Characteristics: | UEi C30 Smart Bell Plus Combustion Tester Meter |
Combustion analysis in real time | |
Direct CO2 measurement and no sensor replacement with EOS | |
Includes many pre-programmed fuels: Light Oil, Propane, Natural gas, Heavy Oil, and Wood |
|
Measures: | CO, CO2, Temperature |
Calculates: | O2, Excess Air, Efficiency, Net T |
5 Year Limited Warranty | |
UEi C30 Smart Bell Plus includes: | Flue Probe, Protective Boot w/ Magnet, Soft Carrying Case |
Specifications: | UEi C30 Smart Bell Plus Combustion Tester Meter | ||
Parameter | Range | Resolution | Accuracy |
Flue Temperature | 32-1112˚F (0-600˚C) | 1.0˚F | ±(2%RDG ±3.6˚F(2˚C)) |
Net Temperature2 | 32-1112˚F (0-600˚C) | 1.0˚F | ±(2%RDG ±3.6˚F(2˚C) |
Gas Measurement | |||
Carbon Monoxide (CO)1 | 1-1999ppm | 1ppm | ±5ppm <100ppm ±5%RDG >100ppm |
Carbon Dioxide (CO2)1 | 0-30% | 0.1% | ±0.2%RDG |
Oxygen2 | 0-21.0% | 0.1% | ±0.3% |
Efficiency2 | 0-99.9% | 0.1% | ±0.1%RDG |
Excess Air3 | 0-250% | 0.1% | ±0.2% |
Dimensions (approx.) | Weight | Handset | Probe |
1Lb | 7”x2”x3 1/4” | 4” stainless steel shaft nominal 36” neoprene hose |
|
Ambient Operating range | 32-104˚F, 10-90%RH non-condensing, 850-1100mmHg atmospheric pressure |
||
Battery, Battery Life | (4) AA, >8hours expected using alkaline AA cells | ||
1Using Dry Gases at STP, 2Calculated, 3Calculated assuming fuel lean combustion |