LED Digit for Flowmeter for Flow Meter Blue Meter D
Feature:
*When it appears normal flow rate but the meter does not count, when the DISPLAY button is pressed, the meter is turned on. In this for case, the possible cause is: 1. the impeller is stuck or damaged; 2. the sealant material is wrapped around the impeller; Solution: Remove the meter and that the impeller rotates freely.
*When it occurs the flow rate is reduced and the meter does not count when the DISPLAY button is pressed, the meter is turned on. In this for case, the reasons may be caused by: 1. The meter is partially blocked by the dried liquid; 2. the minimum flow rate; Corresponding solution: remove the instrument to that the impeller rotates freely; 2. Increase the flow rate
* When the meter is not working properly, it may be due to a board failure or a button failure. The corresponding solution: replace the circuit board
Specification:
Operating 2.3-3.3V
type: 2 LRO3 batteries
Thread size: 1inch NPT
Measure accuracy: ±1%
Maximum working pressure: 20BAR
Flow 15-120L / Min
Single count: 0.00-9999.9
Total cumulative count: 0-99999
Working temperature: -10°C ~ +60°C(14°F~140°F)
Standby time: 1 year
Note:
And due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!
Package includes:
1PC Flow Meter