ac 220V Digital LCD Thermostat Temperature Regulator Controller Probe FOR Aquarium

  • Features : 
     

    Installation opening size:

     = 2 \* GB3 Wiring diagram

      

     

    Terminals 1 and 2: Normally opened contact of relay

    Terminals 2 and 3: Normally closed contact of relay
    Terminals 4 and 5: Temperature connection sensor

    Terminals 6 and 7: Connect the power

     

     

    ③ Electrical performance:
     
    Temperature measurement range: -9.9℃ ~ 99.9 ℃
     Temperature control range: -9.9℃ ~ 99.9℃
     Temperature measurement error: ± 0.5 ℃
     Sensor Type: NTC (10K/3435)
     Control accuracy:0. 1 ℃
     Working voltage : for detailed information of the input voltage, please see the   notes on the products

     Working current: <2W

     Relay contact point current: AC 7A/220V
     Data storage : Yes
     Working temperature: 0 ℃ ~ 50 ℃
     Storage temperature: -10 ℃ ~ 60 ℃

    ④ Key Instructions:
     1. RST: Press RST key to switch on and off, press the RST key on the power-off state once to turn on, on the power-on state, press the RST key for three seconds and hold on, then it will be off.
     2. SET:
     A: Press the SET key once to enter the temperature control setting, press ▲ or ▼ button to adjust, press ▲ or ▼ button for three seconds and hold to enter the fast adjusting mode, press the SET key again to exit setting mode.
     B: Press the SET and UP key for more than 3 seconds to enter the system menu settings, press the ▲ or ▼ key to select the adjustment menu, press SET key once to enter the appropriate parameter settings, press ▲ or ▼ to adjust the parameters needed to be modified, after being adjusted, press the RST key to exit, or exit as the system delay for 5 seconds.
     ▲: Up key
     ▼: Down key

    ⑤ Operating Instructions:
     LED Status Description:
     The WORK lights at the left side of the screen is used as working indicator lights, flashing is to indicate the delay of cooling or heating, if the LED is always on ,it indicates it is on the status of cooling or heating .
     The SET light at the left side of the screen lights is used as setting indicator lights, if the LED is always on ,it indicates it is on the status of setting.

    Function Instructions:
     Press RST key to open the thermostat, on the running status, press this key for 3 seconds, then the thermostat can be turned off.
     ◆
    Cooling, heating function:
     Cooling Mode: When the measured temperature is higher than or equal to the set value + hysteresis, the relay picks up to start the output; When the measured temperature below the set value, the relay off and close the output.
     Heating mode: When the measured temperature is higher than or equal to the set value, the relay off, turn off the output; When the measured temperature below the set value - hysteresis, the relay picks up to start the output.

    Example for Setting: If it is set to heating mode, set the temperature to 25 degrees, hysteresis is set to 5, then when the measured temperature is higher than or equal to 25 degrees, the relay is off, close the output. When the temperature is below 20 degrees, pick up the relay again, to start the output.
    Example for Setting: If it is set to cooling mode, set the temperature to 25 degrees, hysteresis is set to 5, then when the measured temperature is below 25 degrees, the relay is off, close the output. When the temperature is higher than or equal to 30 degrees, pick up the relay again, to start the output.

    Cooling, heating mode setting:
     Press the SET and UP key for more than 3 seconds to enter the menu display, the screen appears "HC" code, press the "SET" key to display the working mode, press the "▲" or "▼" to adjust the display, C means cooling mode; H means heating mode.

    Hysteresis function:
     Hysteresis setting limits the maximum interval between the opening and stopping, this machine minimum interval between the opening and stopping is 1 ℃, the maximum is 15 ℃.

    Hysteresis settings:
     Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" key adjusted to the screen, appearing "D" code, press the "SET" key to display the hysteresis set value, press "▲ "Or"▼"key to adjust the parameters.

    Temperature calibration funtion:
     When there is deviation between the measuring temperature and standard  temperature, use the temperature calibration function, make the machine  measurements value consistent with the standard temperature, the after calibration temperature= the before calibration temperature + calibration value (calibration value can be positive number, negative number, and 0) .

    Temperature calibration settings:
     Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" key adjusted to the screen, appearing "CA" code, press the "SET" key to display the temperature calibration settings, press "▲ "Or"▼"key to adjust the parameters.

    For example: When we measure the probe temperature was 25 degrees,it displays 25 degrees as the CA is 0, it displays 26 degrees as the CA is 1, it displays 24 degrees as the CA is -1. This function is generally applied when the probe can not measure directly the measured object. For example, we place the probe at the outside of a cup to measure its water temperature, we need to adjust the CA parameters because of the heat loss of the cup, so that the display temperature can be in accordance with cup temperature

    ◆ Delay Protection Funtion:
     In the cooling mode, the first power on, when the measured value above the set value + hysteresis value, the machine will not immediately start cooling, it needs to set the delay time, then the machine can run to start cooling; once the interval between two cooling is larger than the delay time, the machine immediately starts cooling, once the interval between two cooling is less than the delay time, the machine must run the remaining delay time to start cooling. The delay time is started to calculate from stopping the machine. The delay time of heating mode is as same as the cooling mode.
     Note: It is recommended that only the device that use compressor cooling can use the delay start function, the user who don't need delay start function please set this parameter to 0.

    Delay Protection Setting:
     Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" key adjusted to the screen, appearing "PT" code, press the "SET" key to display the delay setting value, then press the "▲ "or "▼"key to adjust the parameters.

    Upper and lower limit functions:
     The setting of HS and LS limit the set range of control temperature point , for example: HS is set to +15, LS is set to -10, the control temperature can only be adjusted between -10 and +15, when the control temperature to -10 then press "▼" key, the display will remain on the status of -10 and not decrease; when the control temperature to +15 then press "▲" key, the display will on the status of 15 and not incease. If the set point outside this range, it needs to firstly change the value of HS and LS, then it can be achieved

    Upper and lower limit settings:
     Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" key adjusted to the screen, appearing "HS" or "LS" code, press the "SET" key to display the upper or lower limit set value, Then press "▲" or "▼" key to adjust the parameters. HS means upper limit. LS means lower limit.

     For example: the upper and lower limits are used to limit the range of control temperature that can be set, such as: LS is 10, HS is 20, then press the SET key to adjust the temperature control, it can only be varied between 10 and 20
     

    High temperature alarm:
    If the measured temperature> AH, alarm. Thermostat alarm will sound, the display alternately shows H and the current temperature. Alarm, press any key to stop the alarm

    High temperature alarm settings:
    Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" button transferred to the screen appears "AH" code, press the "SET" key to display the high-temperature alarm settings, press "▲ "or" ▼ "key to adjust the parameters
    Low temperature alarm function:
    If the measured temperature<AL ; when the alarm. Thermostat alarm will sound, the display alternately shows L and the current temperature. Alarm, press any key to stop the alarm
    low temperature alarm settings:
    Press the SET and UP key for more than 3 seconds to enter the menu display, with "▲" or "▼" button transferred to the screen appears "AL" code, press the "SET" key to display the low temperature alarm settings, press "▲ "or" ▼ "key to adjust the parameters

    ◆ Menu code selection:
     

    ◆ Menu code selection:

    Symbol

    Details

    Setting range

    Factory settings

    Units

    HC

    Heating / cooling

    H/C

    C

     

    D

    Hysteresis

    0.115

    1.0

    LS

     The minimum set limit

    -9.999.9

    -9.9

    HS

     The maximum set limit

    -9.999.9

    99.9

    CA

    Temperature calibration

    -5.0+5.0

    0.0

    PT

    Delay time

    010

    1

    Minutes

    AH

     

    High temperature alarm

    015

    1.0

    AL

    low temperature alarm settings

    015

    1.0

    ⑥ fault tips:
     1)When the sensor disconnected, the screen displays --- and close the heating wire
     2)When the sensor detects the temperature is below -50 degrees, the screen displays LLL
     3)When the sensor detects a temperature higher than 110 degrees, the screen displays HHH

    ⑦ Caution for using:
     ◆ Cooling, heating load must not exceed the output contact capacity, or it may result in machine damage and cause a fire.
     ◆ Various connecting wire must be well connected with the terminal, otherwise, it would result in reducing the reliability of machine.
     ◆ When connecting the wire, please separate power supply, relays, sensors, otherwise it will damage the machine.

 

  • Package
    100% Brand New
    1x ac 220V Digital LCD Thermostat Temperature Regulator Controller Probe FOR Aquarium


  • Shipping

     1. Items will be sent out within 48 hours(except weekend and holidays) after we receive the payment. All items are shipped by Singapore or HongKong Post air mail without tracking number,unless buyers pay extra money.
    2. It is estimated that package will arrive in 10-30working days. (holidays and weekends are not included) to most countries! If you donot get the items after 30 working days please email us we will Refoud or Reship.
    3. Since air mail will takes long time for delivery, if you want items urgently, you could contact us to ask shipping cost of Express mail.(such as DHL or EMS or TNT or UPS)
    4. We are not responsible for any custom duty or import thanks
    5. We only ship the item to the address listed in your paypal payment. Please make sure your shipping address is correct.
    6. If you have any request (e.g. change address), please put a note on paypal.
Country

Delivery Time

Working Days (not including holiday)
5-7
8-10
11-14
15-19
20-30
>30
Working Days + Saturday + Sunday
5-9
10-14
15-20
21-25
26-30
>35
United States
Rate (item arrived)    
9%
50%
21%
13%
7%
Refund or Resend
United Kingdom
Rate (item arrived)
10%
62%
20%
3.5%
4.5%
Refund or Resend
Australia
Rate (item arrived)
23%
50%
13%
8%
6%
Refund or Resend
France
Rate (item arrived)
1.5%
20.5%
45%
23%
10%
Refund or Resend
Germany
Rate (item arrived)
5.5%
25%
35%
19%
15.5%
Refund or Resend

Canada

Rate (item arrived)

0.0%

44%

35%

18%

3%

Refund or Resend

Spain
Rate (item arrived)
1.5%
25%
50%
14%
9.5%
Refund or Resend


  • Payment

    We accept Paypal only.
    Please pay within 3 days after the auction ended.
    If you pay us by e-check through PAYPAL, you have to wait till it has cleared.
    We are not responsible for any custom duty or import tax.
    you can pay via Paypal anytime, and your package will be sent out within 24 hours(except weekend and holidays) upon receiving the payment.
    Serious Buyer Only! Please place bid only if you agree with all the terms.
  • Feedback:

    1. We always leave positive feedback for our buyers.
    2. Please do not leave Negative/Neutral feedback before you contact us. If there is any problem please contact us freely,we will do our best to help you.Thanks.
    3. If we do not reply your message within 24 hours,please contact me again through ebay message or email box.

  • Return Policy:

     1. If you are not satisfied when you receive your item, please return it within 14 days for a replacement or money back. Please contact me before you return it.
    2. If you buy the item by mistake and do not want it after we've shipped it, you have to bear both shipping cost and return postage.

  •  Enquiries:

    1. If you have any questions, please contact us with ebay message, We will do our best to help you .
    2. Because we are in different time zones, please wait for our reply to your email within 24 hours. Thank you.
     

 


Powered by eBay Turbo Lister
The free listing tool. List your items fast and easy and manage your active items.