Operation:
- The manual call points provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.
- Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
- Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal(non-alarm) position manually(by hand) or by closing the station's front cover, which automatically resets the switch.
Loop design and wiring:
- The fire alarm control panel Zone wire can be connected to terminal loop(+), loop(-) unpolarized wire
- If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal loop(+),loop(-)
Installation:
- Attenteion: All wiring must conform to applicable local codes, ordinances, and regulations
Mounting indoor wall
- Attach mounting base to wall at 1.5 meter's(59in) high
- Connect field wiring to terminals
- To attach product to mounting base
- Secure product by tightening the one mounting screws in the front of the product housing
Specifications:
- Non-UL Certification Listed
- Operating voltage range: 9-28VDC Volts
- Alarm resistance: 470ohm/1W
- Operating humidity range: 10% to 93% relative humidity, non-condensing
- Operating temperature range: -10℃~50℃ (14℉~122℉)
- Dimensions (LxWxH): 140x104x45mm / 5.51"x4.09"x1.77"
- Net Weight: 220g / 0.44lb
Package:
- 1 x Fire alarm call point
- 2 x Keys
- 1 x English manual