Expedit int'l shipping for EMS (US, Europe, Australia, CA) it usually takes 6~14 business days. It can be Customs clearance delays. It can be delay because insufficient flight and customs process for entry through New York airport than other airport. Unfortunately, Economy Shipping is not supported by USPS. ◆ ◆ ◆ Package Include : 1 Qty Condition : NEW Length : 1Ft |
◆ ◆ ◆
Four-wire intercom systems require one cable for intercom A and one cable for intercom B in order to interface two channels of four-wire intercom to the base station.
This interfacing is done through the intercom A and B RJ-45 type jacks on the rear of the unit.
The send(Tx) and the receive(Rx) is connected to the intercoms 4-wire input via an RJ45 connector
for interfacing with RTS Matrix and modern digital matrix intercom system.
◆ ◆ ◆
FreeSpeak Basestation 4-wire Pinout from RJ45 port is
Pin 3,6 : Audio Out + - pair
Pin 4,5 : Audio In + - pair
Clearcom DX410 pinout rj45 is same above
this cable is enable bidirectional use
Solid wire and Semi-flexible
Please reference Manual document for setup the configuration software
PLEASE DON'T CONNECT 2WIRE CABLE INCLUDE DC VOLTAGE DIRECTLY.