General information |
Product type designation | CPU 1513-1 PN |
HW functional status | FS06 |
Firmware version | V1.8 |
Engineering with |
● STEP 7 TIA Portal configurable/integrated as of version | V13 SP1 Update 4 |
Configuration control |
via dataset | Yes |
Display |
Screen diagonal [cm] | 3.45 cm |
Control elements |
Number of keys | 6 |
Mode selector switch | 1 |
Supply voltage |
Type of supply voltage | 24 V DC |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering |
● Mains/voltage failure stored energy time | 5 ms |
Input current |
Current consumption (rated value) | 0.7 A |
Inrush current, max. | 1.9 A; Rated value |
I²t | 0.02 A²·s |
Power |
Infeed power to the backplane bus | 10 W |
Power consumption from the backplane bus (balanced) | 5.5 W |
Power loss |
Power loss, typ. | 5.7 W |
Memory |
SIMATIC memory card required | Yes |
Work memory |
● integrated (for program) | 300 kbyte |
● integrated (for data) | 1.5 Mbyte |
Load memory |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup |
● maintenance-free | Yes |
CPU processing times |
for bit operations, typ. | 40 ns |
for word operations, typ. | 48 ns |
for fixed point arithmetic, typ. | 64 ns |
for floating point arithmetic, typ. | 256 ns |
CPU-blocks |
Number of elements (total) | 2 000; Blocks (OB, FB, FC, DB) and UDTs |
DB |
● Number range | 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 |
● Size, max. | 1.5 Mbyte; For non-optimized block accesses, the max. size of the DB is 64 KB |
FB |
● Number range | 0 ... 65 535 |
● Size, max. | 300 kbyte |
FC |
● Number range | 0 ... 65 535 |
● Size, max. | 300 kbyte |
OB |
● Size, max. | 300 kbyte |
● Number of free cycle OBs | 100 |
● Number of time alarm OBs | 20 |
● Number of delay alarm OBs | 20 |
● Number of cyclic interrupt OBs | 20 |
● Number of process alarm OBs | 50 |
● Number of DPV1 alarm OBs | 3 |
● Number of isochronous mode OBs | 1 |
● Number of technology synchronous alarm OBs | 2 |
● Number of startup OBs | 100 |
● Number of asynchronous error OBs | 4 |
● Number of synchronous error OBs | 2 |
● Number of diagnostic alarm OBs | 1 |
Nesting depth |
● per priority class | 24 |
Counters, timers and their retentivity |
S7 counter |
● Number | 2 048 |
Retentivity |
— adjustable | Yes |
IEC counter |
● Number | Any (only limited by the main memory) |
Retentivity |
— adjustable | Yes |
S7 times |
● Number | 2 048 |
Retentivity |
— adjustable | Yes |
IEC timer |
● Number | Any (only limited by the main memory) |
Retentivity |
— adjustable | Yes |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. | 128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB |
Flag |
● Number, max. | 16 kbyte |
● Number of clock memories | 8; 8 clock memory bits, grouped into one clock memory byte |
Data blocks |
● Retentivity adjustable | Yes |
● Retentivity preset | No |
Local data |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area |
Number of IO modules | 2 048; max. number of modules / submodules |
I/O address area |
● Inputs | 32 kbyte; All inputs are in the process image |
● Outputs | 32 kbyte; All outputs are in the process image |
per integrated IO subsystem |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
per CM/CP |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
Subprocess images |
● Number of subprocess images, max. | 32 |
Hardware configuration |
Number of distributed IO systems | 20 |
Number of DP masters |
● Via CM | 6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Number of IO Controllers |
● integrated | 1 |
● Via CM | 6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total |
Rack |
● Modules per rack, max. | 32; CPU + 31 modules |
● Number of lines, max. | 1 |
PtP CM |
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day |
Clock |
● Type | Hardware clock |
● Backup time | 6 wk; At 40 °C ambient temperature, typically |
● Deviation per day, max. | 10 s; Typ.: 2 s |
Operating hours counter |
● Number | 16 |
Clock synchronization |
● supported | Yes |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes |
Interfaces |
Number of PROFINET interfaces | 1 |
1. Interface |
Interface types |
● Number of ports | 2 |
● integrated switch | Yes |
● RJ 45 (Ethernet) | Yes; X1 |
Functionality |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes |
● Web server | Yes |
● Media redundancy | Yes |
Interface types |
RJ 45 (Ethernet) |
● 100 Mbps | Yes |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Industrial Ethernet status LED | Yes |
Protocols |
Number of connections |
● Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
● Number of connections reserved for ES/HMI/web | 10 |
● Number of connections via integrated interfaces | 88 |
● Number of S7 routing paths | 16 |
PROFINET IO Controller |
Services |
— PG/OP communication | Yes |
— S7 routing | Yes |
— Isochronous mode | Yes |
— Open IE communication | Yes |
— IRT | Yes |
— MRP | Yes; As MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50 |
— PROFIenergy | Yes |
— Prioritized startup | Yes; Max. 32 PROFINET devices |
— Number of connectable IO Devices, max. | 128; In total, up to 256 distributed I/O devices can be connected via PROFIBUS or PROFINET |
— Of which IO devices with IRT, max. | 64 |
— Number of connectable IO Devices for RT, max. | 128 |
— of which in line, max. | 128 |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
— Number of IO Devices per tool, max. | 8 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
Update time for IRT |
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive |
— for send cycle of 500 µs | 500 µs to 8 ms |
— for send cycle of 1 ms | 1 ms to 16 ms |
— for send cycle of 2 ms | 2 ms to 32 ms |
— for send cycle of 4 ms | 4 ms to 64 ms |
— With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) |
Update time for RT |
— for send cycle of 250 µs | 250 µs to 128 ms |
— for send cycle of 500 µs | 500 µs to 256 ms |
— for send cycle of 1 ms | 1 ms to 512 ms |
— for send cycle of 2 ms | 2 ms to 512 ms |
— for send cycle of 4 ms | 4 ms to 512 ms |
PROFINET IO Device |
Services |
— PG/OP communication | Yes |
— S7 routing | Yes |
— Isochronous mode | No |
— Open IE communication | Yes |
— IRT | Yes |
— MRP | Yes |
— PROFIenergy | Yes |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
SIMATIC communication |
● S7 communication, as server | Yes |
● S7 communication, as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Open IE communication |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | Yes |
— Data length, max. | 1 472 byte |
● DHCP | No |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
Web server |
● HTTP | Yes; Standard and user-defined pages |
● HTTPS | Yes; Standard and user-defined pages |
Further protocols |
● MODBUS | Yes; MODBUS TCP |
Media redundancy |
● Switchover time on line break, typ. | 200 ms |
● Number of stations in the ring, max. | 50 |
Isochronous mode |
Isochronous operation (application synchronized up to terminal) | Yes; With minimum OB 6x cycle of 500 µs |
Equidistance | Yes |
S7 message functions |
Number of login stations for message functions, max. | 32 |
Block related messages | Yes |
Number of configurable alarms, max. | 5 000 |
Number of simultaneously active alarms in alarm pool | |
● Number of reserved user alarms | 300 |
● Number of reserved alarms for system diagnostics | 100 |
● Number of reserved alarms for Motion Control technology objects | 80 |
Test commissioning functions |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | No |
Status/control |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
● Number of variables, max. | |
— of which status variables, max. | 200; per job |
— of which control variables, max. | 200; per job |
Forcing |
● Forcing, variables | Peripheral inputs/outputs |
● Number of variables, max. | 200 |
Diagnostic buffer |
● present | Yes |
● Number of entries, max. | 1 000 |
— of which powerfail-proof | 500 |
Traces |
● Number of configurable Traces | 4; Up to 512 KB of data per trace are possible |
Interrupts/diagnostics/status information |
Diagnostics indication LED |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
● Connection display LINK TX/RX | Yes |
Supported technology objects |
Motion Control | Yes |
● Speed-controlled axis | |
— Number of speed-controlled axes, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● Positioning axis | |
— Number of positioning axes, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● Synchronized axes (relative gear synchronization) | |
— Number of axes, max. | 3; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● External encoders | |
— Number of external encoders, max. | 6; Requirement: There must be no other motion technology objects created; note: The number of axes affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
Controller | |
● PID_Compact | Yes; Universal PID controller with integrated optimization |
● PID_3Step | Yes; PID controller with integrated optimization for valves |
● PID-Temp | Yes; PID controller with integrated optimization for temperature |
Counting and measuring | |
● High-speed counter | Yes |
Ambient conditions |
Ambient temperature during operation |
● horizontal installation, min. | 0 °C |
● horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
● vertical installation, min. | 0 °C |
● vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
Configuration |
Programming |
Programming language |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— GRAPH | Yes |
Know-how protection |
● User program protection/password protection | Yes |
● Copy protection | Yes |
● Block protection | Yes |
Access protection |
● Password for display | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Complete protection | Yes |
Cycle time monitoring |
● lower limit | adjustable minimum cycle time |
● upper limit | adjustable maximum cycle time |
Dimensions |
Width | 35 mm |
Height | 147 mm |
Depth | 129 mm |
Weights |
Weight, approx. | 430 g |