Loose parts belong to DIY enthusiasts for fun and special use.

Now the following things are not inculded.

20191009115807

         Do not shoot the graduation project!Do not disturb!!!

        No paper description.You need to ask for customer service.Electronic data.

  Do not measure charged elements when using. Discharge must be measured before capacitance measurement. If inadvertent measurement of live components results in failure to function properly, the front-end protection element 1N4148 can be self-detected and replaced.

 

   Note: welding and calibration processBasically no technical support!Please read the information and learn by yourself! Welding and welding waste disposal.Please try to shoot the finished product as far as possible!

If you take the matching chassis,BNC white seatchange intoPanel BNC block!

MarkingHigh quality navigation12V 1.0A adapter! Please try not to replace it!

     The program has been burned well.Restore the default and use it.No firmware and code are provided.

give6 calibration with 0.1% accuracy

resistance  40 Euro, 1K, 3k, 9K, 10K, 100K 

The chassis is not only sold! It can be bought together with a set meal, or bought after a plate.

Also please have a certain DIY based electronic enthusiasts to buy. One hundred thousand why do not shoot!Suite organization is not easy! And welding and cherishing!

         HC HP a group of red clip LC LP is a group of black folder.

           Test frequency of bridge100H 1KHZ 7.8KHZ

After welding is completed,Restore default parameters: long press "menu".MENUThe key enters the main menu.Then press the range.RNG"Enter the calibration mode.",Press again.5secondC(Zero) key,Default values will be loaded.: Z0lower Become76 Z= X.000XCan be0-10PressL (HAND)Preservation!(buzzer does not ring at this time)  That's the default.PressMENUThen Press (CLR)XSign out.Once again, a lower open circuit and a short circuit cleared can be measured.0.5%

Connect the test clamp first to clear open circuit/short circuit calibration compensation, automatic measurement mode lower, measurement clamp open circuit Press "Zero ZERO key can be swept open circuit zero test clamp short circuit Press ZERO (C) key to do short circuit zero). After startup short circuit is obviously not zero, it can clear zero in short circuit and open circuit. Also, it is necessary to reset the different test fixtures.

    If 0.3% accuracy is required, please calibrate the calibration steps independently.

          Please do not connect the chassis to the earth, and can not test the charged components.

L 0.05uh--2000h R 0.1 milliohm --20 trillion C 1p--20 micrometer method

 

Press key:

    Menu range zero manual

Switching string and Parameter Frequency