Ship it via DHL/UPS with tracking #, 3-6 working days for delivery!!!
Features
100 MHz bandwidth
- Real-time sampling rate up to 1 GSa/s, Equivalent-time sampling rate up to 50 GSa/s
- Memory Depth up to 2 Mpts
- Trigger types: Edge, Pulse, Video, Slope, Alternate
- Waveform math functions:+, -, *, /, FFT
- 6 digital frequency counter
- Supports Multi-language display and embedded online help
- Screensaver from 1 minute to 5 hours
- Digital filter and waveform recorder function
- Shortcut storage function key
- 7 inch TFT-LCD display with 800 * 480 resolution
- Multiple interfaces: USB Host, USB Device (USBTMC), LAN (VXI-11), Pass / Fail
- supports 32 parameters measurements and common mathematical
operations to speed up complex / repetitive measurements.
Specifications
Model |
SDS1102CML+ |
Bandwidth |
100 MHz |
Sample Rate (Max) |
1 GSa/s |
Channels |
2+EXT |
Memory Depth (Max) |
2 Mpts |
Trigger Types |
Edge, Pulse, Video, Slope, Alternate |
I/O |
USB Host, USB Device, LAN, Pass/Fail, |
Probe (Std) |
2 pcs passive probe, PP510 |
Display |
7 inch TFT LCD (800x480) |
Functions show
Using the long memory mode, users are able to use a higher sampling rate to capture more of the signal, and quickly zoom to focus on the area of interest.
32 parameters auto measurements and 5 Zoom Function
parameters display
Pass/Fail Function Math Function
Digital Recorder
Embedded Online Help Abundant interfaces
- Digital Oscilloscope -1
- USB Cable -1
- Quick Start-1
- Certificate of Calibration-1
- Passive Probe-2
- Quality Certificate-1
- Power Cord -1
- CD (Included User Manual and EasyScopeX software-1)
1. The oscilloscope cannot start?
First, check the power cord and power strip, check the power switch to make sure it is open (SDS1000CFL series has a power switch and a power protection switch). To judge whether the machine is powered on through checking fan’s working status, if the fan works, the machine is powered on. If everything is normal but the oscilloscope still cannot start, please contact the after sale service.
2. The screen does not appear waveform during the signal acquisition?
1) Check the connection of the probes and signals.
2) Check the connection of the signal cable and BNC.
3) Check the connection of the probes and objects.
4) Check whether the object generates signals
5) Repeat the acquisition
6) Check the trigger status
3. Waveform is appeared but not stable
1) Check the trigger source channel panel is consistent with the actual signal path.
2) Manually adjust the LEVEL trigger knob to see whether the waveform is stable.
3) Use AUTO to adjust the waveform automatically to see whether the waveform is stable
4) Adjust time base, rule out false-wave interference
4. Amplitude is not exactly
1) Check the unit of source amplitude, the default unit is Vpp of aumo measurement which means difference between the highest and lowest value, the effective value. For example, commercial power we say is 220Vrms but the Vpp is over 600V.
2) Oscilloscope is not an accurate measurement tool, according to chip digit the vertical axis will have quantization error.
5. Distortion is big when check high frenquency signal
1) Distortion is bigger when measuring signal near toplimit of oscilloscope bandwidth. Usually bandwidth should be greater than or equal to five times bandwidth of measuring signal, at that time the distortion will be very small.
2) Wrong probe will lead to distored waveform. At first bandwidth of probe should be greater than signal bandwidth, it would be best if it is greater than or euqal five times. And then, if probe is divided into 1X and 10X, 1X is usually 6MHz-10MHz, 10X is the maximum bandwidth of probe.
6. Waveform is interfered when measuring small signal
1) Siglent SDS1000 series can measure mV signal. It will turn on bandwidth limitation function at 2mV/div and filter high frequency clutter.
2) Contact clip to reference earth of signal which can reduce the distortion because of electric difference between oscilloscope and measuring signal.
1. Item will be shipped within 2 working days after full payment is received. Tracking No. will be sent to all
customers upon package shipment.
2. Our Standard Shipping Method refers to China Post unless specificially indicated in item description
above, reaching most of the countries China Post within 14 to 21 business days. We also provide Express
Shipping Service (UPS / DHL / FedEx/ EMS) options if you need it urgently.
3. Delivery time depends on destination,logistics mode and other factors. If you have not received your
shipment within 30 days from payment, please contact us. We will track the shipment and get back to you
as soon as possible with a reply. Customer`s satisfaction is our goal!
International Buyers – Please Note (from Ebay Policy):
● Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer’s responsibility.
● Please check with your country’s customs office to determine what these additional costs will be prior to bidding / buying.
International Buyers – Please Note (from Ebay Policy):
● Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer’s responsibility.
● Please check with your country’s customs office to determine what these additional costs will be prior to bidding / buying.