Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 1500VA 900W, RM, 2U, 15A, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART1500LCD

Maximum output: 900W / 1500VA
Typical backup time
at half load: 11.8 minutes (450 Watts)
Typical backup time
at full load: 4.4 minutes (900 Watts)
Included:
SMART1500LCD UPS. No accessories included
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 1500VA 900W LCD RM 2U 120V SMART1500LCD Manual


SMART1500LCD - Tripp Lite SmartPro 1500VA Specifications:

Input:

Rated input current (Maximum Load)

8.6A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

5-15P; Right- Angled

Input Circuit Breakers

10A

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

Individually Controllable Load Banks

Yes


Output:

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

900

Nominal Voltage Details

115v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

-18%, +8%

Output Voltage Regulation (Battery Mode)

115V (+/- 5%)

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

PWM sine wave

Nominal Output Voltage(s)
Supported

110V; 115V; 120V

Output ReceptaclesIndividually Controllable Load Banks

(8) 5-15R

Individually Controllable Load Banks

No


Battery:

Full Load Runtime (min.)

4.4 min. (900w)

Half Load Runtime (min.)

11.8 min. (450w)

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries)

Less than 4.5 hours from 10% to 90%

Internal UPS Replacement Battery Cartridge

IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SMART1500LCD UPS has no battery replacement door, please contact a local electronics repair technician to source and install a matching replacement battery; If your SMART1500LCD UPS is equipped with a battery access door, please order Tripp Lite  RBC1500  (quantity 1) replacement battery

Expandable Runtime

No


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147

Overvoltage Correction

Input voltages between 128 and 147 are reduced by 12%

Undervoltage Correction

Input voltages between 93 and 107 are boosted by 14%

Severe Undervoltage Correction

Input voltages between 75 and 92 are boosted by 30%


User Interface, Alerts & Controls:

Front Panel LCD Display

Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting;
STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load
Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS
Operating Mode Display / CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling,
Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and
Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement

Switches

ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short
tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen
configuration options

Alarm Cancel Operation

Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to
indicate low-battery status

Audible Alarm

Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD
interface (see manual)

LED Indicators

Front panel LCD display


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

870

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet 

UPS Dataline Suppression Details

168 joules; Compatible with POE applications

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description

NOT INCLUDED

Installation Form Factors Supported with Included Accessories

2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower
NO RAIL KITS ARE INCLUDED. SOLD SEPARATELY

Minimum Required Rack Depth (cm)

13.5

Minimum Required Rack Depth (inches)

13.5

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

267

Primary UPS Height (mm)

89

Primary UPS Width (mm)

438

Rack Height

2U

Shipping Dimensions (hwd / cm)

19.81 x 38.81 x 55.30

Shipping Dimensions (hwd / in.)

7.80 x 15.28 x 21.77

Shipping Weight (kg)

13.83

Shipping Weight (lbs.)

30.50

UPS Housing Material

ABS

UPS Power Module Dimensions (hwd, cm)

8.89 x 43.82 x 26.67

UPS Power Module Dimensions (hwd, in.)

3.5 x 17.25 x 10.5

UPS Power Module Weight (kg)

13.61

UPS Power Module Weight (lbs.)

30


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

Up to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

78

AC Mode Efficiency Rating (100% Load)

98%


Communications:

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 provides contact-closure notification of AC
Present (pins 1,9 connected) and AC Fail (pins 1,8 connected)

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 Serial cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

Contact closure; DB9 Serial; USB (HID enabled)