Authentic OEM Sundance® Spas / Jacuzzi® CLEARRAY® Replacement Bulb Formerly 6472-857 Now 6472-841


This is not generic. This is an authentic OEM part directly from Sundance/Jacuzzi


Sundance® Spa XL Replacement Bulb New CLEARRAY® XL designed by Sundance® Spas. 20% larger bulb New connection port Backwards compatible - works with older model Sundance® Spas. Original Sundance® Spa Parts.

After a year the bulb must be replaced. A message will appear on the LCD display when the time allotted has expired.

In order to clear the “blb” message a new UV bulb needs to be installed and the timer must be reset.

DO NOT TOUCH THE NEW UV BULB WITH YOUR BARE HAND.

Oil on your skin will cause hot spot on the UV bulb and shorten the life of your UV bulb.

Use the provided latex glove to handle the UV bulb.

Sundance® Spas / Jacuzzi® CLEARRAY® Water Purification System on all 2012 models as a factory installed feature*. After years of both external laboratory and in-field testing Sundance® has selected a system that makes water care a breeze, even reducing the amount of sanitizing chemicals needed**. The system treats water using exclusive UV-C light technology, which means no gas, chemical, or other by-product is added to the water or produced as a result. This proven technology has a strong track record of success in hygienic and clear water driven industries, including: hospitals, pharmaceuticals, bottling & beverage, industrial and municipal water treatment, and aquariums.

• Treats 99.9% of waterborne pathogens

• Factory installed* exclusive UV-C Technology

• Up-to 50% reduction in sanitizing chemical usage**

• Easy care and maintenance with annual bulb replacement

• No harmful odors or by-products produced

• Durable stainless steel and quartz components 

Fits ALL Sundance® and Jacuzzi® models 2012+ 

Sundance® 2012+
980 Series: Kingston, Claremont®
880 Series: Maxxus®, Aspen®, CAMEO®, ALTAMAR®, CAPRI®, OPTIMA®, MARIN®, Majesta®,
780 Series : Chelsee®, Hamilton, Montclair®, Bristol, Hanover™, Dover™, Camden®, Certa®
680 Series: McKinley®, Ramona®, EDISON®, Peyton®, Prado™,Denali®, Tacoma®, Burlington®, Hawthorne®
Select Series: CONSTANCE®, Victoria
Jacuzzi® 2012+
J-585, J-575
J-495, J-480, J-470, J-465, J-445, J-425, J-415
J-385, J-375, J-365, J-355, J-345, J-335, J-325, J-315
J-280, J-275, J-245, J-235, J-225, J-215, J-210
J-LXL®, J-LX®


This bulb needs to be changed every 12 months.  You may get a "blb", 616 error on your control panel.  It is a reminder to change the bulb.

How to replace CLEARRAY® Bulb
CLEARRAY® BULB REPLACEMENT AND QUARTZ TUBE MAINTENANCE
1. Turn the breaker to the spa OFF. We recommend that you drain your spa. Disconnect the CLEARRAY® System from the controller, Figure 
2. Once the UV lamp has cooled off remove the CLEARRAY® System enclosure cover and gasket by removing the four screws. 

DANGER: NEVER REMOVE COVER WITHOUT FIRST TURNING OFF AT POWER SOURCE.