Mini Ductless Split Air Conditioner 39000 BTU
Thermospace Mini Split

Thermospace Contact

48000 BTU INVERTER Quad Zone Mini Split AC
19.5 SEER Efficiency w/ Heat Pump
With a 48000 BTU total Cool / Heat Capacity, the Thermocore T119D-H236-12+12+12+12 ENERGY STAR mini split air conditioner can cool or heat 4 separate zones of 12000, 12000, 12000, & 12000 BTU for a total coverage area of 2400 ft² (600 ft² x 4).  A 19.5 SEER coupled with Inverter technology provides benefits of low operation temps, rapid cooling / heating as well as maximum energy efficiency. Install Kits Sold Seperately.
 
arrowFeatures
arrowSpecifications
arrowInverter Technology
arrowControls
arrowSetup - Installation
arrowWarranty
arrowShipping
arrowAvailable Accessories

39000 BTU Mini Split

system

Indoor Unit Indoor Unit Outdoor Unit Installation Kit

Technical Data: System Includes:
  • 48,000 BTU INVERTER Cooling Capacity: (12k + 12k + 12k + 12k)
  • 48,000 BTU INVERTER Heat Capacity: (12k + 12k + 12k + 12k)
  • 19.5 SEER - 9.0 HSPF - AHRI/Energy Star Certified
  • Pre-Charged with ECO-Friendly R410A
  • 1 Year Parts - 5 Year Compressor Warranty  View Details >
  • Indoor Unit - Air Handler.
  • Outdoor Unit - Condenser of 36,000 BTUs
  • Digital Multi-function LCD Remote Control.
  • Product and Installation Manual. >>>
* When all air handlers are running simultaneously at full capacity, the total combined BTU output is limited to that of the outdoor condenser.

Features back to  the top
Inverter  Split
Top Line Features:
  • 19.5 SEER - 9.0 HSPF - ENERGY STAR  Energy Star
  • Dry-Mode removes moisture w/o affecting temperature
  • Cross Flow Technology reduces Noise Output
  • Compatible with over 5 Filtration Medias
  • Freon Leak Detection > Notification System
  • Low Ambient Temperature Operation (5° F)
  • Two-direction Air vane Evenly Distributes Air
  • Restart IC: Settings restored Following Power Outage
  • Follow-Me Function tracks Remote Location
** Installation Lineset Sold Seperately: Available in 15-75ft Lengths.
Contact us
for customized package or Click here to Purchase.
 
Energy Star benefits


feature
 
The particle filter or “pre-filter” removes dust and other air-borne pathogens before pushing the air through additional filtration medias and the refrigeration coil array.  This filter is washable and comes factory installed with every ductless air conditioner system.
 
 
The open channel construction of the 3M High Air Flow (HAF) filter offers low initial airflow resistance, while its unique microstructure and electrostatic charge provides effective particle capture and retention. This translates into fewer filter change outs and reduced coil cleaning.  
CLICK TO PURCHASE >>>
 
The Vitamin C Filtration media releases Vitamin C into the air which softens skin and reduces stress among other therapeutic benefits.  A good choice for those wanting to add some invigoration to their indoor air environment.  Filter lasts over 2 years.  CLICK TO PURCHASE >>>
 
The anti-microbial effect of silver ionic technology kills allergy causing bacteria by destroying the inner configuration elements of the cell body. The nano-silver attached to the filter screen constantly releases silver ions which directly eliminates and prohibits bacteria from replicating.  
CLICK TO PURCHASE >>>
 
Eliminates odors such as ammonia and deactivates harmful chemicals has such as formaldehyde.  By forming positive positions on the filter surface, Electrostatic Fiber traps small dust particles, smoke and pet dander to prevent allergic reactions and neutralize odor in the air.  
CLICK TO PURCHASE >>>

Specifications back to  the top
Indoor Unit (evaporator) specs CLICK FOR FULL SPEC SHEET
Model Number T1-OS212-EW
Capacity 12000 BTU
Air Flow (Hi/M/Lo) 440/380/260 cfm
Power Supply 230 V / 60 Hz / 1Ph
Noise Output (Hi/M/Lo) 43/37/31 dBA
Liquid / Gas 1/4" x 3/8"
Weight 18.7 lbs
Dimensions (W x D x H) 32.9" × 7.8" × 11" in.
VIEW FULL AIR HANDLER SPECIFICATION SHEET >>>
 
Energy Star Cooling & Heating Energy Star
Toshiba Compressor 21 SEER
Outdoor Unit (condenser) specs CLICK FOR FULL SPEC SHEET
Model Number T119D-H236
Compressor Brand MITSUBISHI
Rated Capacity 36000 BTU
Maximum AH Capacity 54000 BTU
Air Flow 2240 CFM
Power Supply 230 V / 60 Hz / 1Ph
Input Power 1300W - 4200W
SEER 19.5
EER 10
HSPF4 9.0
Sound Level 65 dBA
Moisture Removal
2.6 L/hr
Operating Temp Range 5 - 122 F (cool and heat)
Refrigerant R410A / 95oz Charge
Liquid / Gas 1/4" x 3/8" (4)
Max Lineset Length (1 zone) 98 ft
Max Lineset Length (all zones) 197 ft
Weight 179.7 lbs
Dimensions (W x D x H) 39 × 13.5 × 38 inches
VIEW FULL CONDENSER SPECIFICATION SHEET >>>
CLICK TO VIEW COMBINATION CALCULATION TABLE >>>

Remote  Controls back to  the top

inside  
WHAT IS DC INVERTER?

DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field.  They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor.  YMGI Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current.  DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power.  Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.

Conventional compressors turn on and off to maintain the room temperature at desired level.  This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off.  Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature.  The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly. Once the set temperature is reached, it slows down and adjust its capacity to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.



DC Inverter Energy Efficient Heating & Cooling Mini  Splits

Inverter Split

INVERTER
 
Install Kit back to  the top
 
Installation Overview back to  the top

BASIC OVERVIEW: Click for Installation Manual. The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables (NOT INCLUDED).  Click for supplies page. The condensing unit comes pre-charged with R410A refrigerant however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below > Ductless Split Air Conditioner  Installer

Installation Diagram

Multi Zone Pics

Remote  Controls back to  the top
*5 Year Compressor - 1 Year on all other Parts*  Registration card will be sent with unit, this card should be completed by an HVAC technician (installer).  Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship.  Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge.   The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed.  Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty).  If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost.  Damaged / Defective product will be picked up and brand new exchange will be shipped out.

Available  Accessories back to  the top
US   SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS!   Canadian
Our Thermocore systems ship via RL Carriers or similar LTL freight service out of Oak Park, Michigan and are palletized onto a single skid.  Transit time is usually between 4 to 6 business days from payment receipt depending on where you are geographically located.  Please provide a contact phone# upon checkout (to be used for delivery purposes only).  SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order.  Failure to provide valid contact# will delay order.  System comes with Free shipping - this includes delivery to any location within the Continental United States. We will ship to Canadian locations but we need to quote separately - please contact our offices.  Additional freight for Canadian registries is usually around $150. (import and duties may apply).
  RL  Carriers

Available Accessories back to  the top
Condenser Ground Stand
Stand

- Provides Flat even surface
- Avoids debris obstruction

Price:  $73.00
Click for more Info

Lineset (1/4 x 3/8)
Lineset

- Required for Installation
25ft - 30ft - 40ft - 50ft
Lengths
Price:  $38.00 > $134.00
Click for more Info

Condenser Bracket
Bracket

- Mount your condenser at any height on an outdoor sidewall
Price:  $46.00
Click for more Info

Micro-Pump II
Lineset

- Required when mounting air handler on Interior wall
Price:  $132.00
Click for more Info

Electrical Wire Harness
Wire

- 16/4 Electrical Wire Harness
- For Extending Evap. Length

Price:  $2.15 / ft
Click for more Info

Additional Remote Controls
Remotes

- Spare remote controls for the T1 Series Ductless System
Price:  $42.00
Click for more Info

Filter Medias
Filters

- Inserts into Filter Screen Slot
- Choice of 4 Filtration Medias

Price:  $10.00 - $14.00
Click for more Info

Wired Thermostat
Wired Thermostat

- Permanently Hard Mounts
- Controls Settings w/ Remote

Price:  $98.00
Click for more Info

 
Available Accessories back to  the top
Options
Swap 1- 12k Mount for Cassette: (+) $120
Swap 2- 12k Mount for Cassette: (+) $240
Swap 4- 12k Mount for Cassette: (+) $360
Swap 4- 12k Mount for Cassette: (+) $480
Swap 1-12k Mount for Suspended Ceiling: (+) $250
Swap 2-12k Mount for Suspended Ceiling: (+) $500
Swap 3-12k Mount for Suspended Ceiling: (+) $750
Swap 4-12k Mount for Suspended Ceiling: (+) $1000
This  unit
*If alternate air handler types are preferred, contact us and request invoice with preferred options. Availability fluctuates.
 
Customize your system to meet your requirements - see below table for available output options:
Tri-Zone Setup
9k + 18k + 18k 12k + 12k + 18k
12k + 18k + 18k 18k + 18k + 18k
Quad-Zone Setup
9k + 9k + 9k + 9k 9k + 9k + 9k + 12k 9k + 9k + 12k + 12k
9k + 12k + 12k + 12k 9k + 9k + 9k + 18k 9k + 9k + 12k + 18k
9k + 12k + 12k + 18k 12k + 12k + 12k + 12k 12k + 12k + 12k + 18k
This system available in multiple air handler (zone) capacity combinations to meet the requirements of any application.  Air handlers are available in 9k, 12k and 18k outputs. Be advised, for arrangements where combined output of all heads exceeds rated capacity of condenser (36000 BTU's) - the total output will not exceed 36000's when all air handlers are running at full capacity simultaneously.  However, overated zones will draw required capacity from other zones either running at lower modes or areas that have reached thermostat settings to obtain rated output.  For example, with a 12k-12k-12k-12k configuration, the total output will be along the lines of 10k-10k-10k-10k when all zones are running on high/full settings at the same time.  However, once a zone obtains set temperature and/or operates at a lower setting, the capacity will bleed off into zone that needs the extra push to obtain the 12k-12k-12k-12k yield.
Line


Dual Zone Senville Mini Split, 24000 BTU AC Air Conditioner w/ Heat  Pump


View the Mini Split FAQ > View the Mini Split Outline Diagram > Click to contact us >