Series | HY inverters | |
Control Mode | SPWM | |
Input Power | 220V class:220±15%, 1 Phase or 3 Phase | |
5-Digits Display & Status Indicator Lamp | Displaying frequency, current, revolution, voltage, counter, temperature, FOR or REV rotation, and fault, etc. | |
Communication Control | RS-485 | |
Working Temperature | -10~40℃ | |
Humidity | 0-95% Relative Humidity(without dew) | |
Vibration | Below 0.5G | |
Frequency Control | Range | 0.1~400.0Hz |
Accuracy | Digital: 0.1%(-10~40℃); Analog: 0.1% (25±10℃) | |
Setting Resolution | Digital: 0.1Hz; Analog: 1‰ of max. Operating frequency | |
Output Resolution | 0.1Hz | |
Operator Setting Method | Press directly ← ∧ ∨ to set. | |
Analog Setting Method | External Voltage 0-5V,0-10V,4-20mA,0-20mA. | |
Other Functions | Frequency lower limit, starting frequency, stopping frequency, three skip frequencies can be respectively set. | |
General Control | Ramp Control | Selectable 4-speed steps ramp-up and -down time (0.1-6500s). |
V/F Curve | Set V/F curve at will. | |
Torque Control | Torque increase settable by max. 10.0%. The starting torque can reach 150% at 1.0Hz. | |
Multi-Inputs | 6 multi-function input terminals for 8–speed steps control, program operation, switching of 4-speed Ramp, UP/DOWN function, counter, external emergency stop and other functions. | |
Multi-Outputs | 5 multi-output for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings. | |
Other Functions | Auto Voltage Regulation(AVR), Decelerating Stop or Coasting Stop, DC Braking, Auto Reset and Restart, Frequency Track, PLC Program Control, Traverse Control, Drawing Control、Auto Energy Saving, Carrier Adjustable (Up to 20KHz), etc. | |
Protection Functions | Overload Protection | Electronic relay protection motor drive Drive(for constant torque 150%/1 min. for the kinds of fan 120%/1min.) |
FuseProtection | When the fuse breaks , the motor will stop. | |
Over-voltage | 220V class:DC Voltage >400V
| |
Under-voltage | 220V class:DC Voltage <200V
| |
Restart After Instant Stop | Restart with Frequency Track after Instant Stop | |
Stall Protection | Stall protection in ramp operation | |
Output Short Circuit | Electrical circuit protection | |
Other Functions | Fin over-heat protection, restriction of reverse running, direct start after power on, fault reset, parameter lock PID, one-drive-more, etc. |
1* 2.2KW 220V 3HP Frequenzumrichter
hinweis | nicht nach canarias versenden |
---|---|
Current | 10A |
Eingabephase | Einzelphase/Drehstrom |
Marke | HY |
Herstellernummer | nicht zutreffend |
Model | HY02D223B |
Power | 2.2KW |
Voltage | 220V |