FAST and SAFE shipping from our office in Sydney with shipping time and tracking #
Two notices will be sent to you by email:
1. Payment received.
2. Order status: shipping time and tracking #
Display | 6000 Resolution |
Automatic low battery indicator | Automatic low battery indicator |
Battery | 3xAAA IEC LR03 |
Jaw opening | 1.45 in (37 mm) |
Dimension(LXWXH) | 6.39 in x 2.29 in x 1.20 in |
Weight | 384g (Include battery) |
Auto Range | Ohms |
Safety Rating | CE |
Operating Temperature | 14°F to 122°F (-10 °C to 50 °C) |
Storage Temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
Operating humidity | non-condensing (< 50 °F) (< 10 °C) |
Operating Altitude | 2000 Meter |
Storage Altitude | 12,000 Meter |
IP Rating | IP40 |
Vibration | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop test requirements | 1 Meter |
EMI, RFI, EMC | Not Appoint EMC >= 0.1 V/m |
Temperature coefficients | 0.1x (Reading Accuracy)/ °C |
317
319
Current AC
Range
40.00 A, 600.0 A
40.00 A, 600.0 A, 1000 A
Resolution
0.01 A, 0.1 A
0.01 A, 0.1 A, 1 A
Accuracy
1.6% ± 6 (50-60 Hz) {40 A}
2.5% ± 8 (60-500 Hz) {40 A}
1.5% ± 5 (50-60 Hz) {600 A}
2.5% ± 5 (60-500 Hz) {600 A}1.6% ± 6 (50-60 Hz) {40 A}
2.5% ± 8 (60-500 Hz) {40 A}
1.5% ± 5 (50-60 Hz) {600/1000 A}
2.5% ± 5 digit (60-500 Hz) {600/1000 A}Crest Factor add 2% into spec for CF > 2
3.0 Max @ 500 A, 2.5 Max @ 600 A
3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC Response
True-rms
True-rms
Current DC
Range
40.00 A, 600.0 A
40.00 A, 600.0 A, 1000 A
Resolution
0.01 A, 0.1 A
0.01 A, 0.1 A, 1 A
Accuracy
1.6% ± 6 (40 A)
1.5% ± 5 (600 A)1.6% ± 6 (40 A)
1.5% ± 5 (600/1000 A)Voltage AC
Range
600.0 V
600.0 V
Resolution
0.1 V
0.1 V
Accuracy
1.5% ± 5 (20-500Hz)
1.5% ± 5 (20-500Hz)
AC Response
True-rms
True-rms
Voltage DC
Range
600.0 V
600.0 V
Resolution
0.1 V
0.1 V
Accuracy
1% ± 4
1% ± 4
Resolution
Range
400.0 Ω, 4000 Ω
400.0 Ω
4000 ΩResolution
0.1 Ω, 1 Ω
0.1 Ω
1 ΩAccuracy
1% ± 5
1% ± 5
Continuity
≤ 30 Ω
≤ 30 Ω
Inrush Current
Integration Time
No
100 ms
Frequency
Range
No
5.0 - 500.0 Hz
Accuracy
No
0.5% ± 5
Trigger Level
No
10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
FAST and SAFE shipping from our office in Sydney with shipping time and tracking #
Two notices will be sent to you by email:
1. Payment received.
2. Order status: shipping time and tracking #
Display | 6000 Resolution |
Automatic low battery indicator | Automatic low battery indicator |
Battery | 3xAAA IEC LR03 |
Jaw opening | 1.45 in (37 mm) |
Dimension(LXWXH) | 6.39 in x 2.29 in x 1.20 in |
Weight | 384g (Include battery) |
Auto Range | Ohms |
Safety Rating | CE |
Operating Temperature | 14°F to 122°F (-10 °C to 50 °C) |
Storage Temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
Operating humidity | non-condensing (< 50 °F) (< 10 °C) |
Operating Altitude | 2000 Meter |
Storage Altitude | 12,000 Meter |
IP Rating | IP40 |
Vibration | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop test requirements | 1 Meter |
EMI, RFI, EMC | Not Appoint EMC >= 0.1 V/m |
Temperature coefficients | 0.1x (Reading Accuracy)/ °C |
|
| 317 | 319 |
Current AC | Range | 40.00 A, 600.0 A | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ± 6 (50-60 Hz) {40 A} | 1.6% ± 6 (50-60 Hz) {40 A} | |
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | |
AC Response | True-rms | True-rms | |
Current DC | Range | 40.00 A, 600.0 A | 40.00 A, 600.0 A, 1000 A |
Resolution | 0.01 A, 0.1 A | 0.01 A, 0.1 A, 1 A | |
Accuracy | 1.6% ± 6 (40 A) | 1.6% ± 6 (40 A) | |
Voltage AC | Range | 600.0 V | 600.0 V |
Resolution | 0.1 V | 0.1 V | |
Accuracy | 1.5% ± 5 (20-500Hz) | 1.5% ± 5 (20-500Hz) | |
AC Response | True-rms | True-rms | |
Voltage DC | Range | 600.0 V | 600.0 V |
Resolution | 0.1 V | 0.1 V | |
Accuracy | 1% ± 4 | 1% ± 4 | |
Resolution | Range | 400.0 Ω, 4000 Ω | 400.0 Ω |
Resolution | 0.1 Ω, 1 Ω | 0.1 Ω | |
Accuracy | 1% ± 5 | 1% ± 5 | |
Continuity |
| ≤ 30 Ω | ≤ 30 Ω |
Inrush Current | Integration Time | No | 100 ms |
Frequency | Range | No | 5.0 - 500.0 Hz |
Accuracy | No | 0.5% ± 5 | |
Trigger Level | No | 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A |
All the Accuracy 73 °F ± 41 °F (23 °C ± 5 °C)
This is real FLUKE made by FLUKE China.
1) FLUKE 317 Clamp Meter with battery;
2) A pair of test leads;
3) English manual;
4) Registration Information Card;
5) Original FLUKE Portable bag.
I. PAYMENTWe accept PayPal and all major credit cards, including Visa, Master Card,, American Express, Discover, etc.II. SHIPPINGWe ship by Australia Post or others ways per customer's request.We ship out product every 3 days
We have full time staff answering phone calls for technical and sales related question from 8am to 5pm AEST and reply eBay or email messages within 1 day.
Please feel free to send us messages, we are all ears.About this instrument: our company, Analog Technologies, Inc., has been designing and developing analog electronic products for 24 years.
This tester has been used and highly recommended by our electrical engineers.
Its user manual can be found online or downloaded from our company's website.
That's why we are selling it here with the confidence that you will like it as well.
Only if you are happy with our products and services then we will be happy.About us: Our company, Analog Technologies, Inc., was started as an R&D firm in January 7, 1997, in Novi, Michigan, a small town 25 miles from Detroit.
After 24 years hard working, we have established branches in San Jose, California, USA; Sydney, Australia; and Anshan, Liaoning, P.R. China.
We have 3 departments: R&D, Production and Trading.
The products sold on eBay are either produced by our own Production Department or our sub-contractor companies.
If you have any questions and/or suggestions, please contact us. Our goal is to make our customers happy and grow our company to a bigger one.