NanoVNA VNA HF VHF UHF UV Vector Network Analyzer Antenna Analyzer + PC Software


Description

  • Function:

    NanoVNA Mini Vector Network Analyzer Operating InstructioNS

    About

    NanoVNA is very tiny handheld Vector Network Analyzer (VNA). It is standalone with lcd display, portable device with battery. This project aim to provide an RF gadget but useful instrument for enthusiast.The default firmware main function is used for antenna performance measurement. If you need more test functions, please update the

    firmware to "nanoVNA_900_4ch.dfu"

    Technical data:

    - Display: 2.8 inch TFT (320 x240)

    - Power supply: built-in lithium battery

    - Measurement range: 50KHz-900MHz (default firmware)

    - RF output: -13dbm (maximum -9dbm)

    - Port SWR: < 1.1

    - Display: 2.8 inch TFT (320 x240)

    - Size: 54mm x 85.5mm x 11mm

    - Weight: 63 grams

    - Full set of accessories: main unit / 1 set, 3 SMA male calibration parts Set the frequency range (STIMULUS>START/STOP or CENTER/SPAN)

    Calibration (CAL)

    Select display format and channel (DISPLAY)

    Save (SAVE)

    You can change the display format and channel selection at any time. In the normal test mode, tap the right

    area of the screen or press the dial switch to call up the menu.Tap the screen or turn the wheel switch to select a menu item.

    The unit is in the initial state (no data is stored in 0)

    Scan range 50KHz  ̄ 300MHz (50KHz  ̄ 900MHz if it is 900M firmware)

    Track 1: LOGMAG CH0 (reflection) (default firmware)

    Track 2: SMITH CH0 (reflection) (default firmware)

    Track 3: LOGMAG CH1 (pass) (requires flash nanoVNA_900_4ch.dfu firmware)

    Track 4: CH1 stage (pass) (requires flash nanoVNA_900_4ch.dfu firmware)

    -Mark 1: Open

    Not calibrated.

    We will test before shipment and calibrate the directly connected SMA port. The calibration data is stored in state 0 and the next time it is turned into state 0 data.

    calibration:

    Calibration with the specified mechanical calibration requires three loads: open, short and load.The calibration data is saved as user calibration data. It can be saved to status 0 and can be automatically loaded at the next power�on. It can be saved to status 1-4 and can be loaded via the RECALL menu. Click the CAL→CALIBRATE menu to open the calibration interface, then connect open, shortAnd load three loads, and click on the menu corresponding to calibrate port 0. This unit comes with a simple calibration kit. For the male calibration unit, S is short-circuited (SHORT), L is loaded with (LOAD) 50 ohm load, and internal is open (OPEN). For the female calibration part, the short circuit (SHORT) is used for short-circuiting the solder on the back, the (LOAD) 50 ohm load is applied to the two 100 ohm resistors, and the open circuit (OPEN) is used for the open circuit.Isolation calibration of port 1 requires two load loads to connect port 0 and port 1 for

    best isolation. Usually the user has only one set of calibration loads for port 0. When there is only one load calibration piece, simply connect the loadcalibration piece. To port 1, port 0 remains open and then press ISOLN tocalibrate. The pass-through calibration for port 1 requires only the RF cableto be used to connect port 0 and port 1 and then press the THRU menu tocalibrate.After the calibration is completed, press the DONE button to pop up thesave interface to select the desired state for saving.After the calibration is completed, you can connect the three calibration pieces to port 0 again.Check whether the calibration is correct through the SMITH diagram. The correct calibration should be: when the connection is open, the curve should be concentrated on the far right side of the SMITH circle. When the connection is short, The curves should all be centered on the leftmost side of the SMITH circle. When connecting LOAD, the curves should be concentrated in the middle of the SMITH circle. Connect port 0 and port 1 using an RF cable and see that the S21 curve error should not exceed 0.5 dB. If the calibration data is found to be abnormal, it should be recalibrated.|If calibration has been applied, the CAL status is displayed on the left side of the main screen. C * is the state in which

    the unsaved calibration value is applied (this value will disappear after restart). C0 ~ C4 0 to 4 means that the

    saved calibration value has been applied to one of the save locations. Save is not saved When you save by operation, it changes to this state. C Each character shown below indicates that the following calibration term has been

    applied:

    D: Direction,

    R: Reflection Tracking,

    S: Source Match,

    T: Transmission Tracking,

    X: Isolation,

    C* Note: nanoVNA_300_4ch.dfu

    nanoVNA_900_4ch.dfu

    Both firmwares have the above C* functions. The factory default firmware cancels this feature!


    Select the display channel and display type:

    Through the menu's DISPLAY→TRACE item, you can choose to open or close the corresponding display channel.The color of the channel is the same as the color of the interface curve. The display channel of the last operation is the active tracking channel.

    The FORMAT, SCALE, CHANNEL operations of the menu

    are valid for this 

    Package Included:

    1PCS XNanoVNA VNA HF VHF UHF UV Vector Network Analyzer Antenna Analyzer + PC Software

Shipping
  • Item will be shipped within 24 -48 hours after full payment is received.
  • Normally the shippment to worldwide is used to take 15 to 30 business days, exclude Sat & Sun.
Payment
  • We accept PayPal only.
  • Payment must be received in 7 business days of auction closing.
  • Please leave note for your special request (e.g. Colors or Size) in ebay note when you pay the order.
  • Any special request cannot be accepted after 24 hours of payment,because most of orders will be processed instantly and same day dispatched.
Contact Us
  • If you have any questions, please feel free to email our servicer ,and we will reply you ASAP. If no response within 24 Hours, please check the spam of mail box or kindly re-send it to us.
  • We greatly appreciate your POSITIVE feedback. Please do NOT leave negative or neutral feedback without any contact. If you haven't received item in 45 days, please contact us and we will arrange refund or resend


Feedback 
  • We care about our valued buyers, if you have any questions, our Customer Service staffs will be very glad to help you. We try our best to reply your email as soon as possible, please kindly allow 24 hours(working day) for us to response. Thank you.
  • We greatly appreciate your POSITIVE feedback. Please do NOT leave negative or neutral feedback without any contact.
DataCaciques