ebaylistingheader


This Professional Clamp Meter measure both DC and AC with clamp it also has many functions for AC measurements including resistance, HZ%, capacitance and diode test,etc.With mid-size and tear-drop shaped jaw,it is easy to use in crowded cable areas and other tight places.

1.Double molded housing

2. 4000 counts digital display with backlight

3. Electronic overload protection

4. Auto Power Off and Low Battery indication

5.Data Hold function

6.DCA Zero function

7.AC/DC Current


Data Hold Button

To freeze the LCD meter reading, press the data hold button. The data hold button is located on the left side of the meter (top button). While data hold is active, the HOLD display icon appears on the LCD. Press the data hold button again to return to normal operation.

Note: The HOLD feature will activate when the Backlight is turned on.Press the HOLD key again to exit Hold.

 

Backlight Button

The backlight function illuminates the display and is used when the ambient light to too low to permit viewing of the displayed readings. Press the    button for one second to turn the backlight on and press the button a second time to turn the backlight off.

 

Manual Ranging

The meter turns on in the autoranging mode.Press the RANGE button to go to manual ranging. Each press of the range button will step to the next range as indicated by the unitsand decimal point location.Press and hold the RANGE button for two seconds to return toautoranging.Manual ranging does not function in the AC Current, Diode and Continuity check functions.



Function

Range & Resolution

Accuracy (% of reading)

DC Current on Clamp

40.00 ADC

+ (2.8% + 10 digits)

400.0 ADC

+ (2.8 % + 5 digits)

1000 ADC

+ (3.0 % + 5 digits)

AC Current on Clamp

40.00 AAC

+ (3.0% + 10 digits)

400.0 AAC

+ (3.0 % + 5 digits)

1000 AAC

+ (3.0 % + 5 digits)

DC Voltage

400.0 mVDC

+ (0.8% + 3 digits)

4.000 VDC

+ (1.5% + 3 digits)

40.00 VDC

400.0 VDC

600 VDC

+ (2.0% + 3 digits)

AC Voltage

400.0 mVAC

+ (0.8% + 20 digits)

4.000 VAC

+ (1.8% + 5 digits)

40.00 VAC

400.0 VAC

600 VAC

+ (2.5% + 5 digits)

Resistance

400.0 O

+ (1.0% + 4 digits)

4.000K O

+ (1.5% + 2 digits)

40.00K O

400.0K O

4.000M O

+ (2.5% + 3 digits)

40.00M O

+ (3.5% + 5 digits)

Capacitance

40.00nF

+(5.0% reading + 100 digits)

400.0nF

+(3.0% reading + 5 digits)

4.000µF

+(3.5% reading + 5 digits)

40.00µF

100.0µF

+(5.0% reading + 5 digits)

Frequency

5.000Hz

+(1.5% reading + 5 digits)

50.00Hz

+(1.2% reading + 2 digits)

Sensitivity: 10Vrms min.

500.0Hz

5.000kHz

50.00kHz

100.0kHz

Duty cycle

0.5 to 99.0%

+(1.2% reading + 2 digits)

Pulse width: 100?s - 100ms, Frequency: 5.000Hz ~ 100.0kHz

Temperature

-20 to 1000 C

+(3.0% reading + 5C)

Type-K (probe accuracy not included)

-4 to 1832F

+(3.0% reading + 7F)

 


What's In The Box : 
1 x Clamp Meter
1 x 9V Battery
1 x K Temperature Probe
1 x Test Leads
1 x Manual Instruction
1 x Carry Case