Introduction
Dynamic ECG Systems adopt
3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG
waveform by the PC software. It is applicable for use in medical institution and
community.
Function
1)The recorder can real-time
store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM
can greatly reduce doctor’s work.
3)With more than 10 templates(such as
atrial premature beat, ventricular premature beat, long interval, atrial
fibrillation, etc.) and many user-defined modules, which can almost distinguish
any kind of pathologic waveforms.
4)Flexible analysis channel selection
function, which ensures that any channels can be selected as the main analysis
channel.
5)Flexible atrial fibrillation analysis, which ensures that
physicians can use the whole or segmented AUTO/manual analysis, more accurate in
atrial fibrillation analysis.
6)All pacemakers(such as AAI, VVI, DDD etc.)
can be analyzed by the powerful pacemaker analysis function.
7)With many
pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”,
“Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous
pacing”, etc.
8)Single or full-lead ECG in any time bucket can be reviewed by
the fast review analysis function.
9)With analysis functions for 5-minute,
1-hour and 24-hour heart rate variability.
10)One-key print, convenient and
fast to print the reports.
11)Perfect case management function.
12)The
risk of sleep breath pause can be predicted by the unique "Sleep breath pause
syndrome"analysis function.
13)The death risk in patients with myocardial
infarction can be predicted by the "HRT" analysis function.
14)“T-Wave
alternation” is an important index to predict the malignant arrhythmia and
sudden cardiac death
Performance
Lead: 3-lead
Record time:
24-hour
Power supply: two “AA” batteries
Interface: USB2.0
Calibration
voltage: 1mV±5%
Noise level: ≤30μV
CMRR: ≥60dB
Low-frequency
characteristics: time constant≥3.2s
Scan speed: 25mm/s±5%
Polarizing
voltage: ±300mV, sensitivity: ≤±10%
Minimum measure signal: 50 µV
p-p
Accessories
Lead cable (1 set)
ECG
electrode (1 bag)
USB cable(1)
Disk(1)
Bag(1)
User
manual(1)
Physical characteristic
Dimension: 111mm(L) × 60mm(W)
× 25mm(H)
Weight: about 105g(without batteries)
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.