Introduction:

Safety saving time

The traditional method of measuring the phase sequence must be three-phase wire terminal poke , three

phase sequence tables bare alligator clips or test pin is connected to the bare3Article FireWire , rather

ETCR1000BNoncontact measurement using a clamp , do not poke the wire , without touching the bare

FireWire high pressure directly into the three super- insulated jaws were clamped inductive high

insulating sheath of the three-phase line of fire can be detected from the jacket online testing, greatly

improving safety of the field test , and effectively protect the personal safety of operating personnel ,

increase productivity !

Multiple uses

In addition to the detection of the phase sequence , as well as live -ray examination , simple seized

power, FireWire identification , phase judgment , break location to find, to detect DC line break ,

line maintenance and other functions , the equivalent of3Taiwan induction test pencil

Dynamic Display

LEDDynamic display, very intuitive !

Sensitive and reliable

ETCR1000BThe clamp is more sensitive , even to as low as a few sensorsVThe AC voltage signal ,

a wider range of electric live .

Beautiful science

ETCR1000BThe3A clamp using red, yellow and blue3Colors shell , one more in line with the

three-phase line distinction , the second overall appearance more scientific appearance.

Ultra Low Power

ETCR1000BMore power, maximum power rating only100mVA

Specifications:

Function

Inspection phase ( normal phase , reverse phase , phase ) , live -ray examination ,

simple electrical inspection , the breakpoint location, line maintenance

Power source

DC3V 2Festival5No. manganese alloy batteries(R6P) , Continuous use time is

about200Hour

Live electric range

AC0~600V,40~70Hz (Continuous sine wave input )

Can clamp the wire size

Outside diameterø10~ø40mm

LEDShow

[ Positive phase ]4A check with the lamp clockwise lights , intermittent short beeps

[ Reverse ]4A check with the lamp counterclockwise rotating lights , continuous beep

[ Live electrical voltage within the specified range ]R-S,S-TLights

[ Phase ]R-S,S-TLight does not shine

[ Interrupting ]R-S,S-TLight does not shine

Power indicator

After the boot, the boot lights

Automatic shutdown

Turn around3And a half minutes later , the meter automatically cut off power

Meter size

Width high thick70mm*75mm*0mm

Long lead clamp

0.5m

Instrument weight

About180g( With battery )

Working temperature and humidity

-10~55;80% rhThe following

Storage temperature and humidity

-20~60;90% rhThe following

Measuring the maximum voltage

AC600V

Dielectric strength

5.4kVrms

The maximum rated power

100mVA

For Safety

EN61010-1:2001,EN61010-031:2002Pollution Degree2,CAT(600V), Transient

overvoltage6000V

Random Accessories

Instrument :1Pieces ; carrying case :1Pieces