Product Description
This item only can work for GEYA Design GYM9-AC and DC Type MCB (1A-63A) Accessory!
General
AU9: Auxiliary contact
AU9: To provide auxiliary signal, control of aux山ary circuit
AL9: Alarm contacts
AL9: When the circuit breaker for protected line fault points away, provide alarm signal
SH9: Shunt tripping device
SH9: When the control voltage exceeds the 70% - 110% of the rated voltage, the circuit breaker tripping, realize the line protection.
SH9+AU9: Shunt tripping device with auxiliary contact
SH9+AU9: Remote breaking circuit, and through the auxiliary contact to achieve control of the auxiliary circuit
UV9: Undervoltage tripping
UV9: Line voltage drop to 35% ~ 70% of the rated voltage, the circuit breaker tripping, until the voltage recovery to more than 85%, the breaker can be manually switched on.
OV9: Overvoltage trip
UV9+ 0V9:Undervoltage tripping +Overvoltage trip 3Phase4Line
PACKING
Packaging containing: 1 x munal * 1 x item you choosed.
ELECTRICAL FEATURES
AU9+AL9 Technical parameters | Voltage(AC or DC) | Working current |
AU9 AL9 | 415V AC | 3 |
240V AC | 6 | |
130V DC | 1 | |
48V DC | 2 | |
24 DC | 6 | |
SH9+AU9 and SH9 Technical parameters | Rated supplyvoltage(Us) | pull-in voltage |
SH9+AU9 SH9 |
AC/DC 220~380V | (0.7~1.1)Us |
AC/DC 110~220V | ||
AC/DC 24~48V | ||
UV9 and UV9+OV9 Technical parameters | The rated working voltage(Ue) |
Action is the voltage |
UV9 | AC 230、48V | (0.35~0.75)Ue |
DC 48V | ||
UV9+OV9 | AC 230 | Overvoltage: 275V |
Undervoltage: 170+7 V |
More Type of breakers for you consider
AC MCB | 1-4 Pole 6-125A 6kA for AC Type |
DPN MCB | 1P+N 6-40A Curve B/C for AC Type |
DC MCB | 1-4 Pole 6-125A 6kA for DC Type |
DC MCCB | 2 Pole 125-320A 8kV for DC Type |
RCD RCCB 2P Type AC | Earth Leakage Breaker 2P 25-100A 30/100/300mA AC Type |
RCD RCCB 4P Type AC | Earth Leakage Breaker 4P 25-100A 30/100/300mA AC Type |
RCD RCCB 2/4P Type A | Earth Leakage Breaker 2/4P 40/63A 100/300mA A Type |
RCD RCCB 2/4P Type AC-S | Earth Leakage Breaker 2/4P 40/63A 100/300mA AC-S Type |
RCD RCCB 2/4P Type B | Earth Leakage Breaker 2/4P 40/63A 100/300mA B Type |
RCBO 2P Type AC | Over Current&Leakage Protection 2P 10-40A 30/100/300mA AC Type |
RCBO 2P Type A | Over Current&Leakage Protection 2P 10-40A 30/100/300mA A Type |
Isolator Breaker | Isolator Breaker 1-4 Pole 63-125A |
AFDD | Arc Fault protective Fire Prevention Monitoring 40A 30mA |
MCB Recloser | Self-Reclosing Device with MCB 1-4 Pole 16-63A |
RCCB Recloser | Self-Reclosing Device with RCCB 2/4 Pole 40/63A 30/100/300mA |
We will process your order within 1 business day upon payment except holidays and weekends. Once I update tracking number, orders can not be canceled.
Economy shipping:
all economy shipping parcels do not come with tracking information or only provide tracking information when parcels are in China. If you haven't recieved your parcels after wait a long time, please contact your local post office to check your parcel by providing your recipient's name and mobile phone number.
Standard shipping:
standard shipping parcels provide whole tracking information. Suggested!
Expedited shipping:
If you need expedited shipping service, please contact me.
When you submit a return or refund application, please
1. Provide a detailed problem description and photos so that we can deal with it as soon as possible.
2. Please obey my requirments about packing of return goods. After warehouse staff recieve and check your parcel is ok, then I will refund you.
When you submit a return or refund application, please
1. Provide a detailed problem description and photos so that we can deal with it as soon as possible.
2. Please obey my requirments about packing of return goods. After warehouse staff recieve and check your parcel is ok, then I will refund you.