▲Item Name:
6 Parameters (ECG/HR/NIBP/ SPO2 / TEMP/ RESP) Vital Signs Patient Monitor Patient Monitor For ICU, CCU, Gynecology
▲Features:
1) 10.1inch color high resolution TFT display.
2) Arbitrarily set the alarm limit, automatic sound & light alarm.
3) Anti-movement, anti-defibrillation, anti-electrosurgical interference.
4) Drug solubility calculation function, Arrhythmia analysis function.
5) Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure.
6) Widely used in the Department of internal medicine, Dental practices, obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.
7) Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR.
▲Specification:
NIBP | |
Method: Oscillometric | Adult Mode |
Mode: Manual, Auto, STAT | SYS :40 ~ 270 mmHg |
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) | DIA :10 ~ 215 mmHg |
Measuring Period in STAT Mode:5 Min | MEAN:20 ~ 235 mmHg |
Pulse Rate Range:40 ~ 240 bpm | Pediatric Mode |
Alarm Type: SYS, DIA, MEAN | SYS:40 ~ 200 mmHg |
Measuring and alarm range: | DIA:10 ~ 150 mmHg |
Adult Mode | MEAN:20 ~ 165 mmHg |
SYS :40 ~ 270 mmHg | Neonatal Mode |
DIA :10 ~ 215 mmHg | SYS:40 ~ 135 mmHg |
MEAN:20 ~ 235 mmHg | DIA:10 ~ 100 mmHg |
Pediatric Mode | MEAN:20 ~ 110 mmHg |
Alarm Type: SYS, DIA, MEAN | Overpressure Protection |
Measuring and alarm range: | Adult Mode:297±3 mmHg |
| Pediatric Mode:240±3 mmHg |
RESP | |
Method: Impedance between R-F(RA-LL) | Measuring and Alarm Range |
Differential Input Impedance:>2.5 MΩ | Adult:0 ~ 120 rpm |
Measuring Impedance Range:0.3~5.0Ω | Neo/Ped:0 ~ 150 rpm |
Base line Impedance Range:0 – 2.5 KΩ | Resolution:1 rpm |
Bandwidth:0.3 ~ 2.5 Hz | Accuracy:±2 rpm |
Resp. Rate | Apean Alarm:10 ~ 40 S |
SpO2 | |
Measuring Range: 0 ~ 100 % | Accuracy: |
Alarm Range: 0 ~ 100 % | 70% ~ 100% ±2 %, 0% ~ 69% unspecified |
Resolution: 1 % | Actualization interval: about 1 Sec. |
Pulse Rate | |
Measuring and Alarm Range:0~254bpm | Measuring and Alarm Range:0 ~ 50 °C |
Resolution:1bpm | Resolution:0.1°C |
Accuracy:±2bpm | Accuracy:±0.1°C |
I.5TEMP measurement: | Actualization interval:about 1 Sec. |
Channel:1 | Average Time Constant:< 10 Sec. |
ECG | |
Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) | HR and Alarm Range: |
Lead selection:I, II, III, avR, avL, avF, V, | Adult:15 ~ 300 bpm |
Waveform:2 ch | Neo/Ped:15 ~ 350 bpm |
Lead mode:3 Leads ( R, L, F or RA, LA, LL) | Accuracy:± 1% or ± 1bpm,which great |
Lead selection:I, II, III, | Resolution:1 bpm |
Waveform:1 ch | Sensitivity:> 200 (uV P-P) |
Gain: 2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto | Differential Input Impedance:> 5 MΩ |
▲Shipping:
1.Shipping via DHL, FedEx, UPS, and we'll provide tracking number information to you.
2.The price doesn't include importing duties, taxes or other relative charges, pls check additional custom fee with your local custom before placing your order, and all the customs clearance and duty should be balanced by buyer.
3.Normally, the handle time of your items is within 6 working days (it would be delayed in holidays) after payment received.
▲Returns & Refund Policy:
1.Customer need contact us for exchange authorization prior to returning items, if not, we're not responsible for money returning.
2.We'll replace one to your, if the items had defective after confirmed by us.
3.Buyers will pay for all return / exchange shipping & handing fees.
▲Friendly Reminder(The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE):
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item.
Business Seller Information:
Address: Shenzhen City, China.
Phone: +86-755-36978030
ZIP Code: 518000