Model | sp12/110-3000L | sp24/110-3000L | sp48/110--3000L | sp12/220--3000L | sp24/220--3000L | sp48/220--3000L |
Continuous Power | 3000W | |||||
Surge Power | 6000W | |||||
Frequency | 50HZ±0.5HZ or 60HZ±0.5HZ | |||||
Wave Form | Pure Sine Wave | |||||
AC Regulation | THD<3%(Linear Load) | |||||
Output Efficiency | 92% | |||||
DC Voltage | DC12V | DC24V | DC48V | DC12V | DC24V | DC48V |
AC Voltage | 100VAC or 110VAC or 120VAC ±5% | 220VAC or 230VAC or 240VAC ±5% | ||||
No Load Current Draw | 2a | 1a | 0.5a | 2a | 1a | 0.5a |
DC Voltage Range | 10-15.5V | 20-31V | 40-61V | 10-15.5V | 20-31V | 40-61V |
Low Voltage Alarm | 10.5±0.5V | 21±0.5V | 42±1V | 10.5±0.5V | 21±0.5V | 42±1V |
Low Voltage Shut Down | 10±0.5V | 20±0.5V | 40±1V | 10±0.5V | 20±0.5V | 40±1V |
Over Voltage Shut Down | 15.5±0.5V | 31±0.5V | 61±1V | 15.5±0.5V | 31±0.5V | 61±1V |
Low Voltage Recovery | 13±0.5V | 24±0.5V | 48±1V | 13±0.5V | 24±0.5V | 48±1V |
Over Voltage Recovery | 14.8V±0.5V | 29V±0.5V | 59V±1V | 14.8V±0.5V | 29V±0.5V | 59V±1V |
Protection | Low Voltage/Over Voltage | LED Alarm and Automatic Recovery. | ||||
Overload | LED Alarm and Automatic Recovery. | |||||
Over Temperature | LED Alarm and Automatic Recovery. | |||||
Short Circuit | LED Alarm and Automatic Recovery. | |||||
Working Temperature | -10°- +50° | |||||
Storage Temperature | -30°- +70° | |||||
Production Size | 485*165*85(mm) | |||||
Package Size | 550*235*150(mm) | |||||
N.W/G.W | 6/ 7(kg) | |||||
Start | soft-start | |||||
Cooling Way | Intelligent Cooling Fan |
Products:
How To Use:
Nine Protection Ways:
Certification:
Applications:
Accessories and Packaging:
Photos: