Brand New Original FLUKE 17B+ Digital MultiMeter
(with a carrying bag&batteries)
(with 14 days Hassle Free Return Policy)
General Specifications:
Maximum Voltage between any Terminal and Earth Ground: 1000 V
ACCURACY SPECIFICATION
Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy
specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Function | Range | Resolution | Accuracy | |
Model 15B+ | Model 17B+ | |||
AC Volts (40 to 500 Hz) | 400.0 mV 1 | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 | 1.0 % + 3 | |
DC Millivolts M | 400.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
DC Volts V | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 | 0.5 % + 3 |
Diode Test | 2.000 V | 0.001 V | 10 % | |
Temperature | 50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C | 0.1 °C | NA | 2 % + 1 °C ± 2 °C 9 % + 2 °C |
Resistance (Ohms) | 400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ | 0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
Capacitance 4 c | 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF 1000.0µF | 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1µF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency Hz (10 Hz -100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | NA | 0.1 % + 3 |
Duty Cycle | 0.1 % to 99.9 % | 0.1% | NA | 1% typical |
|
Function | Range | Resolution | Accuracy | ||
Model 15B+ | Model 17B+ | ||||
AC Current (40 to 200 Hz) | 400.0 µA | 0.1 µA | 1.5 % + 3 | 1.5 % + 3 | |
4000 µA | 1 µA | ||||
AC Current (40 to 200 Hz) | 40.00 mA | 0.01 mA | 1.5 % + 3 | 1.5 % + 3 | |
400.0 mA | 0.1 mA | ||||
AC Current (40 to 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 | |
DC Current | 400.0 µA | 0.1 µA | 1.5 % + 3 | 1.5 % + 3 | |
4000 µA | 1 µA | ||||
DC Current | 40.00 mA | 0.01 mA | 1.5 % + 3 | 1.5 % + 3 | |
400.0 mA | 0.1 mA | ||||
DC Current | 4.000 A | 0.001 A | 1.5 % + 3 | 1.5 % + 3 | |
10.00 A | 0.01 A | ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection |
AC Volts V | 1000 V | >10 MΩ <100 pF | >60 dB at dc, 50 or 60 Hz | _ |
DC Volts V | 1000 V | >10 MΩ <100 pF | >100 dB at dc, 50 or 60 Hz | >60 dB at 50 or 60 Hz |
STANDARD ACCESSORIES
1. A Pair of Original Test leads
2. Thermocouple3. True FLUKE F17B+ meter
4. Free black carrying bag
5. User Manual
6. Batteries
Please note: everything in the package is from original FLUKE except the carrying bag which is FREE to you.
The following FLUKE products are also available:
FLUKE 15B: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320802917216&ssPageName=STRK:MESE:IT
FLUKE 17B: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=221050433989&ssPageName=STRK:MESE:IT
FLUKE 18B: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=221130446035&ssPageName=STRK:MESE:IT
FLUKE
FLUKE 62: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=321006211057&ssPageName=STRK:MESE:IT
FLUKE
T5-1000: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320990348519&ssPageName=STRK:MESE:IT
FLUKE 302+ Digital Clamp Meter: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320916167361&ssPageName=STRK:MESE:IT
FLUKE 362 Digital Clamp Meter: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320990975551&ssPageName=STRK:MESE:IT
FLUKE 365 Digital Clamp Meter: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320990347700&ssPageName=STRK:MESE:IT
FLUKE 317 Digital Clamp Meter: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320967981179&ssPageName=STRK:MESE:IT
FLUKE 319 Digital Clamp Meter: http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=320804539630&ssPageName=STRK:MESE:IT
This multimeter can be used for measure the temperature and output voltage of this TEC controllers:
http://www.analogti.com/thermo-system-components/high-efficiency-tec-controllers.html
This multimeter can be used for measure the inductance of these inductors:
http://www.analogti.com/electronic-components/smt-inductor-kits.html
This multimeter can be used to measure the resistor of this thermistor:
http://www.analogti.com/thermo-system-components/high-stability-thermistors.html