Specifications:

PART NUMBER: HP961 / HB961

Display:  RED LED 0.56''

Power: AC220V, digital display 0.56''
Relay contact capacity: AC220V 3A (resistive load), the life expectancy of 10000times
frequency 30KHz (raster table 15KHz)
Display Range: -199999 to 999999, overrun "EEEEEE"
The HB961 instrument can be set magnification A magnification b, initial value of C, the decimal point dot the instrument display value = pulse input value x A. ÷ b + C
Ambient temperature: 0 ℃ ~ +50 ℃, relative humidity ≤ 85%. No corrosive gases

package:1pcs
HB961 instrument has a plus or minus count, identifiable phase counting (grating tables) two kinds of functions

Input signal: switch-level pulse (low level:-30V to +0.6 V HIGH: +4 V ~ +30 V)

can be external photoelectric tube, proximity switches, Hall sensor, angle, linear displacement grating sensors, encoder and external supply 5V

24V DC voltage or 30mA DC current
HB961 instrument current count value, counting alarm value, non-volatile count parameter values
HB961 meter relay output, two relay J1 There are three kinds of output, relay J2 11 kinds of output mode
DataCaciques
Start selling to international eBay sites.
eBay Cross Border Trade powered by ChannelEffect