Side Channel Blowers A304 4,3 KW

The description of this item has been automatically translated. If you have any questions, please feel free to contact us.


Side channel blower, gas ring blower, gas ring compressor, side channel blower

Model

Delta_XR2

Type A304430-Z
Performance 4,3 kW
Voltage ? 380-415 Y Volt
Current 10 ? / 5,2 Y Amps
maximum volume flow 320 m³ / h
Maximum static vacuum -360 mbar
Maximum static pressure 380 mbar
Sound 73 dB (A) with an additional silencers can reduce the sound level by 10%
Packaging dimensions   L * W * H 528 x 325 x 420 mm
Weight 54 kg
Funkionsweise of side channel blower

Side channel blowers suck gas and increase the pressure through a series of vortices that are generated by centrifugal force in the side channel. Dei by rotation of the impeller, the gas is put into the individual cells into a rotary motion, while the resultant centrifugal force presses the gas to the outside in the side channel. In this way, helical turbulence where the gas is repeatedly compressed. This leads to a linear increase in pressure over the length of the side channel.

Application of:

Side channel blower, gas ring blower, gas ring compressor, side channel blower

Side channel blowers are suitable for all applications where   Pressure or under pressure is required. In suction They cover the range between fans and vacuum pumps. The rotating parts of a side channel blower does not touch the housing. So there is no friction and therefore no lubrication is necessary. The compression process takes place completely oil free and free of dust, contamination of the gas does not occur.

 Other benefits include:

easy installation,
low noise level,
vibration-free, more stable operation,
pulsation flow,
low maintenance

The performance curves refer to an air temperature of 15 ° c at an atmospheric pressure of 1013 mbar with a tolerance of +/-10%.
The total pressure difference for the on-sucking operation is for an ambient temperature up to 25 degrees Celsius.

The range of performance curves shown is valid for the continuous operation of a vacuum pump or compressor.
The units are supplied as standard for 50 and 60 Hz.
They comply with protection class IP 55   and the American UL and CSA standards.

The motors comply with the DIN standards

DIN EN 60 034 / DIN IEC 34-1 and the temperature class F

The tolerance for the frequency is +/- 2%.
The tolerance for the voltage range is +/- 10%.

Herstellernummer A304430
Marke Expodim Delta XR2