SHIPPING AND DUTY INCLUDED IN PRICE USA AND CANADA

Brand new sealed box

Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.5...143.9 m/s8...2110 m³/h0.12...35.18 m³/min
Process connectionthreaded connection G 1 internal thread
Application
InstallationAdjustable to inside pipe diameters; (38...254 mm)
Mediacompressed air
Medium temperature [°C]0...60
Pressure rating [bar]16
Pressure rating [Mpa]1.6
Pressure rating [psi]232
MAWP (for applications according to CRN) [bar]16
Electrical data
Operating voltage [V]18...30 DC; (to SELV/PELV)
Current consumption [mA]< 110
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]1
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]250; (per output)
Number of analogue outputs1
Analogue current output [mA]4...20; (scalable)
Max. load [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Measuring/setting range
Measuring rangeMeasuring/setting range; Flow monitoring; The values apply at: Ø 72 mm
Measuring range
0.5...143.9 m/s8...2110 m³/h0.12...35.18 m³/min
Display range
0...172.7 m/s0...2532 m³/h0...42.22 m³/min
Resolution
0.1 m/s2 m³/h0.02 m³/min
Set point SP
1.2...143.9 m/s18...2110 m³/h0.28...35.18 m³/min
Reset point rP
0.5...143.2 m/s6...2100 m³/h0.12...35 m³/min
Analogue start point ASP
0...107.9 m/s0...1582 m³/h0...26.38 m³/min
Analogue end point AEP
36...143.9 m/s528...2110 m³/h8.8...35.18 m³/min
In steps of
0.1 m/s2 m³/h0.02 m³/min
Volumetric flow quantity monitoring
Pulse value1...1000 x 10³
In steps of1 Nm³
Pulse length [s]0,7...2 (D = 72 mm)
Temperature monitoring
Measuring range [°C]0...60
Display range [°C]-12...72
Resolution [°C]0.2
Set point SP [°C]0.4...60
Reset point rP [°C]0.2...59.8
Analogue start point [°C]0...45
Analogue end point [°C]15...60
In steps of [°C]0.2
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value]± 1,5
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h)
Temperature monitoring
Accuracy [K]± 2,5 (Q > 2 Nm³/h)
Response times
Flow monitoring
Response time [s]0.1; (dAP = 0)
Damping process value dAP in steps [s]0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Temperature monitoring
Dynamic response T05 / T09 [s]30 (Q > 2 Nm³/h)
Software / programming
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor: Process Data Variable; Device Identification
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time [ms]5
Supported DeviceIDs
Type of operationDeviceID
Default381
Operating conditions
Ambient temperature [°C]0...60
Storage temperature [°C]-20...85
Max. relative air humidity [%]90
ProtectionIP 65
Tests / approvals
EMC
DIN EN 60947-5-9
DIN EN 61000-6-3
Vibration resistance
DIN EN 60068-2-65 g (55...2000 Hz)
MTTF [years]213
Mechanical data
Weight [g]539.5
MaterialsPBT-GF20; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts)stainless steel (316 / 1.4401); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM
Process connectionthreaded connection G 1 internal thread
Displays / operating elements
Display
Display unit4 x LED, green (Nm³/min, Nm³/h, Nm³, °C)
function display1 x LED, green
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit
Remarks
Remarks
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
D = inside pipe diameter
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A
Diagrams and graphs
final value of the measuring range referred to the internal pipe diameter