Thermo Scientific PAL HTC Accela 1 TMO AutoSampler MXY013-03A

 

Includes:

- Thermo Scientific Auto Sampler MXY013-03A with handheld control terminal

- Stack Cooler DW MC04-02

- CTC Analytics Peltier Thermostat MN 03-01

- CTC Analytics AG Power Supply MN 01-01

- CTC Analytics Valve Drive Injector MV 02-05A

 

 

Features:

Thermo Scientific Accela Autosampler features temperature-controlled sample trays (for vials or microtiter plates), injection valve, and an integrated column oven to maintain sample integrity before and during analysis. The “Total Temperature Management” system ensures the mobile phase, sample loop, injection valve, and column remain at the same temperature providing maximum retention time, duplication's and minimizing thermal broadening. Method development is easily optimized using one of the multiple injection modes which include full loop, partial loop, and no waste. The Accela systems can also be combined with Open Architecture Autosamplers (HTC and HTS autosamplers), the Accela Open Auto sampler which provides a customized open frame platform with a stack-able design and extremely low carryover.

 

 

Specifications:

 

Sample capacity:

• Six trays with 54 positions for 2 mL vials

• Six deepwell or standard microtiter-plates with 96 positions

• Six microtiter-plates with 384 positions

• Six trays with 15 positions for 10 mL vials

Thermostatted sample tray

 

• 4 to +40 °C in 0.1 °C increments Peltier element

• Temperature cooling: The specification for the stack cooler DW temperature

cooling is defined as:

TΔ = ≥14.0 °C within 60 minutes

TΔ = TRoomtemperature – TStack Cooler DW

You must reach a temperature of 14.0 °C between room temperature (22 ±2 °C) and

the stack cooler DW within 60 minutes.

The control unit and the resulting temperature display on the stack cooler DW

(display) are determinative; no comparison to an independent temperature

measurement device is necessary

SyringeSizes:

• 10, 25, 50, 100, 250, 500, 1000, 2500, and 5000 μL

• Standard DLW syringe: 100 μL

Liquid injection range

• 10–100 μL with standard 100 μL syringe

• Down to 0.1 μL with solvent sandwich technique

• Down to 0.5 μL with optional 4-port internal loop valve

• Up to 5000 μL with optional larger syringe and loop

Replicate injections

• 1–99 from one vial

Minimum sample volume

• 1 μL from a 3 μL sample in 1 mL tapered micro vial

LC injector

• Electrically actuated fast switching valve drive

• 6-port Injection valve

Unit Power Supply: 

(Input) 100-240VAC, 50-60Hz, 4A, (Output) 36VDC, 4.16A

Cooler Power Supply:

(Input) 100-240VAC, 50-60Hz, 2A, (Output) 24VDC, 4.5A

Dimensions:

Height: 1045 mm (41.1 in.)
Depth: 717.5 mm (28.3 in.)
Width: 676 mm (26.6 in.)

Weight:

Weight: 38.5 kg (84.9 lb)

 

 

 

 

 

 

 

International Diagnostic Equipment Refurbishment Protocol:

Our technicians decontaminate and clean equipment upon arrival at our facility and upon your purchase to create a neutral environment for your lab use.

Preliminary testing is then conducted on our equipment to identify potential defects. Upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction on the piece of equipment are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All of the electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your equipment performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.

Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and may include delivery insurance depending on value.

* Free 30 day Returns

* Ebay Top Rated Plus Product 

* This product is available also in different quantities and cases please ask us for details

 

International Diagnostic Equipment 

- Call or email with your questions , Hablamos Español

- Details of item must be read carefully before buying and /or requesting return

 

 

Disclaimer:

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.

 

Thermo Scientific Accela Autosampler features temperature-controlled sample trays (for vials or microtiter plates), injection valve, and an integrated column oven to maintain sample integrity before and during analysis. The “Total Temperature Management” system ensures the mobile phase, sample loop, injection valve, and column remain at the same temperature providing maximum retention time, duplication's and minimizing thermal broadening. Method development is easily optimized using one of the multiple injection modes which include full loop, partial loop, and no waste. The Accela systems can also be combined with Open Architecture Autosamplers (HTC and HTS autosamplers), the Accela Open Auto sampler which provides a customized open frame platform with a stack-able design and extremely low