.256 ns
CPU-blocks
Number of elements (total)2 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
● Size, max.1.5 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB
FB
● Number range0 ... 65 535
● Size, max.300 kbyte
FC
● Number range0 ... 65 535
● Size, max.300 kbyte
OB
● Size, max.300 kbyte
● Number of free cycle OBs100
● Number of time alarm OBs20
● Number of delay alarm OBs20
● Number of cyclic interrupt OBs20
● Number of process alarm OBs50
● Number of DPV1 alarm OBs3
● Number of isochronous mode OBs1
● Number of technology synchronous alarm OBs2
● Number of startup OBs100
● Number of asynchronous error OBs4
● Number of synchronous error OBs2
● Number of diagnostic alarm OBs1
Nesting depth
● per priority class24
Counters, timers and their retentivity
S7 counter
● Number2 048
Retentivity
— adjustableYes
IEC counter
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 times
● Number2 048
Retentivity
— adjustableYes
IEC timer
● NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Flag
● Number, max.16 kbyte
● Number of clock memories8; 8 clock memory bits, grouped into one clock memory byte
Data blocks
● Retentivity adjustableYes
● Retentivity presetNo
Local data
● per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules2 048; max. number of modules / submodules
I/O address area
● Inputs32 kbyte; All inputs are in the process image
● Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
● Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems20
Number of DP masters
● Via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
● integrated1
● Via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
● Modules per rack, max.32; CPU + 31 modules
● Number of lines, max.1
PtP CM
● Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day
Clock
● TypeHardware clock
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
● Number16
Clock synchronization
● supportedYes
● in AS, masterYes
● in AS, slaveYes
● on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface types
● Number of ports2
● integrated switchYes
● RJ 45 (Ethernet)Yes; X1
Functionality
● PROFINET IO ControllerYes
● PROFINET IO DeviceYes
● SIMATIC communicationYes
● Open IE communicationYes
● Web serverYes
● Media redundancyYes
Interface types
RJ 45 (Ethernet)
● 100 MbpsYes
● AutonegotiationYes
● AutocrossingYes
● Industrial Ethernet status LEDYes
Protocols
Number of connections
● Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for ES/HMI/web10
● Number of connections via integrated interfaces88
● Number of S7 routing paths16
PROFINET IO Controller
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeYes
— Open IE communicationYes
— IRTYes
— MRPYes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50
— PROFIenergyYes
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.128; In total, up to 256 distributed I/O devices can be connected via PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
PROFINET IO Device
Services
— PG/OP communicationYes
— S7 routingYes
— Isochronous modeNo
— Open IE communicationYes
— IRTYes
— MRPYes
— PROFIenergyYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
SIMATIC communication
● S7 communication, as serverYes
● S7 communication, as clientYes
● User data per job, max.See online help (S7 communication, user data size)
Open IE communication
● TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
● UDPYes
— Data length, max.1 472 byte
● DHCPNo
● SNMPYes
● DCPYes
● LLDPYes
Web server
● HTTPYes; Standard and user-defined pages
● HTTPSYes; Standard and user-defined pages
Further protocols
● MODBUSYes; MODBUS TCP
Media redundancy
● Switchover time on line break, typ.200 ms
● Number of stations in the ring, max.50
Isochronous mode
Isochronous operation (application synchronized up to terminal)Yes; With minimum OB 6x cycle of 500 µs
EquidistanceYes
S7 message functions
Number of login stations for message functions, max.32
Block related messagesYes
Number of configurable alarms, max.5 000
Number of simultaneously active alarms in alarm pool
● Number of reserved user alarms300
● Number of reserved alarms for system diagnostics100
● Number of reserved alarms for Motion Control technology objects80
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 5 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Status/control
● Status/control variableYes
● VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
● Number of variables, max.
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
● Forcing, variablesPeripheral inputs/outputs
● Number of variables, max.200
Diagnostic buffer
● presentYes
● Number of entries, max.1 000
— of which powerfail-proof500
Traces
● Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LEDYes
● ERROR LEDYes
● MAINT LEDYes
● Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes
● Speed-controlled axis
— Number of speed-controlled axes, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Positioning axis
— Number of positioning axes, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● Synchronized axes (relative gear synchronization)
— Number of axes, max.3; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
● External encoders
— Number of external encoders, max.6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Controller
● PID_CompactYes; Universal PID controller with integrated optimization
● PID_3StepYes; PID controller with integrated optimization for valves
● PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
● High-speed counterYes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.0 °C
● horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
● vertical installation, min.0 °C
● vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Configuration
Programming
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— GRAPHYes
Know-how protection
● User program protection/password protectionYes
● Copy protectionYes
● Block protectionYes
Access protection
● Password for displayYes
● Protection level: Write protectionYes
● Protection level: Read/write protectionYes
● Protection level: Complete protectionYes
Cycle time monitoring
● lower limitadjustable minimum cycle time
● upper limitadjustable maximum cycle time
Dimensions
Width35 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.430 g