The OG-7 is identical to the OG-4, but with an argon fill gas. The OG-7 also has identical pinouts and internal construction as the OG-4, but its counting speed is rated at a brisk 50 kHz.

Soviet OG-7 50kHz counter. The OG-4 and OG-7 are arguably the best choice tube for a novelty project. They are easier to drive than the single-pulse OG-3, and can be readily bought from sources like eBay in fairly large quantities.


OG-7

Decatrons two-pulse counting to work counting and computing devices for division

frequency. It is used in computer engineering, instrumentation and various counting devices

electronics.

Light color - blue. Members cold cathodes. Work in any position.

Indication is made through the dome of the container. Registration - glass, with cap (RSH5-1). Weight 70 gr

Conclusions of the electrodes: 1 - cathode is zero; 3 - an anode; 4 - podkatod 1st; 6 - podkatod 2 minutes; 8 - the cathode; 2, 5, 7 - not connected.

Basic data

The conversion factor of 10

Power supply voltage> 450 V

Firing voltage <430 V

Discharge sustaining voltage 225-265 V

The bias voltage to 36-44 in sub-katodes

The amplitude of the reset pulse voltage 130-170 V

Ignition delay time <5

Operating current 0.7-0.85 mA

These control pulses:

count rate * 0,01-50000 Hz

The amplitude of the pulse 130-150

pulse duration> 7 ms

Working hours> 500 hours

Guaranteed shelf life of 8 years

The maximum allowable parameters

The output voltage at the cathodes 15

Cathode load resistance <33k

Operating temperature -60 ... + 100 ° C

* At 1 Hz decatrons not allowed to work more than 2 hours, provided the subsequent operation at frequencies of 50 Hz and

above for an hour, the total standing time of discharge will not exceed 50 hours.


Description


Decathron two-pulse counting for operation in counting and computing devices. The color of the glow is blue. Indication is made through the canopy of the cylinder. The design - glass, with a socle (RS 5-1). Weight 70 g. Conclusions of electrodes: 1 - cathode zero; 3-anode; 4 - the first subcathode; 6 - second subcathode; 8 - cathode; 2, 5, 7, - are not connected.


 

Basic data

Parameter Conditions OG-7 Unit. amend.

Analog - - -

The conversion factor is 10 -

Power supply voltage - ≥450 V

The discharge voltage is ≤430 V

The discharge maintenance voltage is 225-265 V

The bias voltage on the subcathodes is 36-44 V

The amplitude of the reset voltage pulse is 130-170 V

Operating current - 0,7-0,85 mA

Control pulse data counting rate 0.01-50000 Hz

pulse amplitude 130-150 V

pulse width ≥7 μs

Working hours - ≥500 h


Feedback

From Buyer

Date/time

Exactly as described, fast delivery , would recommend , thank You

a*********k ( 249 )

2017-09-25

17:17:49

Excellent seller ! Good communication. A+++

s*********n ( 142 )

2017-09-14

22:14:39

Item in excellent condition, good packaging, prompt shipping.

k***********k ( 82 )

2017-06-02

12:45:56

fast delivery - tube looks great

j******r ( 458 )

2017-02-07

02:41:08

Great quality and fast shipment! Excellent ebayer!

t*************o ( 1508 )

2017-02-05

18:26:22

Well packaged and fast delivery a++++ Will definitely be doing business again

r*********i ( 128 )

2017-01-21

00:39:23

Feedback From Buyer Date/time
Positive feedback rating As described r**********n ( 1312 Red star ) 2018-02-19
20:52:06
Positive feedback rating . d********f ( 1163 Red star ) 2018-02-01
18:31:10
Positive feedback rating p m************3 ( 1127 Red star ) 2018-01-18
10:52:38
Positive feedback rating Exactly as described, fast delivery , would recommend , thank You a*********k ( 283 Turquoise star ) 2017-09-25
17:17:49
Positive feedback rating Excellent seller ! Good communication. A+++ s*********n ( 189 Turquoise star ) 2017-09-14
22:14:39
Positive feedback rating Item in excellent condition, good packaging, prompt shipping. k***********k ( 88 Blue star ) 2017-06-02
12:45:56