this is new in the box-- the box is a bit dirty and rough from shelf wear.  200-480 vac--50/60 hz -- overload relay 20-90a



SymCom’s Model 777-HVR-KW/HP-P2 is a fully programmable electronic power monitor. It is designed to monitor and protect any 3-phase, 340-480VAC motor drawing 2-800 full load amps (external CTs are required above 90 amps). This unit’s Form C contacts are pilot duty rated at 470VA@600VAC for applications where a control power transformer (CPT) is used on a 480V system. This feature saves the cost and extra wiring associated with a CPT. It provides unsurpassed protection from faulty voltage, underload and overload conditions. The 777-HVR-KW/HP-P2 can be used in a variety of 3-phase applications and features a low power trip point (adjustable on the unit) that is desirable any time the current vs. load characteristic is non-linear or has little change. In general, this applies to small slow speed motors, small centrifugal motors and fractional horsepower motors. Low power protection can be used any time in place of undercurrent protection.

The 777-HVR-KW/HP-P2 incorporates a 3-digit LED display that is used for programming, providing real-time operational information and displaying diagnostic codes to aid in troubleshooting a fault condition. It also displays
kilowatts and horsepower on the face of the unit.

The 777-HVR-KW/HP-P2 can be used as a stand-alone product or used in a network to communicate with a PC, PLC, SCADA system, or SymCom’s Solutions Software with the help of its built-in RS-485 communications port. The 777-HVR-KW/HP-P2, in conjunction with SymCom’s CIO modules, supports several communication protocols including Modbus/RTU, Modbus/TCP, DeviceNet™ and Profibus. The units can also be connected to SymCom’s remote monitors for a simple, costeffective way to meet new requirements for arc-flash safety.

The unit’s many features include enhanced trip classes beyond the NEMA standard trip classes. The settable trip class range is 2-60, with or without jam protection, and a secondary linear trip delay can be set with a range of 0-60 seconds. If both the trip class and linear trip delay are set, the 777-HVR-KW/HP-P2 will follow the faster trip time. Another feature is the automatic dry-well recovery timer that allows the unit to automatically select a restart delay based on the last cycle’s run time. This allows the 777-HVR-KW/HP-P2 to optimize restart delay times.

The 777-HVR-KW/HP-P2 can be pre-programmed with a 9-volt battery prior to actual installation. This can save a lot of time during initial installations and avoid subsequent service calls when commissioning new projects.

 SymCom 777-HVR-KW/HP-P2 Pump Monitor Typical Application

SymCom 777-HVR-KW/HP-P2 PumpSaver Plus Technical Details