DM4070 Features:
- Measures Capacitance and Inductance to 2.5%
and Resistance to 0.5%
- Simultaneous 1999 count display of the
primary parameter (L, C or R)
- Test frequencies of 1kHz
- Selectable Parallel or Series equivalent
circuit
- 3-1/2 digit backlit LCD display provides
resolution to 1pF, 1µH and 0.1ohm
- Built-in test fixture or use external test
leads
- Open and Short Zero removes unwanted stray
impedances from the measurement
- Auto power off
- Self-discharge for capacitance test
- Powered by 9V battery
- Complete with alligator clip test leads, 9V
battery, and protective holster
Basic function |
Range |
Basic
accuracy |
Capacitance |
200pF/2nF/20nF/200nF/2uF/20uF/
200uF/2000uF |
(2.5%+10) |
Inductance |
200uH/2mH/20mH/200mH/2H/20H |
(2.5%+10) |
Resistance |
20Ω/200Ω/2kΩ/20kΩ/200kΩ/20MΩ |
(0.5%+3) |
Special function |
DM4070 |
Low battery
indication |
Approx. less than
7.5V |
capacitor
discharge protect |
√ |
Auto power off |
It will power down
about 30 minutes if no any measure. |
Function protect |
√ |
Anti-shock protect |
√ |
Sampling rate |
3times/s |
Operation way |
Manual range |
Max. display |
1999 |
LCD size |
65.1mm |
Battery |
9V (6F22) not
included |
Power dissipation |
Quiescent current
approx. 6mA |
Standard accessories:
1) Test leads.
2)English manual;
Click here to download the English Manual:
http://www.ickits.com/Docs/Datasheet
/Multimeter/DM4070.doc
|