Official PayPal Seal

FAST and SAFE shipping from California, USA, w/tracking #.

Order status and shipping info (shipping time, the tracking # & website) will be proviede by us thru. ebay email after the payment is received. 

If you don't receive these 2 e-mails, check your spam folder of your e-mail account.

Brand New FLUKE 17B+ Digital MultiMeter

(with free carrying bag)

Please note:

1.This multimeter includes batteries. However, due to Customs regulations, a plastic film is wrapped outside the batteries in the battery jar. Please remove the plastic film before using.

2.This meter is made by FLUKE manufacturer in China. Now China Fluke manufactures don't provide printed English user manual. The meter comes with an English user manual printed by us.

You can also download English user manual online: http://assets. fluke. com/manuals/151718__umeng0000.pdf

 

 

New Feature:

  • Faster response
  • Greater capacitance range: 0.01nF ~ 1000μF
  • The more bright: Add white LED backlight
  • Larger screen: Larger than the original 1.5 times  

    General Specifications: 

    Maximum Voltage between any Terminal and Earth Ground: 1000 V
    Display(LCD)..................................................4000 counts,updates 3/sec
    Battery Type...................................................2 AA,NEDA 15A, IEC LR6
    Battery life.......................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)
     
    Temperatuer
    Operating.........................................................0 deg to 40 deg
    Storage.............................................................-30 deg to 60 deg
    Relative Humidity
    Operating Humidity.......................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
    Operating Humidity,40MC Range..............≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
    Altitude
    Operating.........................................................2000m
    Storage.............................................................12.000m
    Temperature Coefficient..............................0.1×(specified accuracy)/deg(<18deg or > 28deg)
    Fuse protection for current inputs............440 mA,1000 V Fast Fuse, Fluck specified part only.
                                                                                11A,1000v Fast Fuse, Fluke specified part only.
    Size(H×W×L)...................................................183×91×49.5(mm)
    Weight..............................................................455g
    IP Rating..........................................................IP 40
    Safety...............................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2
    Electromagnetic Environment...................IEC 61326-1:Portable
    Electromagnetic Compatibility..................Applies to use in Korea only
                                                                               Class A Equipment(Industrial Broadcasting and Communication Equipment)

    AC and DC Voltage

    Function

    Range

    Resolution

    Accuracy

    15B+

    17B+

    18B+

    AC Volts

    (40Hz-500Hz)[1]

     

    4.000V

    40.00V

    400.0V

    1000V

    0.001V

    0.01V

    0.1V

    1V

    1.0 % + 3

    1.0 % + 3

    1.0 % + 3

    AC Millivolts

    400.0mV

    0.1mV

    3.0 % + 3

    3.0 % + 3

    3.0 % + 3

    DC Millivolts

    400.0mV

    0.1mV

    1.0 % + 10

    1.0 % + 10

    1.0 % + 10

    DC volts

    4.000V

    40.00V

    400.0V

    1000V

    0.001V

    0.01V

    0.1V

    1V

    0.5 % + 3

    0.5 % + 3

    0.5 % + 3

    [1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.


    AC and DC current

    Function

    Range

    Resolution

    Accuracy

    15B+

    17B+

    18B+

    AC Current μA

    (40 Hz-400Hz)

    400.0 μA

    4000 μA

    0.1 μA

    1 μA

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    AC current Ma

    (40Hz – 400Hz)

    40.00 m

    400.0 mA

    0.01 mA

    0.1 mA

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    AC current A[1]

    (40Hz – 400Hz)

    4.000 A

    10.00 A

    0.001 A

    0.01 A

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    DC current μA

    400.0 μA

    4000 μA

    0.1 μA

    1 μA

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    DC current mA

    40.00 mA

    400.0 mA

    0.01 mA

    0.1 mA

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    DC current A[1]

    4.000 A

    10.00 A

    0.001 A

    0.01 A

    1.5 % + 3

    1.5 % + 3

    1.5 % + 3

    [1]   10 A duty cycle < minutes on, 20 minutes off.



    Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle

    Function

    Range

    Resolution

    Accuracy

    15B+

    17B+

    18B+

    Diode Test[1]

    2.000V

        0.001V

    10 %

    Temperature

     

    50.0°C-400.0°C

    C-50.0°C

    -55.0°C -0°C

        0.1°C

     

    NA

    2 % +1°C

    C

    9% +2°C

    NA

    Resistance

    (Ohms)

    400.0Ω

    4.000KΩ

    40.00KΩ

    400.0KΩ

    4.000MΩ

    40.00MΩ

    0.1Ω

    0.001KΩ

    0.01KΩ

    0.1KΩ

    0.001MΩ

    0.01MΩ

    0.5%+3

    0.5%+2

    0.5%+2

    0.5%+2

    0.5%+2

    1.5%+3

    0.5%+3

    0.5%+2

    0.5%+2

    0.5%+2

    0.5%+2

    1.5%+3

    0.5%+3

    0.5%+2

    0.5%+2

    0.5%+2

    0.5%+2

    1.5%+3

    Capacitance[2]

    40.00 nF

    400.0 nF

    4.000 μF

    40.00 μF

    400.0 μF

    1000 μF

    0.01 nF

    0.1 nF

    0.001μF

    0.01μF

    0.1μF

    1μF

    2% + 5

    2% + 5

    5% + 5

    5% + 5

    5% + 5

    5% + 5

    2% + 5

    2% + 5

    5% + 5

    5% + 5

    5% + 5

    5% + 5

    2% + 5

    2% + 5

    5% + 5

    5% + 5

    5% + 5

    5% + 5

    Frequency[3]

    (10Hz -100kHz)

    Hz

    50.00 Hz

    500.0 Hz

    5.000 kHz

    50.00 kHz

    100.0 kHz

    0.01 Hz

    0.1 Hz

    0.001 kHz

    0.01 kHz

    0.1 kHz

    NA

    0.1%+3

    0.1%+3

    Duty Cycle[2]

    1% to 99%

    0.1 %

    NA

    1%typical[4]

    1% typical[4]

    [1]  Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA

    [2]  Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).

    [3]  All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.

    [4]  Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.


    LED Test and Continuity Threshold

    Function

    Lighting Range

    Measurement Range

    Resolution

    Accuracy

    LED VTest[1]

    (LED Test Socket)

    1.00 to 6.00 V

    NA

              NA

    NA

    LED VTest[2]

    Test leads)

    1.00 to 6.00V

    1.00 to 6.00V

    0.01V

    10%[3]

    Continuity Threshold

    NA

                NA

    NA

    NA

    [1]  Open circuit test voltage is±12V and short-circuit current is<±5mA(typical)

    [2]  Open circuit test voltage is±12V and short-circuit current is<±3mA(typical)

    [3]  VF Measurement with driving current under2.2±0.4 mA

     

    Input Characteristics

    Function

    Overload Protection

    Input Impedance

    (Nominal)

    Common Mode

    Rejection Ratio

    Normal Mode

    Rejection Ratio

    AC Volts

    1000V[1]

    >10MΩ,<pF

    >60 dB at dc,

    50Hz or 60Hz

    _

    AC Millivolts

    400mV

    >1MΩ,<100pF

    >80dB at dc,

    50Hz or 60 Hz

    _

    DC Volts

    1000V[1]

    >10MΩ,<100pF

    >100dB at dc,

    50Hz or 60 Hz

    >60dB at

    50Hz or 60 Hz

    DC Millivolts

    400mV

    >1MΩ,<100pF

    >80dB at ac,

    50 Hz or Hz

    _

    [1]106V Hz Max


  • This meter is made by FLUKE manufacturer in China. Now China Fluke manufacturers don't provide printed English user manual. The meter comes with an English user manual printed by us. 
    You can also download English user manual online: http://assets.fluke.com/manuals/151718__umeng0000.pdf
     
    Standard Accessories

    (please note: everything in this package is from original FLUKE except the carrying bag which is FREE to you):

    1. A Pair of Original Test leads

    2. F17B+ meter

    3. FREE black carrying bag!

    4. User manual.

    5. Batteries.

    TERMS & CONDITIONS

    Please read carefully before purchase. Thank you!

    I. PAYMENT

    Credit or debit card through PayPal     

    We accept payments by PayPal or Visa, MasterCard, Discover and American Express by phone at 1-408-748-9100 during business hours.


    II. SHIPPING

    1. We use USPS, UPS or FedEx depending on the item.

    2. All orders placed on Friday after 3pm, Saturday and Sunday will be shipped on following Monday.  If Monday is a national holiday, the orders will be shipped on Tuesday. Local pick up is available – Santa Jose, CA. You can pay cash or credit card at our office. We’ll notify you the order status and shipping info, the time shipped, the tracking number and the tracking website once it’s been shipped. If you don’t receive the email from us (thru eBay), please check your spam folder. Please contact your local post office for missing or damaged package.  

     

    III. RETURN/EXCHANGE  

    1. We offer 30 day 100% refund and split the shipping cost with you: we pay out bound shipping and you pay return shipping. But please CONTACT us before shipping back any items. When we get the item back, we will grant you a full refund or replacements as per your request.

    2. We store and ship out items from our Silicon Valley, California, office. To return items, you ship them to our California office, not a place in China as many other sellers will force you to do, which will cost you more to ship than the refund fee.

    3. The item shall be returned in its original condition (packaging and accessories) in order to get it refunded or replaced; Moreover, please put a paper in the package, on which write down your user name, purchase date and the order number. 

     

    IV. FEEDBACK

     

    We are committed to your 100% satisfaction. Please CONTACT us if there are any questions or concerns about your purchase. We will do our best to help you within the shortest time. As long as you are happy with your purchase, please don't forget to leave us a positive feedback, we will really appreciate it and do the same for you!


     

    V. CUSTOMER SERVICE

    Tel.: 408-748-9100

    Fax: 408-748-9111

    Office location: 1161 Ringwood Court, #110 San Jose, CA 95131 U.S.A.

    Office hours: M-F, 9am to 5pm (Pacific Time)

    We have full time staff answering phone calls alive for tech and sales support from 8am to 5pm Pacific time, and reply emails instantly.

    We have made tens of thousands customers happy world wide, otherwise, we would have not been in business for 20 years.


    This multimeter works perfect with this resistor kit

    http://www.analogtechnologies.com/resistorkits.htm

    This multimeter can be used for measuring these capacitors: 

    http://www.analogtechnologies.com/capacitorkits.htm

    This multimeter can be used for measuring the input and output currents of this laser drivers:

    http://www.analogtechnologies.com/laserdriver.html