YOU ARE BIDDING ON ONE MISSOURI WIND
24 VOLT 440 AMP
10,000 WATT CHARGE CONTROLLER WITH
DIVERT LOAD
3 PHASE BRAKE SWITCH AND RECTIFIER
COMBO 440 amp CHARGE CONTROLLER
FOR 3 PHASE OUT PUT WIND TURBINES AND SOLAR PANELS
ALL STEEL CONSTRUCTION
1 YEAR WARRANTY
IT CAN DISCONNECT THE INCOMING POWER OR DIVERT IT.
Connect wind and solar at the same time !
Check out the video below for our other controllers
Use for 3 phase ac output wind turbines
HAS A GREEN FLASHING LIGHT THAT LETS YOU KNOW BATTERY STATUS.
RED LIGHT COMES ON WHEN IN DIVERT MODE.
Comes with 5 feet of heavy duty cables.
Comes completely prewired as shown above.
Charge controller with 600 watt divert load, 3phase 50 amp
brake switch and 70 amp 1000 volt rectifier.
(does not come with battery)
This diversion controller has most of the features of our larger controller, but is much more compact and economical due to to the fact it is specifically designed
for 24 volt systems.
Some of the key features of this controller are:
Some specifics about the points made above.
The microprocessor is the heart of the controller. It is given the battery voltage and the user changeable trip points. This information is analyzed and acted upon.
The Battery level is checked, and based on that info, the Green LED flashes or is illuminated as follows
- (One) Flash indicates the battery is less than 12 volts (12 volt system - Double for 24 etc)
- (Two) Flashes indicates the battery is 12 to 12.5V
- (Three) Flashes indicates the battery is 12.6 to 13v
- (Four) Flashes indicate the battery is 13.1 to 13.5V
- ( Five) Flashes indicates the battery is above 13.5V but less than 13.9V (Settings are adjustable)
Steady green means the battery is full.
The red LED is illuminated when the battery is being dumped at 14.5v (or the charge source diverted.)
The dump remains active for a minimum of 5 seconds, at which time it is checked by the microprocessor. If battery voltage drops below the "Dump Cancel " level, the dump is disabled, otherwise the dump is continued and rechecked every 5 seconds.
When you click the "TEST" push-button - the 5 second cycle is started (one time, unless the batteries are within the "Dump Start" and "Dump Cancel" zone.)
Settings are user changeable!! By simply turning a simple potentiometer with a small screwdriver, you can quickly adjust the trip point.
We do not mark items as gifts or under report values for customs. For International buyers it is strongly recommended to check your own countries tax practices as we do not pay your taxes, duty or customs fees.
We do not over charge for shipping. It is simply what the shipping calculator comes up with. Customs fees or taxes are not included in shipping. It is your responsibility to pay them.
MEET OUR SALES AND SHIPPING TEAM