Yokohma/ HP / Agilent / Keysight
4262A LCR Meter
Calibration Points Checked

Free Shipping for Domestic Buyers
30 Day Guarantee
100% Return Policy

The 4262A is in very good to excellent condition, checks all test functions and the calibration points have been checked against my standards. It is fully functional and comes with a 30 day 100% satisfaction guarantee. 

Description:

The 4262A LCR meter for component measurements uses a microprocessor to automate procedures, thus increasing the capabilities of the meter without incurring significantly greater costs. To measure the value of a passive component with this instrument, it is only necessary to select the measurement function and loss parameter - resistance (R), capacitance (C), or inductance (L), and dissipation factor (D) or quality factor (Q) - select the appropriate test frequency, and connect the component to the test terminals. The instrument automatically switches to the correct measurement range, selects the preferred circuit mode, and presents results on the 3½ digit displays in about 250 ms without any time-consuming balancing adjustments. The user, however, can have full manual control of the instrument at any time simply by pressing the appropriate front-panel pushbuttons.

  • Measurement frequencies: 
  • 120  Hz,1 kHz, 10 kHz
  • Parameter measurements
    • C - D or Q (1/D)
    • L - D or Q (1/D)
    • R (ESR)
  • C ranges
    • At 120 Hz: 1000 pF to 10 mF
    • At 1 kHz: 100 pF to 1000 µF
    • At 10 kHz: 10 pF to 100 µF
  • L ranges
    • At 120 Hz: 1000 µH to 1000 H
    • At 1 kHz: 100 µH to 100 H
    • At 10 kHz: 10 µH to 10 H
  • D ranges for both C - D, C - Q and L - D, L - Q measurements: 0.001 ~ 19.9 (two ranges)
  • Q ranges for both C - D, C - Q and L - D, L - Q measurements: 0.05 ~ 1000 (four ranges)
  • R/ESR ranges: 1000 mΩ to 10 MΩ
  • Deviation measurement: The difference between the referenced value and subsequent results in counts from -999 to 1999
  • Measurement circuit modes: Auto, Parallel, Series
  • Range modes
    • LCR - Auto, Manual (up-down)
    • DQ - Auto, Manual (step)
  • Test signal levels
    • Normal level: 1 Vrms
    • Low level: 50 mVrms (parallel capacitance mode only)
  • Offset adjustment for stray capacitance and residual inductance
    • C: up to 10 pF
    • L: up to 1 µH
  • Trigger: Internal, External, Manual
  • DC Bias
    • Internal: 1.5 V, 2.2 V, 6 V
    • External: Maximum +40 V
  • Warmup time: 15 minutes

This sale includes the meter and power cord only. The test leads are for demonstrating the spot claibration points and are not included in the sale.

Shipping will be via FedEx Ground of 21 lbs.