GL800 offers you better solution for gas-leak detection, no matter for electrical substations in circuit breakers and switchgear or petrochemical application.
It enables users to visualize gas leaks in real time and can quickly pinpoint the failure. With fully calibrated for temperature measurement applications, as compared to traditional inspection, it also can inspect without interruption of process and reduce inspection time as well as Spot leaks close by or meters away.
GL800 features:
◇ Cooled QWIP detector 320x256
◇ Startup time < 7 min
◇ No need to use laser
◇ 16 bit radiometric video recording
◇ 4.3" touch screen LCD & HD viewfinder
◇ Detecting gases at any background
◇ Trace leaks to source
- Gases: SF6, Ammpnia, Acetyl Chloride, Propene, Acetic Acid, Allyl Bromide, Allyl Chloride, Allyl Fluoride, Bromomethane, Chloride Dioxide, Ethyl Cyanoacrylate, Ethylene, Furan, Hydrazine, Methylsilane, Methyl Ethyl Ketone, Vinyl Cyanide, Methyl Vinyl Ketone, Tetrahydrofuran, Vinyl Ether, Trichloroethylene, Uranyl Fluoride, Vinyl Chloride, Propenal.
IMAGING PERFORMANCE | |
Field of view | 11° × 8.8°/ 24° × 18° |
Spatial resolution ( IFOV ) | 0.6 mrad |
Focus | Automatic / Manual |
Electronic zoom function | 1×~8× |
Responsivity | 0.001 ml/s |
Image frequency | 50 / 60Hz |
Detector type | Cooled detector 320×256 pixels |
Spectral range | 10.3~10.7 µm |
Startup time | <7 min |
IMAGE PRESENTATION | |
CCD camera performance | Build-in 5 million pixels digital camera |
Video output | AV |
External display | LCD with screen |
Viewfinder | Build-in TFT LCD with high resolution(800×600 pixels) |
Palette | 8 palettes |
Gemi-vision | IR image overlap with visible light image |
MEASUREMENT | |
Temperature range | -20℃~+350℃(Optional extended to -40℃~+500℃) |
Accuracy | ±1℃(0~100℃)or ±2%(>+100°C) |
Analysis | Automatic tracking Max / with temperature data; Delta T |
Emissivity correction | Variable from 0.01 to 1.0 |
VIDEO STORAGE | |
Type | Recording of 16 bit fully radiometric IR-video to SD-card |
LASER POINTER | |
Classification | Class 2 |
Type | Semiconductor AIGalnP Diode, Laser: 1 mW/635 nm red |
IMAGE STORAGE | |
Removable SD-Card | 32G |
BATTERY SYSTEM | |
Type | Li-ion, rechargeable, field replaceable |
Operating time | ≥2.5 hours continuous operation |
Charging system | 2-bay intelligent charger ( Optional: External power cable ) |
PHYSICAL CHARACTERISTICS | |
Weight (Include battery) | ≤2.4kg |
Size ( L×W×H ) | 292×148×138 ( mm ) |
ENVIRONMENTAL SPECIFICATION | |
Operating temperature range | -10℃ to +40℃ |
Storage temperature range | -40℃ to +70℃ |
Humidity | Operating and storage 10% to 95%, non-condensing |
Encapsulation | IP54,IEC 529 |
Shock | Operational: 25G, IEC 68-2-29 |
Vibration | Operational: 2.5G, IEC 68-2-6 |
LAB TESTED TO DETECT A WIDE RANGE OF GASES | |
The type of gas | Sulfur Hexafluoride,Acetyl Chloride,Acetic Acid,Allyl Bromide,Allyl Chloride, Allyl Fluoride,Ammonia (NH3),Bromomethane,Chloride Dioxide,Ethyl Cyanoacrylate, Ethylene,Furan,Hydrazine,Methylsilane,Methyl Ethyl Ketone,Vinyl Cyanide, Methyl Vinyl Ketone,Propene,Tetrahydrofuran,Vinyl Ether,Trichloroethylene, Uranyl Fluoride,Vinyl Chloride,Propenal |