ut523a earth ground resistance voltage soil resistivity tester meter rs232 new y
Notes before placing orders:
  • In most cases, if choose economy shipping, shipping time is about 20 to 35 days.
  • Please contact us before opening dispution, we promise to solve every problem carefully.
  • We are NOT responsible for any custom duty or import tax.
  •  

    Description: 
     
    UT523 Series Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement. 
     

     

    Specification:

    Specifications:

    Range

    Accuracy

    Model number

     

    UT523A

    Earth resistance

    0.00Ω~19.99Ω

    ±(2%+5)

     

    20.0Ω~199.9Ω

    ±(2%+5)

     

    200Ω~1999Ω

    ±(2%+5)

     

    2.00kΩ~19.99kΩ

    ±(2%+5)

     

    20.0kΩ~210.0kΩ

    ±(2%+5)

    Soil resistivity

    0.00Ωm~99.99Ωm

    Depends on R accuracy: 

    (ρ=2πaRa:1 m~100m;

    π=3.141)

     

     

    100.0Ωm~999.9Ωm

     

    1000Ωm~9999Ωm

     

    10.00kΩm~99.99kΩm

     

    100.0kΩm~999.9kΩm

     

    1000kΩm~9000kΩm

    Earth voltage

    AC 0.00~750V

    ±(2%+5)

    Measuring frequency

    128Hz/111Hz/105Hz/94Hz(AFC)

    Features: 

    Measuring method

    Earth resistance: Rated current role changing method,

    measuring current 20mA Max

    Soil resistivity: 4-pole method(Wenner method); 

    Voltage to earth:Mean values rectifier(P(S)-ES interfaces)

    Short-circuit test current

    AC 30mA max

    Open-circuit test voltage

    AC 40V max

    Auto range

     

    Range between poles

    Can set 1m~200m

    Measuring voltage waveform

    Sine wave

    Line voltage

    AC 750V below measurement

    Low voltage measurement

    ≤7.5V

    Data hold

     

    Alarm

     

    RS232 interface

     

    Withstand voltage

    AC 3700V/rms(between circuit and shell)

    LCD backlight

     

    Data storage

    300 groups

    Auxiliary earth measurement

    Auxiliary earth resistance measurement, 

    0.00KΩ~30kΩ(100R+rC<50kΩ,100R+rP<50kΩ)

    Over-load protect

    Measure earth resistance:C(H)-E、P(S)-ES interface AC 280V/3seconds

    Interference test

    Auto identification interference signal, 

    will display “NOISE” when interference voltage is higher than 5V

    Test times

    Over 5000 times(short-circuit test, test one time, after 30 seconds and test again.

    Insulation resistance

    Over 20MΩ(500V between circuit and shell)

    General

    Power

    DC 9V ( R14S 1.5Vx 6 stand by 300hours)(Batteries are not included)

    LCD size

    128mmx75mm

    Color

    Red + Grey

    Weight

    1443g

    Size

    215mmx190mmx95mm

    Accessories

    Standard test leads, simple test leads, battery(not included), CD, RS232 cable