This lot contains KIT TO MAKE SOLAR PANEL:
36 (+ FREE extra ) Powerful String Ribbon solar cells
this is A(-) GRADE cells Which are A quality cells BUT with small/ tiny cosmetic defects on front OR back
( please review the pictures BEFORE purchasing! )
NEVER used, NEVER tabbed/soldered
36'+4' extra of Tab Wire x 2mm !!! for 40 cells needed 40' (1' per cell) ..... (will NOT need any Solder - it's already plenty of it on the wire itself )
2 (two) 6 Amp 1000V 1KV Diode Rectifiers ( Blocking Diodes )
~~~~~~~~~~~~~~~~~~~~~~~~
Solar Cell Specifications:
Average Power (Watts): 1.8 W
Average Current (Amps): 3.6 Amps
Average Voltage (Volts): 0.5 V
.......................... This numbers WILL be HIGHER under OPEN sun
These are the factory standards. The factory standard is the average number that is achieved in a laboratory under specific conditions. The numbers might differ due to your geographical location.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Tab Wire GAUGE: 0,1000MM
WIDTH: 2,0000MMMATERIAL: 62SN/36PB/2AG TINNED COPPER
US SIZE: 0.0039" X 0.0787"
SOLDER COATING THICKNESS: 414-600 MICROINCHES/SIDE ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Diodes and components which allow current to flow in just one direction. It is often recommended that a diode be fitted to prevent reverse current flow back through a solar panel at night time (dark current). However, in a 12 volt system you will actually lose more power from losses due to this blocking diode (drop of voltage of up to 0.7 volts) than you will through the solar panel at night time. With a 24 or 48 volt solar system the losses through the diode would be much lower and so it should be considered. The diode should be fitted into the positive leg of the circuit between the fuse and the battery. If more than one battery is being charged from the same panel(s) then a diode (and a fuse ) should be fitted for each battery.
One situation where diodes are essential is with bypass diodes. Here a diode is fitted across each panel (in parallel) in a multi panel set up. Most larger solar panels have bypass diodes incorporated into them. When one of the panels in the system is damaged, weak, or (most likely) in shade, then there is the risk that full current from the rest of the panels will pass through the shaded panel and cause overheating damage. Bypass diodes are not essential for 12 and 24 volt systems, but for systems over 36 volts they should always be used.
Axial Lead Silicon Rectifier Diodes
Maximum Repetitive Peak Reverse Voltage: 1000V
Maximum RMS Voltage: 700V
Maximum DC Blocking Voltage: 1000V
Maximum Average Forward Rectified Current (60Hz, resistive or inductive load. Derate current by 20% for capacitive load): 6A
Peak Forward Surge Current (8.3ms single half sine-wave superimposed on rated load-JEDEC Method): 400A
Operating Junction and Storage Temperature Range: -55° to +125°C
Maximum Forward Voltage (IF=6A): 0.95V
Maximum DC Reverse Current at Rated DC Blocking Voltage (TA=25°): 5uA
Maximum DC Reverse Current at Rated DC Blocking Voltage (TA=100°C): 400uA
Typical Junction Capacitance (VR=4V, f=1MHz): 100pF
Maximum Thermal Resistance Junction to Ambient: 10°C/W
Please check our store for
Solar cells TAB wires BUS wires FLUX pens Blocking Diodes
https://stores.ebay.com/ecoiq
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
We ship EVERY DAY Monday to Saturday!
→ Combine shipping by request
→ Ship to any country ( USPS Mail )
→ Quick response to the questions/offers (not e-Mails!!!)
→ ALWAYS add extra cells
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~