75x25x36mm AP25 Adjustable Micro Angle Precision V Block Milling Grinder Tool






Features:

    Made of high quality stainless steel, surface hardened, sturdy and durable
    Application: In the milling machine, planer, pillar drill with adjustable angle grinder and adjustments on the blade, crossed with other devices or clamping the workpiece after machining the workpiece, such as machining slope, inclined drilling and the like.
    It can be a slider indicating the continuous tilt adjustment angle, and then be fixed with screws, used to create a variety of fixed angle machining, test pieces.
    Nickel plating, rust parallelism and precision grinding of the verticality of each working face to 0.01 mm.
    This V corner block offers high accuracy and is easy to use
Specific:
Material: stainless steel
Dimensions: approx. 75 * 25 * 36mm / 3 * 1 * 1.4in
Color: As the picture shows
Use the method:
after loosening the screws, pull the V-shaped lock along the base of the guide rail rotation, looking for the target angle. 2, using the cursor principle readings, points on the main scale 1 ° degrees, cursor dividing by 10 \ '. When the "0" of the cursor is aligned with the "0" of the main scale, it means that the measuring surface A is parallel to the reference level and the reference level, B is perpendicular to the reference level.
1) when the cursor "0" to the right of the line in the main line "0" line, degrees, with the cursor "0" reads the scores with the reading of the scale to the right of the line "0" of the cursor (the reading is the same as the vernier caliper) read the degrees (°), A and B counterclockwise measuring plane (\ ') said the rotation angle.

When the "0" cursor line in the "0" line of the main scale is left, the is still read with the "0" cursor line, the score with the "0" cursor line to the left of the scale is read . Read degrees (°), the (\ ')

A and B measure the clockwise rotation angle of the surface.

(3) Adjust the angle to the target value and tighten the V-block and base.
Main technical indicators:
(1) to measure the surface parallel to the base surface and the measurement of the surface B, perpendicular to the cursor reference "0" and to the main quadrant "0" contact ratio of the greater than 3 \ ', vernier scale two ends and the main scale two 11 ° not coincidentally not exceeding 5 \ '; Vice versa, tighten the screw so that the main lines compose 0 ° and the cursor "0" after alignment, A surface and base plane parallelism measure is not greater than 0.01 mm, B measured surface and the verticality data is not greater than 0.01 mm
(2) In the fixed state, the error of indication \ 'adjustable angle indicator is not greater than ± 10 \'
Package List:
1 x Adjustable Corner Block
1 x wrench