MODEL | AS-120-5 | AS-120-12 | AS-120-15 | AS-120-36 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 36V |
RATED CURRENT | 0~24A | 0~10A | 0~8A | 0~3.3A | |
RATED POWER | 120W | 120W | 120W | 120W | |
RIPPLE&NOISE | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
VOLTAGE ADJ.RANGE | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 32.4-39.6V | |
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP,RISE TIME | 500ms,20ms/230VAC | ||||
HOLD UP TIME(TYP.) | 30ms/230VAC 25ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 170-264VAC 240-370VDC | |||
FREQUENCY RANGE | 47-63HZ | ||||
EFFICIENCY(Typ.) | 80% | 83% | 84% | 86% | |
AC CURRENT(Typ.) | 2.4A/115V 1.2A/230VAC | ||||
INRUSH CURRENT | COLD START 30A/115V 60A/230V | ||||
LEAKAGE CURRENT | 1mA/240VAC | ||||
PROTECTION | OVERLOAD | 105-150% RATED OUTPUT POWER | |||
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
OVER VOLTAGE | 115-135% RATED OUTPUT VOLTAGE | ||||
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
ENVIRONMENT | WORKING TEMP | -10~+60°C | |||
WORKING HUMIDITY | 20-90%RH non-condesing | ||||
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | ||||
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | ||||
VIBRATION | 10-500HZ | ||||
SAFETY&EMC | SAFETY STANDARD | CE RoHS | |||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | ||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | ||||
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | ||||
EMC STANDARD | Design refer to GB9254,EN55022 Class A | ||||
DIMENSION | L159*W98*H38mm | ||||
PACKING | 0.45kg,40pcs/18kg |