Optical Fiber Ranger OTDR Principle Tester Meter FTTx Network Fiber Optic
FTTH Tool Kit Visual Fault Locator
Optical Fiber Ranger is the most portable test
instrument in the industry. It adopts the OTDR technical principles and
integrates the powerful analysis software, which enables the fiber ranger
detect fiber faults location more accurate and easy.
Features:
-Portable, rugged, lightweight; Easy to use.
-More accurate testing results and better
repeatability.
-Up to 8 fiber faults can be detected in each
measurement.
-Automatic Pulse Width Control design to ensure
a convenient operation.
-Easy to identify the faults location.
-Built-in visual fault locator (VFL),
conveniently to find the faults in dead zone.
-Dust, water and shock proof, des igned for
field use
-Long battery life, up to 5000 measurements
operation.
Applications:
-Testing the distance of the fiber and identify
the faults location in the fiber link.
-Locates reflective and non-reflective breaks
in the fiber network.
-Inspection of fiber repair and maintenance.
1. Before testing, ensure that the test
connector and the interface clean OTDR (moistened with alcohol wipes to
clean) and OTDR coupled with good test line can not be connected with the
light emitting device (optical fiber can not light).
2. If you need to test the line with pigtail
connection test (butt welding or ligated, flange coupling), should pay
attention to the connection line attenuation can not be too large, otherwise
affect the test.
3. The left side of the interface simple OTDR
red light, the right to test the break interface; the interface connected to
the right of the OTDR test, and then press the power button, then press the
SCAN button, the screen display ||||||||| |||||| scroll bar, scroll
completion can be measured readings.
-The first and second step is very important,
if the test result screen is null, should pay attention to whether the steps
1 and 2 did not do.
-Wavelength: 1310/1550nm
-Fiber Type: 9/125um
-Connector Type: FC/PC
-Sensor Type: InGaAs
-Laser Peak Power: ≥60mW
-Maximum display distance:
-Reflection event: 60KM (≥1dB)
-Non-reflective event: 20KM(≥2.5dB)
-Unit of measurement: M
-Reflection time dead zone: 15M
-Distance Accuracy (Reflection Event):
±(2m+2*10-4distance)
-VFL: 650nm
-VFL power: ≥1mW
-Power Supply: 3pcs 1.5V AA alkaline
batteries(Not include)
-Battery operating time: ≥5000 measurements
-Operating temperature: -5~40℃
-Storage temperature: -10~60℃
-Humidity: 0~85% Not condensing
-Weight(Without batter): 350g