Tektronix AFG320
Manufacturer: Tektronix |
Model: AFG320 |
|
Description: Arbitrary Function Generators |
Tektronix AFG320 Specifications: - 2 Channels
- Standard Waveforms - Sine, Square, Triangle, Ramp, Pulse, DC and Noise.
User Waveforms - (Preprogrammed samples)- USR1: Sin (X)/X
- USR2: Double Exponential Pulse
- USR3: Damped Sine Wave
- USR4: NRZ Random Signal
Arbitrary Waveforms- Waveform Length: 10 to 16384 points.
- Vertical Resolution: 12-Bit.
- Sample Rate: 16 MS/s.
- Nonvolatile Memory: Four 16 k waveforms.
Output Frequency- Sine, Square: 0.01 Hz to 16 MHz.
- Triangle, Ramp, Pulse: 0.01 Hz to 100 kHz.
- Noise (Gaussian): Maximum 8 MHz bandwidth.
- Arbitrary Waveform:
- Repetition Rate: 0.01 Hz to 1.6 MHz.
- Resolution: 7 digits.
- Accuracy: 50 ppm.
Output Characteristics- Amplitude (into 50 Ω): 50 mVp-p to 10 Vp-p.
- Accuracy: ±(1% of setting + 5 mV) at 1 kHz, no offset.
- Flatness (at 1 V amplitude relative to 1 kHz):
- <100 kHz: ±1%.
- 100 kHz to 1 MHz: ±1.5%.
- 1 MHz to 16 MHz: ±3%.
- Offset (into 50 Ω):
- 505 mVp-p to 10 Vp-p amplitude: peak amplitude + offset is limited to +5 V or -5 V.
- 50 mVp-p to 500 mVp-p amplitude: -0.75 V to +0.75 V.
- Accuracy: ±(1% of setting +5 mV).
- Resolution: 5 mV.
- Output Impedance: 50 Ω.
- Isolation: 42 V peak maximum relative to earth ground.
- Phase:
- Range: ±360°.
- Resolution: 1°.
Sine Wave Spectral Purity- Harmonic Distortion:
- DC to 20 kHz: -65 dBc.
- 20 kHz to 100 kHz: -60 dBc.
- 100 kHz to 1 MHz: -45 dBc.
- 1 MHz to 16 MHz: -35 dBc.
- Total Harmonic Distortion:
- 20 kHz: 0.05% at 1 V amplitude.
Signal Characteristics- Square:
- Rise/Fall Time: ≤20 ns.
- Overshoot: <<2%.
- Pulse:
- Rise/Fall Time: <<100 ns.
- Duty Cycle: 1% to 99% of period.
- Triangle, Ramp, Pulse, Arbitrary:
- Jitter: 2 ns at 100 kHz.
Modulation- AM:
- Source: External only.
- Carrier: Up to 16 MHz.
- Modulation: Any internal waveform plus Arb.
- Frequency: DC to 200 kHz.
- Depth:
- 1 V: 100%.
- 0 V: 50%.
- -1 V: 0%.
- 2 Vp-p for 100% modulation.
- FM:
- Source: Internal only.
- Modulation: Sine, Square, Triangle, Arb.
- Frequency: 0.01 Hz to 10 kHz.
- Deviation: 0.01 Hz to 8 MHz.
- FSK (frequency shift keying):
- Source: Internal only.
- Mode: Trigger, Burst.
- Frequency range: 0.01 Hz to 16 MHz.
- Key rate: 0.01 Hz to 50 kHz.
- Number of keys: 2.
Frequency Sweep- Type: Linear or logarithmic.
- Direction: Up or down.
- Start/Stop Frequency: 0.01 Hz to 16 MHz.
- Time: 1 ms to 100 s.
- Mode: Continuous, Trigger, Burst.
Operating Mode- Continuous: The selected waveform is output continuously.
- Triggered: One period of the selected waveform is output each time a trigger occurs.
- Trigger source: Manual, external.
- Burst: The selected waveform is output with a specified number of cycles each time a trigger occurs.
- Carrier Frequency: Up to 1 MHz.
- Count: 1 to 60,000 cycles/burst (100 s maximum except sine wave or square wave) or infinite.
- Start phase: -360 to +360°.
- Trigger source: Manual, external.
Inputs/Outputs- Front panel:
- Main output: 2 Channels
- External Trigger (Burst) input:
- TTL input.
- Pulse-width: 1 μs minimum.
- 10 kΩ input impedance.
- Rear panel:
- Sync output: TTL level.
- External AM modulation:
- 2 Vp-p = 100% modulation.
- 10 kΩ input impedance.
- GPIB Interface (IEEE-488.2).
Memory- Type: Non-volatile.
- Setup Storage: 20.
- Arbitrary Waveform Storage: 4.
- Environmental, EMC, Safety
Temperature Range- Operating: 0 °C to +50 °C.
- Nonoperating: -20 °C to +60 °C.
Humidity- Operating:
- At or below +40 °C: 0 to 95%.
- +40 °C to +50 °C: 0 to 75%.
Random Vibration- Operating: 0.31 GRMS from 5 to 500 Hz, 10 minutes.
- Nonoperating: 2.46 GRMS from 5 to 500 Hz, 10 minutes.
- Shock - Nonoperating: 294 m/s2 (30 G), half-sine, 11 ms duration.
|
Working Instrument. Lab tested to be fully operational. |
|
Accessories:
- Manual Set (CD) Qty. 1
- Power Cord Qty. 1
Note: The unit has no handle or feet. |
|
Shipping Weight: 25.00 lbs (11.34 kgs) |
|
Terms and conditions:
- All units power on without error.
- 30 Days Warranty against parts and labor defects (Spectra Test Equipment will attempt to fix or replace the defective unit. Otherwise money back refund minus shipping cost)
- Unit must be received by Spectra Test Equipment in the same condition as that was received by the buyer (includes warranty stickers remain intact).
- All units are supplied exactly as shown.
- All equipment is packed with Instapack® foam-in-place.
- Buyer is responsible for all applicable sales tax, shipping (includes returns), and handling costs.
- Shipment by UPS or FedEx
- Domestic handling is a flat fee of $20.00 US plus actual shipping.
- International handling is a flat fee of $25.00 US plus actual shipping.
- If you would like, we are more than happy to ship freight collect to your UPS/DHL/FedEx account (plus handling).
- Insurance is required for all shipments.
- We accept the following methods of payment:
- Bank Transfer is required for all international orders (carries a $25.00 fee).
- PayPal
- Certified Check, Personal Check (allow 10 days after receipt for personal checks to clear).
| |
| |