12V 24V diesel genset generator battery charger LBC2403 -1206B dynamo charger 


Description:

Designed for engine starting operation of battery charging, charging more.With constant voltage, constant current, a trickle floating, full automatic stop, short circuit, reverse connection, etc.

Selling point:

Does many sections of charging, extend battery life 30%;

Does have short circuit resistance, resistance to reverse function;

Does high reliability, can work normally in - 30 ~ 70 degrees;

Does plus: one year replacement, lifetime warranty;

Why did you choose us:

Many sections of the charging: constant voltage, constant current, a trickle charge, full automatic stop, extend battery life by 30%;

With functions of short circuit resistance, resistance to reverse;

LED charging status indication, a see will know whether they have been full of;

With charging output contact failure, can be connected to the PLC, generator controller, etc., realize charging fault alarm;

With the BOOST up voltage function, compensation winter filling dissatisfaction phenomenon;

High reliability, can work in - 30 ~ 70 degrees;

Wide input voltage range: 100-265 vac.

Use switch circuit structure, efficiency is as high as 86.7% @ 265 vac.

Six core window:

Many sections of the charging: constant voltage, constant current, a trickle charge, full automatic stop, extend battery life by 30%;

Charger has perfect resistance to short circuit and reverse connect protection, when the battery capacity is very minimal (resistance), load short circuit, or the charger connect to the mains to charge battery at the same time to start the engine at the same time, still for the constant current output current without damage, so when the battery as the starting power supply at the same time, the charger can not disconnect measures;.

For charge indicator LED charging status indication: red, light when charging, full of rear light.The green power light

With charging output interface failure, can be connected to the PLC, generator controller, such as charging fault alarm.In the low storage battery voltage, the short circuit, there is no ac power failure such as effective;

With the BOOST up voltage function, compensation winter filling dissatisfaction phenomenon;

Over temperature protection function.When the internal temperature automatic protection, return to work after being cool.Ensure the safety of the charger and battery;

Category

Project

Specification

Input Characteristic

nominal AC input voltage range

AC (100~240)V

Max. AC input voltage range

AC (95~280)V

AC frequency

50 Hz/60 Hz

No-load power consumption

<3 W

efficiency

AC 110 V

AC 220 V

>82%

>86%

Max. input active power

LBC 2405

LBC 2403

LBC 1206

LBC 1208

168 W

97 W

90 W

118 W

Max. Input current 

2.9 A

1.8 A

1 A

1.5 A

Output Characteristic

No-load output voltage

27.6 V,error ±1%

13.8 V, error ±1%

rated charging current

5 A,error ±2%

3 A,error ±2%

6 A,error ±2%

8 A,error ±2%

rated output

135 W

85 W

83 W

111 W

Alarm Output

relay contact

0.5 A/250 VAC(Only useful with B suffixes, such as LBC2405B)

Insulating Property 

insulating resistor

Input and output,input and shell both read DC500V 1min RL 500MΩ

insulating voltage

Input and output,input and shell both read AC1500V 50Hz 1min leak current IL  3.5 mA

Working Situation 

working temperature

(-30~55)°C

store humidity

(-40~85)°C

working humidity

20% RH~ 93% RH( no condensation)

storage humidity

10% RH~ 95% RH(no condensation)

weight

1.0kg

Configuration  

size

138 mm× 90 mm× 53 mm

 

 

 

LBC2403