Our
intelligent dew point Controller LS1 is unique.
The aeration is controlled by a dew point calculation method.
This represents the physical technical optimum.
From
the measured/collected data of the two dew point sensors
(inside/outside) the optimal ventilation conditions are
calculated by the integrated processor. Due to this results the
intelligent ventilation controller LS1 activates any 230V device
like a fan, a window opener … to transport the humidified
air to the outside whenever the incoming air is drier than the
air outside. Result: The house, the cellar is drying-out.
-
Ventilator as ventilation/aeration
- Exhaust air unit with/without heat exchanging device
- Automatic electric window opener
- Air dehumidifier or electric heater/-blower
- Radiator valve
- ...
Scenario
1:
The absolute humidity in the cellar is higher than outside ->
The unit switches on the fans to transport humid air from the
cellar and to bring in dry air (drying operation). This is often
the case in spring and autumn, or at night in summer.
Scenario
2:
The absolute humidity in the cellar is lower than outside ->
The device does not switch on the fans in order not to bring in
any warm air which contains humidity that will condense on the
cold walls of the cellar. This is often the case in summer at
high daytime temperatures.
Scenario
3:
The absolute humidity in the cellar is only slightly higher than
outside -> The device can be programmed from how many percent
difference in the absolute humidity the fans should be switched
on in order to ensure an efficient operation.
Scenario
4:
The absolute humidity in the cellar is higher than outside but
the outside temperature is less than, e.g. 5° C -> The
device would switch on the fan because of the percentage difference
in the absolute humidity, but the freely programmable temperature
parameter prevents the fans from being switched on at an outside
temperature of below 0° C and cool down the cellar. This is
the case in winter.
The
complete control unit (2 pieces) is installed in a few minutes.
The main unit (control center) is easily installed with
2 screws on the wall and connected to a 230V electric circuit.
The internal sensor is already mounted in this unit. The outside
sensor is connected via cable with the main unit. Finished! Now
you can connect any device with the controller. The total ventilation
system is installed and ready to use.
24-Hour-Dispatch-Guarantee
The day we receive our payment the gauge is dispatched. We need
2-4 days for delieveries to europe.
Professional
handling
You automatically receive a note of payment and a dispatch for
the ordered articles. Each delievery is attached a bill with proven
VAT.
-
Many further measuring instruments to special prices in our shop
-