EasyTouch ET-201 Multi-function Blood Glucose and Uric Acid Meter Test Kit
ET-201 EasyTouch Blood Glucose and Uric Acid Meter is a multi-function blood glucose meter system that measures blood glucose and uric acid together. Also it is very compact in size with one-button feature,which makes it simple to use without sacrificing the quality and accuracy.
Specifications
- Test Functions: Blood Glucose and Uric Acid Test system
- Glucose Measuring Range: 20 – 600 mg/dL(1.1 – 33.3 mmol/L)
- Uric Acid Measuring Range: 3 – 20 mg/dL(179 – 1190 μmmol/L)
- Memory: 200 memories for Glucose, 100 memories for Uric Acid
- Test Time: 10 seconds for Glucose, 20 seconds for Uric Acid
- Operation Temperature: 14 – 40 ℃ (57.4 - 104℉)
- Operation Humidity: ≧ 85%
- Storage Temperature: -10 – 60 ℃ (14 - 140℉)
- Storage Humidity: ≧ 95%
- Sample Volume: ≧4μl for Glucose and Uric Acid
- Sample Type: Capillary whole blood
- Hematocrit Rage: 30 – 55%
- Power Supply: 1.5V (AAA) x 2
- Battery Life: Approximately 1000 tests
- Display: LCD display (35 x 45mm)
- Dimension: 88 (H) x 64 (W) x 22 (D)mm
- Weight: 59 g (without battery)
- Technology Used: Electrode-based amperornetric and Amperornetric Enzyme Electrode
- Time & Date Display
- Glucose Average Result: 7 / 14 / 28 days
- Power On & Off: Automatically
- Strip Type: Siphonal Strip (Capillary Action)
- Warranty : 2 Year.
- Made in Taiwan Excellent quality.
Contents of ET-201
- Dual-Function Meter
- Lancing Device
- 10 Lancets
- 1 Check Strip
- 2 AAA Batteries
- 1 Carrying Case
- User's Manual
- 1 Log Book
- 1 Simple Operating Insert
- 1 Warranty Card
- 10 Blood Glucose Strips
- 10 Uric Acid Strips
- Made in Taiwan excellent quality.
To purchase extra Strips please click on the following E-BAY link.
Disclaimer:
- The self-testing EasyTouch GU Blood Glucose/Uric Acid Multifunction Monitoring System is designed for in vitro diagnostic use only(external use only).
- Do not change your medical plan without doctors approval.
- The EasyTouch GU system should not be used for the diagnosis of diabetes and hyperuricemia or for the newborns.
- Blood specimens containing ascorbic acid(Viamin C) greater than 150mg/dL,Amiloride greater than 20 mg/dL,acetaminophen greater than 8mg/dL,L-Dope greater than 20mg/dl,Dopamine greater than 20 mg/dL,Methyl-Dope greater than 4 mg/dL,Galactose greater than 400 mg/dL,uric acid greater than 10.5 mg/dL and Xylose greater than 50mg/dL may give inaccurate glucose results.
- Blood specimens containing ascorbic acid (Viamin C) greater than 10 mg/dL,acertaminophen greater than 2 mg/dL,L-Dopa greater than 20 mg/dL,Dopamine greater than 5 mg/dL,Methyl-Dopa greater than 0.3 mg/dL,Glibenclimide greater than 10 mg/dL,creatine greater than 30 mg/dL,Bilirubin greater than 40 mg/dL and ketoprofen greater than 300 mg/dL may give inaccurate uric acid results.