FAST and SAFE shipping from California, USA, w/tracking #.
Order status and shipping info (shipping time, the tracking # & website) will be proviede by us thru. ebay email after the payment is received. If you don't receive these 2 e-mails, check your spam folder of your e-mail account. |
Brand New FLUKE 17B+ Digital MultiMeter (with free carrying bag) You can also download English user manual online: http://assets. fluke. com/manuals/151718__umeng0000.pdf |
New Feature:
General Specifications:
AC and DC Voltage
Function | Range | Resolution | Accuracy | ||
15B+ | 17B+ | 18B+ | |||
AC Volts (40Hz-500Hz)[1] | 4.000V 40.00V 400.0V 1000V | 0.001V 0.01V 0.1V 1V | 1.0 % + 3 | 1.0 % + 3 | 1.0 % + 3 |
AC Millivolts | 400.0mV | 0.1mV | 3.0 % + 3 | 3.0 % + 3 | 3.0 % + 3 |
DC Millivolts | 400.0mV | 0.1mV | 1.0 % + 10 | 1.0 % + 10 | 1.0 % + 10 |
DC volts | 4.000V 40.00V 400.0V 1000V | 0.001V 0.01V 0.1V 1V | 0.5 % + 3 | 0.5 % + 3 | 0.5 % + 3 |
[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. |
AC and DC current
Function | Range | Resolution | Accuracy | ||
15B+ | 17B+ | 18B+ | |||
AC Current μA (40 Hz-400Hz) | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
AC current Ma (40Hz – 400Hz) | 40.00 m 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
AC current A[1] (40Hz – 400Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
DC current μA | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
DC current A[1] | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 | 1.5 % + 3 |
[1] 10 A duty cycle < minutes on, 20 minutes off. |
Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle
Range | Resolution | Accuracy | |||
15B+ | 17B+ | 18B+ | |||
Diode Test[1] | 2.000V | 0.001V | 10 % | ||
Temperature | 50.0°C-400.0°C 0°C-50.0°C -55.0°C -0°C | 0.1°C | NA | 2 % +1°C 2°C 9% +2°C | NA |
Resistance (Ohms) | 400.0Ω 4.000KΩ 40.00KΩ 400.0KΩ 4.000MΩ 40.00MΩ | 0.1Ω 0.001KΩ 0.01KΩ 0.1KΩ 0.001MΩ 0.01MΩ | 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 | 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 | 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 |
Capacitance[2] | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001μF 0.01μF 0.1μF 1μF | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 | 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
Frequency[3] (10Hz -100kHz) Hz | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | NA | 0.1%+3 | 0.1%+3 |
Duty Cycle[2] | 1% to 99% | 0.1 % | NA | 1%typical[4] | 1% typical[4] |
[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA [2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range). [3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified. [4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %. |
LED Test and Continuity Threshold
Function | Lighting Range | Measurement Range | Resolution | Accuracy |
LED VF Test[1] (LED Test Socket) | 1.00 to 6.00 V | NA | NA | NA |
LED VF Test[2] ( Test leads) | 1.00 to 6.00V | 1.00 to 6.00V | 0.01V | 10%[3] |
Continuity Threshold | NA | NA | NA | NA |
[1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical) [2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical) [3] VF Measurement with driving current under2.2±0.4 mA |
Input Characteristics
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 1000V[1] | >10MΩ,<pF | >60 dB at dc, 50Hz or 60Hz | _ |
AC Millivolts | 400mV | >1MΩ,<100pF | >80dB at dc, 50Hz or 60 Hz | _ |
DC Volts | 1000V[1] | >10MΩ,<100pF | >100dB at dc, 50Hz or 60 Hz | >60dB at 50Hz or 60 Hz |
DC Millivolts | 400mV | >1MΩ,<100pF | >80dB at ac, 50 Hz or Hz | _ |
[1]106V Hz Max |
(please note: everything in this package is from original FLUKE except the carrying bag which is FREE to you):
1. A Pair of Original Test leads
2. F17B+ meter
3. FREE black carrying bag!
4. User manual.
5. Batteries.