Input Data |
|
Input Voltage Range |
22-65V/45-90vdc(Latest updated 22-65V) |
Max input DC voltage |
65V/90V |
Peak power tracking voltage |
25-65V/50-90V |
Output Data |
|
Max output power |
1000W |
Nominal Voltage |
110vac/230vac Auto work |
Nominal Voltage Range |
95-140v/185-265v |
Frequency Range |
47.5-51.5 for 50hz; 59.3-60.5 for 60hz |
Power Factor |
>0.95 |
Output Waveform |
Pure sine wave |
Characteristic Data |
|
MPPT Efficiency |
99% |
Over current protection |
yes |
Over temperature protection |
yes |
Reverse polarity protection |
yes |
Anti-island protection |
yes |
Stackable |
Just for AC output |
Operating temperature range |
-20 'C --- +50 'C |
Inverter inside temperature |
-20 'C --- +85 'C |
Current THD |
<5% |
Voltage THD |
<5% |
Cooling |
Fans |
Peak Inverter Efficiency |
>92% |
Warranty |
2 years |
Product Photos:
Settings Explainations on the LCD
of the 2nd Generation GTIL:
6.1. Limit Mode:External limiter and Internal limiter
are settable,
Limit mode+External limiter both
selected means work under external limiter mode.
Limit mode+Internal limiter both selected
means work under external limiter mode.
6.2.LCD back light:Select it,Lcd will always on.Unselect
it,Lcd will auto turn off after about 10s without any action on lcd
button.Press any of the button to light lcd again.
6.3.Remote
Num:while
using with wifi plug for monitoring,set by 1.While using with the WIFI-RTU(one
rtu can monitoring multiple inverters),set monitored inverter numbers.
6.4.Bat
or solar limited current mode:This function is usable while using with battery.the setted voltage will
be the cut off voltage,this means while battery discharged to the setted
voltage point or below setted point,inverter will auto disconnect from the
battery and stop operating.This can prevent the battery from over
discharged.The setted current means inverter will discharge the battery at this
current level.Mppt function of the inverter will auto invalid when working
under this setting.Set is 0.1V/step.
6.5.Reboot
voltage:This
setting voltage means while battery charged back,the inverter will auto restart
after voltage reached the setting point.It convenient the user and make the
function very flexible.Set is 0.1V/Step.
6.6.Battery
and solar limited power mode:At this working mode,cut off voltage setting is same as 6.4,and the
power setting is the maximum output power of the inverter.by this setting,user
can limit the output power manually.
7.1.The
22-65V type inverter will start up at 25V,and 45-90V type inverter will start
up at 49.5V,after start,inverter can
still work until 22v or 45v.
7.2.Current
sensor Orientation:Please check the current flow direction arrow on the sensor
before use,make sure the connection is correct.otherwise,inverter will not
start up at limit mode.
7.3.
Negative power under AC voltage means power overflow to the grid.positive means
power come from the grid.