MS8260E LCR meter + multimeter AC DC V A diode buzz non contact AC dect vs FLUKE

New MASTECH MS8260E LCR meter + multimeter AC DC L C R diode/continuity check

transistor data hold with Non Contact AC Voltage detection

upgrade version for MS8222H, new 1 yr warranty + 14 day return policy

This multimeter complies with IEC 61010-1, CAT. III 1000V and CAT.600V overvoltage standards

* Environment conditions:

1000V CAT. III and 600V CAT.

Pollution degree: 2

Altitude < 2000m

Operating temperature:

0~40, 32~122(<80% RH, <10 noncondensing)

* Temperature Coefficient:

0.1´(specified accuracy) / (<18 or >28)

*  MAX. Voltage between terminals and earth ground:

750V AC rms or 1000V DC.

* Fuse Protection: mA:  fuse (FF400mA/1000V)

                 A: fuse (FF10A/500V)

*  Sample Rate: 3 times/sec for digital data.

*  Display: 3 1/2 digits LCD display. Automatic indication of functions and symbols.

*  Over Range indication: LCD will display "1".

* Low battery indication:

Non Contact AC Voltage detection

Hold the Meter so that the Meter's top is vertically and horizontally centered and contacting the conductor ,when the live voltage > 110V

(RMS),the sensing indicator will be on.

DC Voltage

Range

Resolution

Accuracy

200mV

0.1mV

±(0.5% of rdg +1 digit)

2V

1mV

20V

10mV

200V

100mV

1000V

1V

±(0.8% of rdg +2 digits)

AC Voltage

Range

Resolution

Accuracy

2V

1mV

±(0.8% of rdg +3 digits)

20V

10mV

200V

100mV

750V

1V

±(1.2% of rdg +3 digits)

 

Resistance

Range

Resolution

Accuracy

200W

0.1W

±(0.8% of rdg+3 digits)

2kW

1W

±(0.8% of rdg+1 digit)

20kW

10W

200kW

100W

2MW

1kW

20MW

10kW

±(1.0% of rdg+2 digits)

200MW

0.1MW

 

±[5.0% +10 digits]

 

 

Diode

Range

Resolution

Function


1mV

Display read approx. forward voltage of diode

Forward DC Current: approx. 1mA

Reversed DC Voltage: approx. 2.8V

Overload protection: 250Vdc or 250Vac rms.

 

Audible continuity

Range

Continuity beeper


30W

Test Current: approx. 1mA

Reversed DC Voltage: approx. 2.8V

Overload protection: 250Vdc or 250Vac rms.

 

Transistor

Range

Description

Test Condition

hFE

Display read approx. HFE value (0-1000) of transistor under test (all type).

Base Current approx. 10μA, Vce approx. 2.8V.

 

Inductance

Range

Resolution

Accuracy

20mH

0.01mH

3.0%rdg + 5dgt

200mH

0.1mH

3.0%rdg + 5dgt

2H

1mH

3.0%rdg + 5dgt

20H

10mH

3.0%rdg + 5dgt

Overload protection:  fuse (FF400mA/1000V).

 

Capacitance

Range

Resolution

Accuracy

20nF

10pF

±(4.0% of rdg+3 digits)

200nF

0.1nF

2mF

1nF

 

 DC Current

Range

Resolution

Accuracy

200mA

0.1mA

±(1.5% of rdg+1 digit)

10A

10mA

±(2.0% of rdg+5 digits)

 

Current

Range

Resolution

Accuracy

200mA

0.1mA

±(1.8% of rdg+3 digits)

10A

10mA

±(3.0% of rdg+7 digits)

Accessories

Delivered with the multimeter:

1) A pair of test leads;

2) Multi-function socket;