Introduction:
Safety saving time | The traditional method of measuring the phase sequence must be three-phase wire terminal poke , three phase sequence tables bare alligator clips or test pin is connected to the bare3Article FireWire , rather ETCR1000BNoncontact measurement using a clamp , do not poke the wire , without touching the bare FireWire high pressure directly into the three super- insulated jaws were clamped inductive high insulating sheath of the three-phase line of fire can be detected from the jacket online testing, greatly improving safety of the field test , and effectively protect the personal safety of operating personnel , increase productivity ! |
Multiple uses | In addition to the detection of the phase sequence , as well as live -ray examination , simple seized power, FireWire identification , phase judgment , break location to find, to detect DC line break , line maintenance and other functions , the equivalent of3Taiwan induction test pencil |
Dynamic Display | LEDDynamic display, very intuitive ! |
Sensitive and reliable | ETCR1000BThe clamp is more sensitive , even to as low as a few sensorsVThe AC voltage signal , a wider range of electric live . |
Beautiful science | ETCR1000BThe3A clamp using red, yellow and blue3Colors shell , one more in line with the three-phase line distinction , the second overall appearance more scientific appearance. |
Ultra Low Power | ETCR1000BMore power, maximum power rating only100mVA |
Specifications:
Function | Inspection phase ( normal phase , reverse phase , phase ) , live -ray examination , simple electrical inspection , the breakpoint location, line maintenance |
Power source | DC3V 2Festival5No. manganese alloy batteries(R6P) , Continuous use time is about200Hour |
Live electric range | AC0~600V,40~70Hz (Continuous sine wave input ) |
Can clamp the wire size | Outside diameterø10~ø40mm |
LEDShow | [ Positive phase ]4A check with the lamp clockwise lights , intermittent short beeps [ Reverse ]4A check with the lamp counterclockwise rotating lights , continuous beep [ Live electrical voltage within the specified range ]R-S,S-TLights [ Phase ]R-S,S-TLight does not shine [ Interrupting ]R-S,S-TLight does not shine |
Power indicator | After the boot, the boot lights |
Automatic shutdown | Turn around3And a half minutes later , the meter automatically cut off power |
Meter size | Width high thick70mm*75mm*0mm |
Long lead clamp | 0.5m |
Instrument weight | About180g( With battery ) |
Working temperature and humidity | -10~55;80% rhThe following |
Storage temperature and humidity | -20~60;90% rhThe following |
Measuring the maximum voltage | AC600V |
Dielectric strength | 5.4kVrms |
The maximum rated power | 100mVA |
For Safety | EN61010-1:2001,EN61010-031:2002Pollution Degree2,CAT(600V), Transient overvoltage6000V |
Random Accessories | Instrument :1Pieces ; carrying case :1Pieces |