About THE REDUNDANT POWER UNIT (RPU)

SMC's Redundant Power Unit can supply 150 Watts of backup power to a single
SMC device (hub or switch) in the event of an AC loss or failure of an internal
power supply. Please check with SMC for information on the devices supported
by this RPU.

Features and Benefits

• Supports one SMC device
• AC line cord can draw power from a different supply circuit
• DC line cord provides backup power to the attached device

Front and Rear Panels

A Power indicator is located on the RPU's front panel. While the AC supply and DC
backup receptacles are located on the RPU's rear panel.

Installing the RPU

The RPU may be placed on a desktop or mounted in a rack.
Warming: DO NOT place the RPU on the floor as the case is not waterproof.


RPU Packing list ( Lieferumfang)

• Redundant Power Unit -provides backup power to one SMC device
• One AC Supply Power Cord -US, Continental Europe or UK
• One DC Backup Power Cord -with D-sub connectors on both ends
• One DC Backup Power Cord -with D-sub and plastic connectors
• Rack Mounting Kit -brackets and screws
• Star-head screwdriver

Desktop or Rack Mounting

You can set the RPU on a desktop or flat surface near a separate AC power source
and close to the device to which it is to supply power. To mount the RPU in a
standard ElA 19-inch rack, use the brackets and screws supplied with the RPU. Use
a cross-head screwdriver to attach the brackets to the side of the switch. Position
the RPU in the rack by lining up the holes in the brackets with the appropriate
holes on the rack. And then use the supplied screws to mount the RPU in the rack.
(Leave about two inches of space on the sides of the RPU to ensure adequate
ventilation.)

Making Connections

Caution: DO NOT connect the RPU to an AC power source until the DC power
cord has been connected to the other device (hub or switch).

1.Connect one end of the AC cord to the AC receptacle on the supported device
(hub or switch), and the other end to a grounded power outlet.

2.Use the provided star-head screwdriver to loosen the screws on the D-sub
receptacle faceplates and remove the faceplates from both the RPU and the
supported device (hub or switch).

3.Connect one end of the DC cord to the redundant power receptacle on the
other device (hub or switch), and the other end to the IEC receptacle on the
RPU

4.Connect one end of the AC cord to the AC receptacle on the RPU, and the
other end to a grounded power outlet. The Power LED on the RPU should light
up.


SPECIFICATIONS

Model Number: SMCRPU150W

Receptacle: lEC Socket 3P

Size: 22.28 x 9.1 x 4.5 cm. (8.77x 3.58x l.77 in.)

Weight: 3.97 lb. (l.80 kg)

Temperature
Operating 0° to 40°C (32° to 104°F)
Storage -40° to +85°C (-40° to 185°F)

Relative Humidity: 20% to 90%

Cooling: 2 fans

AC InputPower: 100 to 240 VAC, 50 to 60 Hz, 3.0A

DC Output Power: + 3.3 VDC @ 30Amax., +5VDC @9Amax., +12VDC @ 0.7A max.

DC Power Cable Connector: 22-pin