Digital Atten ADS1102CAL Storage Oscilloscope With 100 Mhz Bandwidth
ATTEN ADS1102CAL+ is a digital storage oscilloscope with 100 MHz bandwidth, sampling frequency of 1 GSa/s and 40 Kpts memory depth. Ergonomic design and good performance make ATTEN ADS1102CAL+ a reasonable choice for students, service technicians and industrial companies needing a big number of measuring equipment.

 

Features:
· 100 MHz bandwidth. 
 
· 1 GSa/s sampling rate and 50 GSa/s equivalent sampling rate. 
 
· 2 channels. 
 
· 7" color LCD. 
 
· 12 menu languages - English, French, German, Russian, Spanish, simplified Chinese, traditional Chinese, Portuguese, Japanese, Korean, Italian, Arabic. 
 
· 40 Kpts memory depth. 
 
· Trigger types: Edge, Pulse Width, Video, Slope, Alternative. 
 
· 32 parameters auto measure function. 
 
· Multilingual context help system. 
 
· Easyscope software. 
 
· Standard configuration port. 
 
o USB host: USB flash driver save/recall function and firare update. 
 
o USB device: PictBridge compatible printer and PC remote control support. 
 
o RS232, Pass/ Fail output. 
 

 

ATTEN ADS1102CAL Comparative Specifications:

Model

ADS1022CL+

ADS1042CML

ADS1062CML

ADS1102CML

ADS1102CAL+

ADS1152CML

ADS1202CML

Bandwidth

25 MHz

40 MHz

60 MHz

100 MHz

150 MHz

200 MHz

Sampling rate

500 MSa/s

1 GSa/s

Equivalent sampling rate

10 GSa/s

50 GSa/s

Memory depth

32 Kpts

2 Mpts (one channel), 1 Mpts (two channels)
CAL series: 40 Kpts (one channel), 20 Kpts (two channels)

Rise time

< 14 ns

< 8.8 ns

< 5.8 ns

< 3.5 ns

< 2.3 ns

< 1.8 ns

Input impedance

1 MΩ || 14 pF

Sec/div range

25 ns/div to 50 s/div

10 ns/div to 50 s/div

5 ns/div to 50 s/div

2.5 ns/div to 50 s/div

scan: 100 ms -50 s/div

Display

Color LCD, (480 × 234) 7

 

Technical Specifications:

Input

Input coupling

AC, DC, GND

Input impedance

DC: 1 MΩ ± 2% || 17 pF ± 3 pF
AC: 1.2 MΩ ± 2% || 17 pF ± 3 pF, < =100 mV/div
1.0 MΩ ± 2% || 17 pF ± 3 pF, >100 mV/div

Maximum input voltage

± 400 V PK-PK CATI

Probe attenuator

1×, 10×

Oscilloscope attenuator

1×, 10×, 100×, 1000×

Horizontal system

Real time sampling rate

1 Ch: 500 MSa/s, 2 Ch: 250 MSa/s (for ADS1000CL+ models)

1 Ch: 1 GSa/s, 2 Ch: 500 MSa/s (for ADS1000CML models)

1 Ch: 1 GSa/s, 2 Ch: 1 GSa/s (for ADS1202CML models)

Equivalent sampling rate

50 GSa/s

Measure display modes

main, window, window zoom, scan, x-y

Timebase accuracy

±100 ppm measured over 10 ms interval

Time window

18 div

Vertical system

Vertical sensitivity

2 mV-10 V/div at input BNC (1-2-5 order)
2 mV-5 V/div at input BNC (for ADS1202CML and ADS1000CL+ models)

Channel voltage offset range

2 mV-200 mV: ±1.6 V
206 mV-10 V: ± 40 V in fixed gain ranges & variable gain ranges

Vertical resolution

8 bit

Channels

2

BW flatness

DC-10% of rated BW: ± 1dB
10%-50% of rated BW: ± 2 dB
50%-100% of rated BW: ± 3dB

Lower frequency limit (AC -3 dB)

10 Hz (at input BNC)

Noise: Pk-Pk for 3K record

≤ 0.6 div for average of 10 Pk-Pk readings in fixed gain settings.
≤ 0.7 div for average of 10 Pk-Pk readings in variable gain settings

SFDR including harmonics

40 dB

DC gain accuracy

± 3.0%: 5 mV/div to 5 V/div in fixed gain ranges
± 4.0%: typical for 2 mV/div and variable gain ranges

DC measurement accuracy:
all gain settings 100 mV/div

± [3%X (|reading|+|offset|) +1% of |offset| +0.2 div +2 mV]
+0.2 div+2 mV]

DC measurement accuracy:
all gain settings >100 mV/div

± [3%X (|reading|+|offset|) +1% of |offset| +0.2 div+100 mV]

Math operation

+,-, *,FFT

FFT

window mode: Hanning, Hamming, Blackman, Rectangular

Bandwidth limiter

20 MHz ± 40% typical
(note: BW limited below 20 MHz ± 40% when using probe X1)

Trigger system

Trigger types

edge, pulse width, video, slope, alternative

Trigger modes

auto, normal, single

Trigger sources

Ch1-2, EXT, EXT/5, AC Line

Trigger coupling

AC, DC, LF rej, HF rej

Trigger level range

CH1, CH2: ± 6 div from center of screen
EXT: ±1.2 V
EXT/5: ± 6 V

Trigger level accuracy (typical) applicable for the signal of rising and falling time ≥ 20 ns

internal: ±(0.2 div×V/div)( within ± 4 div from center of screen)
EXT: ±(6% of setting + 40 mV)
EXT/5: ±(6% of setting + 200 mV)

Edge trigger

edge type: rising, falling, rising and falling

Pulse width trigger

trigger modes: (>,<,=) positive pulse width, (>,<,=) negative pulse width pulse width range: 20 ns-10 s

Video trigger

support signal formats: PAL/SECAM, NTSC
trigger condition: odd field, even field, all lines, line Num

Slope trigger

(>,<,=) positive slope, (>,<,=) negative slope
time:: 20 ns-10 s

Alternative trigger

CH1 trigger type: edge, pulse, video, slope
CH2 trigger type: edge, pulse, video, slope

Control panel function

Auto set

auto adjusting of the vertical, horizontal system and trigger position

Save/recall

support 2 group referenced waveforms, 20 group setups, 20 group captured waveforms internal
storage/recall function and USB flash driver storage function.

Acquisition system

Sample type

real time, equivalent time

Sample mode

sample, peak measure, average

Averages

4, 16, 32, 64, 128, 256

Measure system

Auto measurements

Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Rise time, Fall time, Freq, Period, +Wid, -Wid, +Dut, -Dut, Bwid, Phase, FRR, FRF, FFR, FFF,LRR,LRF, LFR, LFF

Cursor measurements

manual mode, track mode and auto mode

Display

Display mode

color TFT 7" diagonal

Resolution

480 × 234 pixels

Wave display mode

point, vector

Point, vector

off, 1 sec, 2 sec, 5 sec, infinite

Menu display

2 s, 5 s, 10 s, 20 s, infinite

Screen saver

1 min, 2 min, 5 min, 10 min,15 min, 30 min, 1 hour, 2 hours, 5 hours, off

Waveform interpolation

Sin(x)/x, linear

Color model

normal, invert

Interface

USB host, USB device, RS232, pass/fail output

Power supply

Input voltage

100-240 V AC, CAT II, auto selection

Frequency scope

45 Hz to 440 Hz

Power

50 V·A

General characteristics

Dimensions (L × × H), mm

399 × 148.5 × 110.5

Weight, kg

2.4

 

Package Contents:
  • Digital oscilloscope ATTEN ADS1102CAL+ (1 pc.).
  • 25 MHz oscilloscope probes (2 pcs.).
  • 1×.
  • 10×.
  • USB cable (1 pc.).
  • EU power cord (1 pc.).
  • User manual with CD (1 pc.).
  •  
    Wed, 27 Sep 2023 02:13:43 GMT 638314064234109325 724A470F9821E81CCBEC19552C85B15F


    SALES POLICY:

    Your bid is a contract: place a bid only if you're serious about buying the item. If you are the winning bidder, you will enter into a legally biding contract to purchase the item. If payment is not received within 7 days, item may be offered to the next highest bidder or relisted at the seller's sole discretion.


    RETURN POLICY :

    We offer 90 days(used) or 180 days(new) free warranty (except consumables).we stand behind every product we sell.If you're not pleased with your purchase, we'll be happy to make an exchange or refund the product price less S&H within 7 days of your purchase. For any exchange or refund, we need the original receipt or a record of the purchase in our system, and the product must be in its original condition, including the box, packaging and all accessories. Shipping and handling charges are not refundable.


    International Buyers:

    We are NOT responsible for any custom duty or import tax. However, we will try our best to minimize it.

    Wir sind NICHT für irgendeine Zollgebühr oder Importabgabe verantwortlich.

    Nous ne sommes pas responsables de tout droit de douane ni taxe d'importation.


    About US:

    We are professional EBAY sales team and lots of ebay buyers very satisfied with our services. You can enjoy top-quality product and high-quality services from us.

    payment :

    Payments

    Shipping :

    Shipping